The AKSA Power Generation APD-ULV550 is a UL2200-listed, 550 kW standby diesel generator set built around a Volvo Penta TAD1642GE engine and a Stamford alternator. Designed for emergency and standby power applications, the unit pairs a DSE 7320 MK II control panel with a heavy-duty steel and aluminum enclosure to deliver reliable, code-compliant backup power. Manufactured in facilities certified to ISO9001 and ISO14001:2015, and tested to UL and NFPA110 Level 1 standards, the APD-ULV550 is engineered for demanding commercial and industrial standby power needs. 

Key Features 

  • 550 kW standby power at 480/277V, 0.8 power factor 
  • Volvo Penta TAD1642GE diesel engine, 60Hz / 1800 rpm 
  • Stamford HCI534E alternator with Class H insulation and IP23 protection 
  • DSE 7320 MK II microprocessor-controlled panel, UL & NFPA110 compatible 
  • UL2200 certified for emergency stationary applications 
  • Meets NFPA70, 99, 110, and 37 Level 1 standards 
  • Heavy-duty steel/aluminum enclosure with sound attenuation foam 
  • Engine jacket water heater and battery charger included standard 
  • 24 Months / 2,000 hours limited standby warranty 
  • ISO9001 and ISO14001:2015 certified manufacturing facilities 
Share:
Description
Additional Info
Reviews
Description

 

APD-ULV550 product details and specifications:

General Characteristics 

  • Model Name: APD-ULV550 
  • Engine Make: Volvo 
  • Engine Model: TAD1642GE 
  • Alternator Make: Stamford 
  • Control Panel Make & Model: DSE 7320 MK II 
  • Frequency & Speed: 60Hz, 1800 rpm 
  • Enclosure Make & Model: AKSA AUL 71/72 

Genset Rating (TAD1642GE) 

  • HCI534E (Wnd-311): 480/277V, 550kW standby, 0.8 PF, 827A standby current 
  • HCI534E (Wnd-311): 240/120V, 545kW standby, 0.8 PF, 1639A standby current 
  • HCI534E (Wnd-311): 208/120V, 545kW standby, 0.8 PF, 1891A standby current 
  • HCI534E (Wnd-17): 600/347V, 550kW standby, 0.8 PF, 662A standby current 

Engine Data 

  • Manufacturer: Volvo Penta 
  • Model: TAD1642GE 
  • Displacement & Cylinders: 16.12 L / 6 Cylinders 
  • Engine Speed: 1800 rpm 
  • Engine Standby Power: 585 kW 
  • Engine Prime Power: 532 kW 
  • Aspiration: Turbocharged 
  • Compression Ratio: 16.5 : 1 
  • Bore / Stroke: 144 mm / 165 mm 
  • Effective Mean Pressure, Standby Power: 2.5 Mpa 
  • Max Combustion Pressure, Standby Power: 18.9 Mpa 
  • Total Mass Moment of Inertia: 4.20 kgm² 
  • Friction Power: 53 kW 
  • Wet Weight – Engine Only: 3417 lb 
  • Wet Weight – GenPac: 4453 lb 
  • Engine Crankcase Vent System: Open 

Fuel System 

  • Injection Pump Type: Delphi / E1 
  • System Supply Flow: 53 g/h 
  • System Return Flow: 6.6 g/h 
  • Max Allowable Inlet Fuel Temp: 140 °F 

Fuel Consumption 

  • Standby Power (100%): 38.5 gal/h 
  • Standby Power (75%): 27.8 gal/h 
  • Standby Power (50%): 18.5 gal/h 
  • Standby Power (25%): 10.0 gal/h 

Electric System 

  • Voltage & Type: 24V, Insulated from Earth 
  • Alternator Make / Output: Bosch / 80A 
  • Battery Qty, Rating: 2 x 120Ah 

Cooling System 

  • Radiator Cooling System Type: Closed Circuit 
  • Fan Power Consumption: 19 kW 
  • Coolant Capacity: 15.85 gal 
  • Max Top Tank Temperature: 217 °F 
  • Thermostat, Start – Fully Open: 187–205 °F 

Exhaust System 

  • Exhaust Gas Temp: 954 °C 
  • Max Allowable Back Pressure: 10 kPa 
  • Exhaust Gas Flow: 117.6 m³/min 

Air Intake System 

  • Air Consumption: 46.6 m³/min 
  • Max Intake Air Restriction: 5 kPa 
  • Air Filter Type: Single Stage Paper Cartridge 

Lubrication System 

  • Total System Capacity: 12.7 gal 
  • Sump Capacity Max / Min: 11.1 gal / 8.5 gal 
  • Max Oil Temp: 266 °C 
  • Oil Pressure at Rated Speed: 44–94 psi 
  • Oil Consumption: 0.032 gal/h 

Alternator Data 

  • Manufacturer: Stamford 
  • Standards: BS EN 60034 
  • Control System: PMG 
  • A.V.R.: MX341 
  • Voltage Regulation: ± 1 % 
  • Insulation System: Class H 
  • Protection: IP23 
  • Rated Power Factor: 0.8 
  • Stator Winding: Double Layer Concentric 
  • Winding Pitch: Two Thirds 
  • Winding Leads: 12 
  • Telephone Interference: THF < 2 % 
  • Waveform Distortion: No Load < 1.5 % 
  • Maximum Over speed: 2250 rev/min 

Battery Charger & Electrical System Data 

  • Manufacturer: ComAp 
  • Model: InteliCharger 
  • Input Voltage: 85V ~ 264V AC 
  • Output Voltage / Current: 27.2V Float / 2.5A pk 

Jacket Water Heater Data 

  • Manufacturer: Hotstart 
  • Model: CTM25110-N00 
  • Input Voltage: 120V 
  • Power: 2500W 

Controller Data 

  • Manufacturer: DSE 
  • Model: 7320 MK II 

Controller Features & Benefits 

  • Microprocessor controlled, UL & NFPA110 Compatible 
  • License free PC Software (Non-proprietary Software) 
  • IP65 rating offers increased resistance to water ingress 
  • Modules can be integrated to building management systems 
  • Real time clock provides accurate event log 
  • Four line back-lit LCD text display 
  • Five key menu navigation, two wire start/stop at Auto mode 
  • Front panel editing with PIN protection 
  • Support up to three remote display modules 
  • Configurable timers and alarms 
  • Multiple date and timer scheduler 
  • Integral PLC editor 
  • ‘Protections disabled’ feature 
  • Load switching (load shedding and dummy load outputs) 
  • Fully configurable via DSE Configuration Suite PC Software 
  • SCADA monitoring via DSE Configuration Suite PC Software 

Protection 

  • Gen. Voltage – under / over 
  • Gen. Freq. – under / over 
  • Engine Speed – under / over 
  • Engine Oil Pressure – low 
  • Engine Temp – low / high 
  • Battery Voltage – low / high 
  • Weak Battery 
  • Fail to Start / Stop 
  • Charge Alternator Fail 
  • Over Current & Load (kW/kVAr) 
  • Unbalanced Load 
  • Independent Earth Fault 
  • Reverse Power 
  • Loss of Speed Signal 

Instruments 

  • Gen. Voltage (L-L/L-N) 
  • Gen. Frequency 
  • Engine speed 
  • Oil Pressure 
  • Water Temperature 
  • Battery Voltage 
  • Run Time 
  • Phase Sequence 
  • Power monitoring (kWh/kVAh/kVArh) 
  • Power (kWh/kVAh/kVArh) 
  • Power Factor 
  • Generator Current 
  • Generator Load (%) 
  • Earth Current 

Enclosure Features 

  • Heavy Duty Steel / Aluminum Structure 
  • E-Stop on Enclosure 
  • Control Panel Eliminated from Engine Vibrations 
  • Standard Sound Attenuation Foam 
  • Plastic Covered Corrosion Resistant Locks & Hinges 
  • Internally Mounted Exhaust System with Rain Cap 
  • Coolant Fill Cap 
  • Removable Base Frame Lifting Hooks 
  • Oil & Coolant Drain Ports 
  • Easy Access for Maintenance 

Enclosure & Skid Dimensions 

  • Open Skid Gen: Length 157.5 in, Width w/o lift hooks 74.8 in, Height 75.8 in, Dry Weight 9085 lb 
  • Level 1 Enclosure: Length 205 in, Width w/o lift hooks 77 in, Height 89.9 in, Dry Weight 14030 lb, Sound Pressure @ 7m 79 dB(A) 
  • Level 2 Enclosure: Length 224.6 in, Width w/o lift hooks 77 in, Height 89.9 in, Dry Weight 14405 lb, Sound Pressure @ 7m 77 dB(A) 

Fuel Tank – UL142 Listed Base Design 

  • 24hr (1000gal): Dimensions 225/74.8/22 in, Weight 3400 lb 
  • 48hr (1780gal): Dimensions 225/74.8/35 in, Weight 4350 lb 
  • 72hr (3000gal): Dimensions 350/74.8/36 in, Weight 6200 lb 

Standard Features & Accessories 

  • UL2200 Certification 
  • Heavy Duty Steel Base Frame 
  • PMG w/MX341 AVR 
  • Engine Jacket Water Heater 
  • Battery and Battery Rack 
  • Battery Charger 
  • Anti Vibration Pads between Engine/Alternator & Base Frame 
  • Critical Grade Silencer Inside Enclosure 
  • Residential Grade Silencer Set for Open Skid Sets 
  • Exhaust outlet rain cap and radiator fill cap 
  • Sound Absorb Foam Material for Enclosure 
  • Emergency Stop Button 
  • Oil Drain Valve 
  • Coolant Drain Valve 
  • Jacket Water Heater Isolation Valves 
  • Flex Fuel Lines 
  • Air Filter Restriction Gauge 
  • Engine Manifold Cover 
  • Turbocharger Cover 
  • Protection Covers for Rotating Parts 
  • Exhaust Insulation Cover 
  • Enclosure DC Light 
  • Operations Manual 
  • 24 Months / 2000 hours Limited Standby Warranty 

Optional Accessories 

  • Main Line CB (3/4 Poles – 80%/100% rated) 
  • Upsize Alternator 
  • Voltage Regulation ±0.5% w/MX321 AVR 
  • Anti-condensation Heater 
  • Sub Base Fuel Tank (UL142 / UL2085) 
  • Fuel Level Display & Alarm on Controller 
  • Low / High Fuel Alarms 
  • Fuel Water Separator Filter 
  • Auto Fuel Fill Control System 
  • Oil Temperature Display on Controller 
  • Manual Speed Adjust Rheostat 
  • Manual Voltage Adjust Rheostat 
  • Remote Annunciator Panel 
  • Remote Control & Monitoring Panel 
  • Advanced SMS Messaging 
  • Control Panel Heater 
  • Battery Disconnect Switch 
  • Battery Heater 
  • Battery Charger 10/20 Amp 
  • Shunt Trip / Aux Contacts 
  • Spring Anti-vibration Isolators 
  • Automatic Transfer Panel (ATS) 
  • 5 Years / 2000 hours Limited Comprehensive Warranty 

Codes & Standards 

  • Designed and manufactured in a facility certified to ISO9001 standards 
  • Designed and manufactured in a facility certified to ISO14001:2015 standards 
  • AKSA Power Generation provides single source responsibility for the generator set & accessories 
  • Prototype tested and production tested according to the UL test program 
  • Meets NFPA70, 99, 110, 37 Level 1 when equipped with necessary accessories and installed per NFPA standards 
  • EPA – Certified for Emergency Stationary Applications 

product specifications:

SpecificationValue
Model NameAPD-ULV550
Engine MakeVolvo
Engine ModelTAD1642GE
Alternator MakeStamford
Control Panel Make & ModelDSE 7320 MK II
Frequency & Speed60Hz, 1800 rpm
Enclosure Make & ModelAKSA AUL 71/72
Standby Power Rating550 kW
Standby Voltage480/277V
Power Factor0.8
Standby Current827A
Engine ManufacturerVolvo Penta
Displacement & Cylinders16.12 L / 6 Cylinders
Engine Speed1800 rpm
Engine Standby Power585 kW
Engine Prime Power532 kW
AspirationTurbocharged
Compression Ratio16.5 : 1
Bore / Stroke144 mm / 165 mm
Effective Mean Pressure, Standby Power2.5 Mpa
Max Combustion Pressure, Standby Power18.9 Mpa
Total Mass Moment of Inertia4.20 kgm2
Friction Power53 kW
Wet Weight - Engine Only3417 lb
Wet Weight - GenPac4453 lb
Engine Crankcase Vent SystemOpen
Injection Pump TypeDelphi / E1
System Supply Flow53 g/h
System Return Flow6.6 g/h
Max Allowable Inlet Fuel Temp140 F
Fuel Consumption - Standby Power (100%)38.5 gal/h
Fuel Consumption - Standby Power (75%)27.8 gal/h
Fuel Consumption - Standby Power (50%)18.5 gal/h
Fuel Consumption - Standby Power (25%)10.0 gal/h
Electric System Voltage & Type24V, Insulated from Earth
Charging Alternator Make / OutputBosch / 80A
Battery Qty, Rating2 x 120Ah
Radiator Cooling System TypeClosed Circuit
Fan Power Consumption19 kW
Coolant Capacity15.85 gal
Max Top Tank Temperature217 F
Thermostat, Start - Fully Open187-205 F
Exhaust Gas Temp954 C
Max Allowable Back Pressure10 kPa
Exhaust Gas Flow117.6 m3/min
Air Consumption46.6 m3/min
Max Intake Air Restriction5 kPa
Air Filter TypeSingle Stage Paper Cartridge
Total Lubrication System Capacity12.7 gal
Sump Capacity Max / Min11.1 gal / 8.5 gal
Max Oil Temp266 C
Oil Pressure at Rated Speed44-94 psi
Oil Consumption0.032 gal/h
Alternator StandardsBS EN 60034
Alternator Control SystemPMG
A.V.R.MX341
Voltage Regulation+/- 1%
Insulation SystemClass H
Alternator ProtectionIP23
Rated Power Factor0.8
Stator WindingDouble Layer Concentric
Winding PitchTwo Thirds
Winding Leads12
Telephone InterferenceTHF < 2%
Waveform DistortionNo Load < 1.5%
Maximum Over Speed2250 rev/min
Battery Charger ManufacturerComAp
Battery Charger ModelInteliCharger
Battery Charger Input Voltage85V ~ 264V AC
Battery Charger Output Voltage / Current27.2V Float / 2.5A pk
Jacket Water Heater ManufacturerHotstart
Jacket Water Heater ModelCTM25110-N00
Jacket Water Heater Input Voltage120V
Jacket Water Heater Power2500W
Controller ManufacturerDSE
Controller Model7320 MK II
Open Skid Length157.5 in
Open Skid Width w/o lift hooks74.8 in
Open Skid Height75.8 in
Open Skid Dry Weight9085 lb
Level 1 Enclosure Length205 in
Level 1 Enclosure Width w/o lift hooks77 in
Level 1 Enclosure Height89.9 in
Level 1 Enclosure Dry Weight14030 lb
Level 1 Sound Pressure @ 7 meters79 dB(A)
Level 2 Enclosure Length224.6 in
Level 2 Enclosure Width w/o lift hooks77 in
Level 2 Enclosure Height89.9 in
Level 2 Enclosure Dry Weight14405 lb
Level 2 Sound Pressure @ 7 meters77 dB(A)
Fuel Tank 24hr (1000gal) Dimensions (L/W/H)225 / 74.8 / 22 in
Fuel Tank 24hr (1000gal) Weight3400 lb
Fuel Tank 48hr (1780gal) Dimensions (L/W/H)225 / 74.8 / 35 in
Fuel Tank 48hr (1780gal) Weight4350 lb
Fuel Tank 72hr (3000gal) Dimensions (L/W/H)350 / 74.8 / 36 in
Fuel Tank 72hr (3000gal) Weight6200 lb

 

product related documents:

APD-ULV550.pdf

Additional Info
Weight14405 lbs
Dimensions224.6 × 77 × 89.9 in
Reviews

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Item added to cart View Cart Checkout
Item added to wishlist View Wishlist
Item removed from wishlist