Aksa Gas Generator APD-NG100 (100kW)

Share this product!

Aksa Gas Generator APD-NG100 (100kW)

Call for Price

SKU: APD-NG100

The AKSA APD-NG100 is a 100 kW industrial standby generator set powered by a PSI 5.7LT-CAC natural gas/LP engine paired with a Stamford alternator and a DSE 7320 digital control panel. UL2200 Listed and built to meet NFPA 110 Level 1 requirements, this dual-fuel unit delivers dependable emergency backup power for commercial and industrial facilities, and is available in open skid or fully enclosed configurations. 

Key Features 

  • 100 kW NG / 80 kW LP Gas standby power output 
  • PSI 5.7LT-CAC engine — 5.7L, 8-cylinder, V-type, 1800 RPM 
  • Stamford UCI274D alternator, multiple voltage configurations (480/277V, 240/120V, 208/120V, 600/347V) 
  • DSE 7320 MK II digital control panel, UL & NFPA 110 compatible 
  • UL2200 Listed; manufactured to ISO9001 and ISO14001:2015 standards 
  • Meets NFPA 70, 99, 110, 37 Level 1 requirements (fast start kit required) 
  • Dual-fuel capability — runs on natural gas or LP gas 
  • Available in open skid or enclosed configurations (Level 1: 76 dBA, Level 2: 72 dBA @ 7m) 
  • Standard battery charger, jacket water heater, and critical grade silencer 
  • 24 months / 2000 hours limited standby warranty 
Share:
Description
Additional Info
Reviews
Description

 

APD-NG100 product details and specifications:

General Characteristics 

  • Model Name: APD-NG100 
  • Engine Make: PSI 
  • Engine Model: 5.7LT-CAC 
  • Alternator Make: Stamford 
  • Control Panel Make & Model: DSE 7320 
  • Frequency & Speed: 60Hz, 1800rpm 
  • Enclosure Make & Model: AKSA AUL 41/42 

Genset Rating 

  • 480/277V, 0.8 PF: 100kW / 150A NG standby, 80kW / 120A LP standby 
  • 240/120V 1ph, 1.0 PF: 94kW / 391A NG standby, 80kW / 333A LP standby 
  • 208/120V, 0.8 PF: 100kW / 347A NG standby, 80kW / 277A LP standby 
  • 600/347V, 0.8 PF: 100kW / 120A NG standby, 80kW / 96A LP standby 
  • 240/120V, 0.8 PF: 97.4kW / 292.8A NG standby, 97.4kW / 292.8A LP standby 
  • EPA – Certified for Emergency Stationary Applications 

Engine Data 

  • Manufacturer: PSI 
  • Model: 5.7LT-CAC 
  • Displacement & Cylinders: 5.7L / 8 Cylinders 
  • Engine Type: V-type, 4 Cycle 
  • Engine Speed: 1800rpm 
  • Engine Standby Power NG: 122 kW 
  • Engine Standby Power LP: 111.16 kW 
  • Aspiration: Forced Induction 
  • Compression Ratio: 9.4:1 
  • Bore / Stroke: 101.6 mm / 88.4 mm 
  • Governor Type: Electronic 

Fuel System 

  • Fuel Type: NG, LP Gas / Dual Fuel 
  • Min NG Supply Pipe Size: 1-1/4" NPT 
  • Min LPG Supply Pipe Size: 3/4" 
  • Maximum EPR Rated Pressure: 6.9 kPa / 1.0 psi 
  • Max Pressure to EPR: 2.7 kPA / 11.0 inH2O 
  • Min Pressure to EPR: 1.7 kPA / 7.0 inH2O 

Fuel Consumption 

  • Standby Power (100%): 1380 cfh / 39.1 m³/hr NG, 510 cfh / 14.4 m³/hr LP 
  • Standby Power (75%): 1125 cfh / 31.8 m³/hr NG, 410 cfh / 11.6 m³/hr LP 
  • Standby Power (50%): 780 cfh / 22.1 m³/hr NG, 290 cfh / 8.21 m³/hr LP 
  • Standby Power (25%): 550 cfh / 15.5 m³/hr NG, 180 cfh / 5.1 m³/hr LP 

Cooling System 

  • Radiator Cooling System Type: Closed Circuit 
  • Coolant Capacity, engine only: 8.1 quart 
  • Cranking Temperature: 160°F 
  • Full Open Temperature: 185°F 
  • Cont. Rating Catalyst Configuration: Dual Substrate 
  • Exhaust Gas Flow at Rated Power @ 1350°F: 845.9 cfm 

Air Intake System 

  • Combustion Air Required: 262 cfm 
  • Max Intake Air Restriction (Clean Element): 1.49 kPa / 3 inH2O 
  • Air Filter Type: Dry Paper Element 

Exhaust System 

  • Type: Air cooled manifold 
  • Max. allowable back pressure: 10.2 kPa 

Lubrication System 

  • Oil Specifications: SAE 5W-30, API Rating SM or Newer 
  • Oil Pan Capacity: 5.0 Qts 
  • Oil Filter: 1, Cartridge 
  • Max Allowable Oil Temp: 250°F 

Electric System 

  • System Voltage (dc): 12V 
  • Battery Qty, Rating: 1 x 60Ah 

Alternator Data 

  • Manufacturer: Stamford 
  • Standards: BS EN 60034 
  • Control System: PMG 
  • A.V.R.: MX341 
  • Voltage Regulation: ±1% 
  • Insulation System: Class H 
  • Protection: IP23 
  • Rated Power Factor: 0.8 
  • Stator Winding: Double Layer Concentric 
  • Winding Pitch: Two Thirds 
  • Winding Leads: 12 
  • Telephone Interference: THF < 2% 
  • Waveform Distortion: No Load < 1.5% 
  • Maximum Over Speed: 2250 rev/min 

Battery Charger & Electrical System Data 

  • Manufacturer: ComAp 
  • Model: InteliCharger 
  • Input Voltage: 85V ~ 264V AC 
  • Output Voltage / Current: 13.8V Float / 4A pk 

Jacket Water Heater Data 

  • Manufacturer: Hotstart 
  • Model: TPS101GT10-000 
  • Input Voltage: 120V 
  • Power: 1000W 

Controller Data 

  • Manufacturer: DSE 
  • Model: 7320 MK II 

Controller Features & Benefits 

  • Microprocessor controlled, UL & NFPA110 Compatible 
  • License free PC Software (Non-proprietary Software) 
  • IP65 rating offers increased resistance to water ingress 
  • Modules can be integrated to building management systems 
  • Real time clock provides accurate event log 
  • Four line back-lit LCD text display 
  • Five key menu navigation, two wire start/stop at Auto mode 
  • Front panel editing with PIN protection 
  • Support up to three remote display modules 
  • Configurable timers and alarms 
  • Multiple date and timer scheduler 
  • Integral PLC editor 
  • 'Protections disabled' feature 
  • Load switching (load shedding and dummy load outputs) 
  • Fully configurable via DSE Configuration Suite PC Software 
  • SCADA monitoring via DSE Configuration Suite PC Software 

Protection 

  • Gen. Voltage – under / over 
  • Gen. Freq. – under / over 
  • Engine Speed – under / over 
  • Engine Oil Pressure – low 
  • Engine Temp – low / high 
  • Battery Voltage – low / high 
  • Weak Battery 
  • Fail to Start / Stop 
  • Charge Alternator Fail 
  • Over Current & Load (kW/kVAr) 
  • Unbalanced Load 
  • Independent Earth Fault 
  • Reverse Power 
  • Loss of Speed Signal 

Instruments 

  • Gen. Voltage (L-L/L-N) 
  • Gen. Frequency 
  • Engine Speed 
  • Oil Pressure 
  • Water Temperature 
  • Battery Voltage 
  • Run Time 
  • Phase Sequence 
  • Power Monitoring (kWh/kVAh/kVArh) 
  • Power (kWh/kVAh/kVArh) 
  • Power Factor 
  • Generator Current 
  • Generator Load (%) 
  • Earth Current 

Enclosure Features 

  • Heavy Duty Steel / Aluminum Structure 
  • E-Stop on Enclosure 
  • Control Panel Eliminated from Engine Vibrations 
  • Standard Sound Attenuation Foam 
  • Plastic Covered Corrosion Resistant Locks & Hinges 
  • Internally Mounted Exhaust System with Rain Cap 
  • Coolant Fill Cap 
  • Removable Base Frame Lifting Hooks 
  • Oil & Coolant Drain Ports 
  • Easy Access for Maintenance 

Dimensions & Weights 

  • Open Skid: 92 in (L) x 43.3 in (W) x 53.5 in (H), Dry Weight 2,700 lbs. 
  • Enclosed Level 1: 116 in (L) x 43.3 in (W) x 66 in (H), Dry Weight 3,900 lbs., Sound Pressure @ 7m: 76 dBA 
  • Enclosed Level 2: 116 in (L) x 43.3 in (W) x 82 in (H), Dry Weight 4,200 lbs., Sound Pressure @ 7m: 72 dBA 

Standard Features & Accessories 

  • UL2200 Certification 
  • Heavy Duty Steel Base Frame 
  • PMG 
  • Engine Jacket Water Heater 
  • Battery and Battery Rack 
  • Battery Charger 
  • Anti Vibration Pads between Engine/Alternator & Base Frame 
  • Critical Grade Silencer Inside Enclosure 
  • Residential Grade Silencer Set for Open Skid Sets 
  • Exhaust outlet rain cap and radiator fill cap 
  • Sound Absorb Foam Material for Enclosure 
  • Emergency Stop Button 
  • Oil Drain Valve 
  • Coolant Drain Valve 
  • Jacket Water Heater Isolation Valves 
  • Flex Fuel Lines 
  • Secondary Lock-off Valve on Baseframe 
  • Engine Manifold Cover 
  • Turbocharger Cover 
  • Protection Covers for Rotating Parts 
  • Exhaust Insulation Cover 
  • Enclosure DC Light 
  • Operations Manual 
  • 24 Months / 2000 hours Limited Standby Warranty 

Optional Accessories 

  • Main Line CB (3 / 4 Poles – 80% / 100% rated) 
  • Upsize Alternator 
  • Anti-condensation Heater 
  • Voltage Regulation ±0.5% w/MX321 AVR 
  • Gas Regulator 
  • NG / LP Auto Changeover Control System 
  • Low Gas Pressure Alarm 
  • Low Coolant Level Alarm 
  • Oil Pan Heater 
  • Oil Temperature Display on Controller 
  • Manual Speed Adjust Rheostat 
  • Manual Voltage Adjust Rheostat 
  • Remote Annunciator Panel 
  • Remote Control & Monitoring Panel 
  • Advanced SMS Messaging 
  • Control Panel Heater 
  • Battery Disconnect Switch 
  • Battery Heater 
  • Battery Charger 10/20 Amp 
  • Shunt Trip / Aux Contacts 
  • Spring Anti-vibration Isolators 
  • Automatic Transfer Panel (ATS) 
  • 5 Years / 2000 hours Limited Comprehensive Warranty 

Codes & Standards 

  • Designed and manufactured in a facility certified to ISO9001 standards 
  • Designed and manufactured in a facility certified to ISO14001:2015 standards 
  • Single source responsibility for the generator set & accessories 
  • Prototype tested and production tested according to the UL test program 
  • Meets NFPA70, 99, 110, 37 Level 1 when equipped with the necessary accessories and installed per NFPA standards (fast start kit required for NFPA110 Level 1) 

product specifications:

SpecificationValue
Model NameAPD-NG100
Engine MakePSI
Engine Model5.7LT-CAC
Alternator MakeStamford
Control Panel Make & ModelDSE 7320 MK II
Frequency & Speed60Hz, 1800rpm
Enclosure Make & ModelAKSA AUL 41/42
NG Standby Power100 kW
NG Standby Current150A (@480/277V)
LP Gas Standby Power80 kW
LP Gas Standby Current120A (@480/277V)
Rated Power Factor0.8
Engine Displacement & Cylinders5.7L / 8 Cylinders
Engine TypeV-type, 4 Cycle
Engine Speed1800 rpm
Engine Standby Power NG122 kW
Engine Standby Power LP111.16 kW
AspirationForced Induction
Compression Ratio9.4 : 1
Bore / Stroke101.6 mm / 88.4 mm
Governor TypeElectronic
Fuel TypeNG, LP Gas / Dual Fuel
Min NG Supply Pipe Size1-1/4" NPT
Min LPG Supply Pipe Size3/4"
System Voltage (DC)12V
Battery Qty, Rating1 x 60Ah
Radiator Cooling System TypeClosed Circuit
Coolant Capacity, engine only8.1 quart
Cranking Temperature160°F
Full Open Temperature185°F
Combustion Air Required262 cfm
Air Filter TypeDry Paper Element
Oil SpecificationsSAE 5W-30, API Rating SM or Newer
Oil Pan Capacity5.0 Qts
Oil Filter1, Cartridge
Max Allowable Oil Temp250°F
Alternator StandardsBS EN 60034
Alternator Control SystemPMG
Voltage Regulation± 1 %
Insulation SystemClass H
Alternator ProtectionIP23
Controller ManufacturerDSE
Controller Model7320 MK II
Jacket Water HeaterHotstart TPS101GT10-000, 120V, 1000W
Battery ChargerComAp InteliCharger, 85V~264V AC input
Open Skid Dimensions (L x W x H)92 in x 43.3 in x 53.5 in
Open Skid Dry Weight2,700 lbs.
Enclosed Level 1 Dimensions (L x W x H)116 in x 43.3 in x 66 in
Enclosed Level 1 Dry Weight3,900 lbs.
Enclosed Level 1 Sound Pressure @ 7m76 dBA
Enclosed Level 2 Dimensions (L x W x H)116 in x 43.3 in x 82 in
Enclosed Level 2 Dry Weight4,200 lbs.
Enclosed Level 2 Sound Pressure @ 7m72 dBA
CertificationsUL2200, ISO9001, ISO14001:2015, NFPA70/99/110/37 Level 1
Warranty24 Months / 2000 Hours Limited Standby

 

product related documents:

APD-NG100.pdf

Additional Info
Weight4200 lbs
Dimensions116 × 43.3 × 82 in
Reviews

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Item added to cart View Cart Checkout
Item added to wishlist View Wishlist
Item removed from wishlist