Aksa Gas Generator APD-NG100 (100kW)

Share this product!

Aksa Gas Generator APD-NG100 (100kW)

Call for Price

SKU: APD-NG100

The AKSA APD-NG100 is a 100 kW industrial standby generator set powered by a PSI 5.7LT-CAC natural gas/LP engine paired with a Stamford alternator and a DSE 7320 digital control panel. UL2200 Listed and built to meet NFPA 110 Level 1 requirements, this dual-fuel unit delivers dependable emergency backup power for commercial and industrial facilities, and is available in open skid or fully enclosed configurations. 

Key Features 

  • 100 kW NG / 80 kW LP Gas standby power output 
  • PSI 5.7LT-CAC engine — 5.7L, 8-cylinder, V-type, 1800 RPM 
  • Stamford UCI274D alternator, multiple voltage configurations (480/277V, 240/120V, 208/120V, 600/347V) 
  • DSE 7320 MK II digital control panel, UL & NFPA 110 compatible 
  • UL2200 Listed; manufactured to ISO9001 and ISO14001:2015 standards 
  • Meets NFPA 70, 99, 110, 37 Level 1 requirements (fast start kit required) 
  • Dual-fuel capability — runs on natural gas or LP gas 
  • Available in open skid or enclosed configurations (Level 1: 76 dBA, Level 2: 72 dBA @ 7m) 
  • Standard battery charger, jacket water heater, and critical grade silencer 
  • 24 months / 2000 hours limited standby warranty 
Share:
Descripción
Additional Info
Reviews
Descripción

 

APD-NG100 product details and specifications:

General Characteristics 

  • Model Name: APD-NG100 
  • Engine Make: PSI 
  • Engine Model: 5.7LT-CAC 
  • Alternator Make: Stamford 
  • Control Panel Make & Model: DSE 7320 
  • Frequency & Speed: 60Hz, 1800rpm 
  • Enclosure Make & Model: AKSA AUL 41/42 

Genset Rating 

  • 480/277V, 0.8 PF: 100kW / 150A NG standby, 80kW / 120A LP standby 
  • 240/120V 1ph, 1.0 PF: 94kW / 391A NG standby, 80kW / 333A LP standby 
  • 208/120V, 0.8 PF: 100kW / 347A NG standby, 80kW / 277A LP standby 
  • 600/347V, 0.8 PF: 100kW / 120A NG standby, 80kW / 96A LP standby 
  • 240/120V, 0.8 PF: 97.4kW / 292.8A NG standby, 97.4kW / 292.8A LP standby 
  • EPA – Certified for Emergency Stationary Applications 

Engine Data 

  • Manufacturer: PSI 
  • Model: 5.7LT-CAC 
  • Displacement & Cylinders: 5.7L / 8 Cylinders 
  • Engine Type: V-type, 4 Cycle 
  • Engine Speed: 1800rpm 
  • Engine Standby Power NG: 122 kW 
  • Engine Standby Power LP: 111.16 kW 
  • Aspiration: Forced Induction 
  • Compression Ratio: 9.4:1 
  • Bore / Stroke: 101.6 mm / 88.4 mm 
  • Governor Type: Electronic 

Fuel System 

  • Fuel Type: NG, LP Gas / Dual Fuel 
  • Min NG Supply Pipe Size: 1-1/4" NPT 
  • Min LPG Supply Pipe Size: 3/4" 
  • Maximum EPR Rated Pressure: 6.9 kPa / 1.0 psi 
  • Max Pressure to EPR: 2.7 kPA / 11.0 inH2O 
  • Min Pressure to EPR: 1.7 kPA / 7.0 inH2O 

Fuel Consumption 

  • Standby Power (100%): 1380 cfh / 39.1 m³/hr NG, 510 cfh / 14.4 m³/hr LP 
  • Standby Power (75%): 1125 cfh / 31.8 m³/hr NG, 410 cfh / 11.6 m³/hr LP 
  • Standby Power (50%): 780 cfh / 22.1 m³/hr NG, 290 cfh / 8.21 m³/hr LP 
  • Standby Power (25%): 550 cfh / 15.5 m³/hr NG, 180 cfh / 5.1 m³/hr LP 

Cooling System 

  • Radiator Cooling System Type: Closed Circuit 
  • Coolant Capacity, engine only: 8.1 quart 
  • Cranking Temperature: 160°F 
  • Full Open Temperature: 185°F 
  • Cont. Rating Catalyst Configuration: Dual Substrate 
  • Exhaust Gas Flow at Rated Power @ 1350°F: 845.9 cfm 

Air Intake System 

  • Combustion Air Required: 262 cfm 
  • Max Intake Air Restriction (Clean Element): 1.49 kPa / 3 inH2O 
  • Air Filter Type: Dry Paper Element 

Exhaust System 

  • Type: Air cooled manifold 
  • Max. allowable back pressure: 10.2 kPa 

Lubrication System 

  • Oil Specifications: SAE 5W-30, API Rating SM or Newer 
  • Oil Pan Capacity: 5.0 Qts 
  • Oil Filter: 1, Cartridge 
  • Max Allowable Oil Temp: 250°F 

Electric System 

  • System Voltage (dc): 12V 
  • Battery Qty, Rating: 1 x 60Ah 

Alternator Data 

  • Manufacturer: Stamford 
  • Standards: BS EN 60034 
  • Control System: PMG 
  • A.V.R.: MX341 
  • Voltage Regulation: ±1% 
  • Insulation System: Class H 
  • Protection: IP23 
  • Rated Power Factor: 0.8 
  • Stator Winding: Double Layer Concentric 
  • Winding Pitch: Two Thirds 
  • Winding Leads: 12 
  • Telephone Interference: THF < 2% 
  • Waveform Distortion: No Load < 1.5% 
  • Maximum Over Speed: 2250 rev/min 

Battery Charger & Electrical System Data 

  • Manufacturer: ComAp 
  • Model: InteliCharger 
  • Input Voltage: 85V ~ 264V AC 
  • Output Voltage / Current: 13.8V Float / 4A pk 

Jacket Water Heater Data 

  • Manufacturer: Hotstart 
  • Model: TPS101GT10-000 
  • Input Voltage: 120V 
  • Power: 1000W 

Controller Data 

  • Manufacturer: DSE 
  • Model: 7320 MK II 

Controller Features & Benefits 

  • Microprocessor controlled, UL & NFPA110 Compatible 
  • License free PC Software (Non-proprietary Software) 
  • IP65 rating offers increased resistance to water ingress 
  • Modules can be integrated to building management systems 
  • Real time clock provides accurate event log 
  • Four line back-lit LCD text display 
  • Five key menu navigation, two wire start/stop at Auto mode 
  • Front panel editing with PIN protection 
  • Support up to three remote display modules 
  • Configurable timers and alarms 
  • Multiple date and timer scheduler 
  • Integral PLC editor 
  • 'Protections disabled' feature 
  • Load switching (load shedding and dummy load outputs) 
  • Fully configurable via DSE Configuration Suite PC Software 
  • SCADA monitoring via DSE Configuration Suite PC Software 

Protection 

  • Gen. Voltage – under / over 
  • Gen. Freq. – under / over 
  • Engine Speed – under / over 
  • Engine Oil Pressure – low 
  • Engine Temp – low / high 
  • Battery Voltage – low / high 
  • Weak Battery 
  • Fail to Start / Stop 
  • Charge Alternator Fail 
  • Over Current & Load (kW/kVAr) 
  • Unbalanced Load 
  • Independent Earth Fault 
  • Reverse Power 
  • Loss of Speed Signal 

Instruments 

  • Gen. Voltage (L-L/L-N) 
  • Gen. Frequency 
  • Engine Speed 
  • Oil Pressure 
  • Water Temperature 
  • Battery Voltage 
  • Run Time 
  • Phase Sequence 
  • Power Monitoring (kWh/kVAh/kVArh) 
  • Power (kWh/kVAh/kVArh) 
  • Power Factor 
  • Generator Current 
  • Generator Load (%) 
  • Earth Current 

Enclosure Features 

  • Heavy Duty Steel / Aluminum Structure 
  • E-Stop on Enclosure 
  • Control Panel Eliminated from Engine Vibrations 
  • Standard Sound Attenuation Foam 
  • Plastic Covered Corrosion Resistant Locks & Hinges 
  • Internally Mounted Exhaust System with Rain Cap 
  • Coolant Fill Cap 
  • Removable Base Frame Lifting Hooks 
  • Oil & Coolant Drain Ports 
  • Easy Access for Maintenance 

Dimensions & Weights 

  • Open Skid: 92 in (L) x 43.3 in (W) x 53.5 in (H), Dry Weight 2,700 lbs. 
  • Enclosed Level 1: 116 in (L) x 43.3 in (W) x 66 in (H), Dry Weight 3,900 lbs., Sound Pressure @ 7m: 76 dBA 
  • Enclosed Level 2: 116 in (L) x 43.3 in (W) x 82 in (H), Dry Weight 4,200 lbs., Sound Pressure @ 7m: 72 dBA 

Standard Features & Accessories 

  • UL2200 Certification 
  • Heavy Duty Steel Base Frame 
  • PMG 
  • Engine Jacket Water Heater 
  • Battery and Battery Rack 
  • Battery Charger 
  • Anti Vibration Pads between Engine/Alternator & Base Frame 
  • Critical Grade Silencer Inside Enclosure 
  • Residential Grade Silencer Set for Open Skid Sets 
  • Exhaust outlet rain cap and radiator fill cap 
  • Sound Absorb Foam Material for Enclosure 
  • Emergency Stop Button 
  • Oil Drain Valve 
  • Coolant Drain Valve 
  • Jacket Water Heater Isolation Valves 
  • Flex Fuel Lines 
  • Secondary Lock-off Valve on Baseframe 
  • Engine Manifold Cover 
  • Turbocharger Cover 
  • Protection Covers for Rotating Parts 
  • Exhaust Insulation Cover 
  • Enclosure DC Light 
  • Operations Manual 
  • 24 Months / 2000 hours Limited Standby Warranty 

Optional Accessories 

  • Main Line CB (3 / 4 Poles – 80% / 100% rated) 
  • Upsize Alternator 
  • Anti-condensation Heater 
  • Voltage Regulation ±0.5% w/MX321 AVR 
  • Gas Regulator 
  • NG / LP Auto Changeover Control System 
  • Low Gas Pressure Alarm 
  • Low Coolant Level Alarm 
  • Oil Pan Heater 
  • Oil Temperature Display on Controller 
  • Manual Speed Adjust Rheostat 
  • Manual Voltage Adjust Rheostat 
  • Remote Annunciator Panel 
  • Remote Control & Monitoring Panel 
  • Advanced SMS Messaging 
  • Control Panel Heater 
  • Battery Disconnect Switch 
  • Battery Heater 
  • Battery Charger 10/20 Amp 
  • Shunt Trip / Aux Contacts 
  • Spring Anti-vibration Isolators 
  • Automatic Transfer Panel (ATS) 
  • 5 Years / 2000 hours Limited Comprehensive Warranty 

Codes & Standards 

  • Designed and manufactured in a facility certified to ISO9001 standards 
  • Designed and manufactured in a facility certified to ISO14001:2015 standards 
  • Single source responsibility for the generator set & accessories 
  • Prototype tested and production tested according to the UL test program 
  • Meets NFPA70, 99, 110, 37 Level 1 when equipped with the necessary accessories and installed per NFPA standards (fast start kit required for NFPA110 Level 1) 

product specifications:

SpecificationValue
Model NameAPD-NG100
Engine MakePSI
Engine Model5.7LT-CAC
Alternator MakeStamford
Control Panel Make & ModelDSE 7320 MK II
Frequency & Speed60Hz, 1800rpm
Enclosure Make & ModelAKSA AUL 41/42
NG Standby Power100 kW
NG Standby Current150A (@480/277V)
LP Gas Standby Power80 kW
LP Gas Standby Current120A (@480/277V)
Rated Power Factor0.8
Engine Displacement & Cylinders5.7L / 8 Cylinders
Engine TypeV-type, 4 Cycle
Engine Speed1800 rpm
Engine Standby Power NG122 kW
Engine Standby Power LP111.16 kW
AspirationForced Induction
Compression Ratio9.4 : 1
Bore / Stroke101.6 mm / 88.4 mm
Governor TypeElectronic
Fuel TypeNG, LP Gas / Dual Fuel
Min NG Supply Pipe Size1-1/4" NPT
Min LPG Supply Pipe Size3/4"
System Voltage (DC)12V
Battery Qty, Rating1 x 60Ah
Radiator Cooling System TypeClosed Circuit
Coolant Capacity, engine only8.1 quart
Cranking Temperature160°F
Full Open Temperature185°F
Combustion Air Required262 cfm
Air Filter TypeDry Paper Element
Oil SpecificationsSAE 5W-30, API Rating SM or Newer
Oil Pan Capacity5.0 Qts
Oil Filter1, Cartridge
Max Allowable Oil Temp250°F
Alternator StandardsBS EN 60034
Alternator Control SystemPMG
Voltage Regulation± 1 %
Insulation SystemClass H
Alternator ProtectionIP23
Controller ManufacturerDSE
Controller Model7320 MK II
Jacket Water HeaterHotstart TPS101GT10-000, 120V, 1000W
Battery ChargerComAp InteliCharger, 85V~264V AC input
Open Skid Dimensions (L x W x H)92 in x 43.3 in x 53.5 in
Open Skid Dry Weight2,700 lbs.
Enclosed Level 1 Dimensions (L x W x H)116 in x 43.3 in x 66 in
Enclosed Level 1 Dry Weight3,900 lbs.
Enclosed Level 1 Sound Pressure @ 7m76 dBA
Enclosed Level 2 Dimensions (L x W x H)116 in x 43.3 in x 82 in
Enclosed Level 2 Dry Weight4,200 lbs.
Enclosed Level 2 Sound Pressure @ 7m72 dBA
CertificationsUL2200, ISO9001, ISO14001:2015, NFPA70/99/110/37 Level 1
Warranty24 Months / 2000 Hours Limited Standby

 

product related documents:

APD-NG100.pdf

Additional Info
Peso4200 lbs
Dimensiones116 × 43.3 × 82 in
Reviews

Valoraciones

No hay valoraciones aún.

Solo los usuarios registrados que hayan comprado este producto pueden hacer una valoración.

Item añadido al carrito View Cart Checkout
Item added to wishlist View Wishlist
Item removed from wishlist