McPherson Controls | 400A 3Pole Automatic Transfer Switch | ATS22/400/3N3 multi-Voltage
McPherson Controls | 400A 3Pole Automatic Transfer Switch | ATS22/400/3N3 multi-Voltage
$2,929.00
ATS-22 Controller, BTS2BE0400 Transfer Switch: reliable motor-operated transfer mechanism with mechanical interlock.
Automatic Transfer Switch, 400 AMPS, 3 Pole / 1 Phase, 50 Hz or 60 Hz, Multi-Voltage: 208-480V adjustable, Automatic with Emergency Manual override, NEMA 3R Weather-Proof Enclosure for Indoor or Outdoor use.
Generator Exerciser settings: off, day, hour & minute: once a week, once every 2 weeks, once every 3 weeks, once every 4 weeks, without load or with load.
Pictures shown are representative and may not reflect exact model or other specifications.
Usually ships in 3-5 business days if in stock at the factory when placing the order.
McPherson Controls ATS22/400/3N3
multi-Voltage
Details and Specifications
- Micro-processor based & full glass panel design.
- Smart m-Touch touch sensing design.
- Compact size with user-friendly LED display.
- Capacitive touch key programming & operation.
- All operation can be done directly on touch panel or from PC connection.
- Program settings are Auto-saved into memory and will remain saved even when power is disconnected.
- Provides full phase voltage & frequency monitoring & protection for both normal & standby source.
- Transfer fail alarm, Pre-exerciser or Pre-transfer signal output.
- Optional USB / RS485 / Ethernet remote communication functions.
- Free APP for monitor and operate your ATS & genset directly from your smart phone (when equipped with Ethernet communication module).
- Built-in 1 to 4 weeks exerciser timer.
- Built-in noise filter and protect fuses for both normal & standby source.
Product Specifications:
Specifications | |
Rated Voltage | 100 - 600 VAC |
Rated Current (Ambient Temp. 40°C) | 400 Amp |
Rated Frequency | 50/60 Hz |
Switch Type | Molded Case Circuit Breaker (MCCB) |
Poles | 3 Poles |
Remote Start Output Relay Contact | 7A @ 250 Vac Max. |
Normal ON Relay Contact | 7A @ 250 Vac Max. |
Emergency ON Relay Contact | 7A @ 250 Vac Max. |
Alarm Auxiliary Output Relay Contact | 7A @ 250 Vac Max. |
Rated Breaking Capacity IEC 60947-2 Icu / Ics (KA) | |
240V | 35 |
380V | 25 |
415V | 25 |
440V | 18 |
500V | 15 |
Adjustable Timer Settings: | |
TDNE Time Delay Normal to Emergency | 0 to 250 seconds |
TDES Time Delay Engine Start | 0 to 30 seconds |
TDEN Time Delay Emergency to Normal | 0 to 999 seconds |
TDEC Time Delay Engine Cool-down | 0 to 250 seconds |
TDOF Time Delay in OFF position | 0 to 99 seconds |
PRODUCT Related documents:
ATS-22 complete Manual -for all purpose
Weight | 150 lbs |
---|---|
Dimensions | 14 × 24 × 40 in |