C80D6 Diesel (80kW) 120/240 1Ph – 24hr Fuel Tank



C80D6 Diesel (80kW) 120/240 1Ph – 24hr Fuel Tank
Call for Price
The Cummins C80D6 is an 80 kW / 80 kVA preconfigured standby diesel generator set built around a rugged, 4-cycle Cummins QSB5 industrial diesel engine. Paired with a PowerCommand 1.1 electronic control and a 24-hour sub-base fuel tank, it delivers dependable 120/240V single-phase backup power for demanding applications. The unit is housed in a Level 1 sound-attenuated aluminum enclosure rated to withstand 180 mph wind loads, and is built to perform reliably across an extreme ambient temperature range.
Key Features
- 80 kW / 80 kVA standby power output at 120/240V, single-phase, 60 Hz
- Cummins QSB5 4.5L 4-cycle industrial diesel engine rated at 1800 rpm
- PowerCommand 1.1 electronic control with automatic remote start/stop, precise voltage and frequency regulation, and auto-shutdown fault detection
- 24-hour dual-wall sub-base fuel tank (260 gallon usable volume)
- Level 1 sound-attenuated aluminum enclosure with durable powder-coat finish
- Enclosure evaluated to withstand 180 mph wind loads per ASCE 7-10
- Standard coolant heater for reliable cold-weather starting
- Wide operating temperature range: -40°F to +122°F (-40°C to +50°C)
- Brushless, 4-pole alternator with Class H insulation and low waveform distortion
- Meets NFPA 110 Level 1 prototype test requirements (PTS); certified to U.S. EPA and UL 2200 standards
- Adjustable 400 Amp circuit breaker
- Standard 6A battery charger
C80D6 - Details & Specifications:
General
- Model: C80D6
- Model Number: A063P967
- Standby Rating: 80 kW / 80 kVA (60 Hz)
- Fuel Tank: 24 Hr. sub-base tank (260 gal usable volume)
- Voltage - Phase: 120/240V, 1 Phase
Engine Specifications
- Engine: Cummins QSB5
- Displacement: 4.5 L (272 in³)
- Cylinder Block: Cast iron, in-line
- Rated Speed: 1800 rpm
- Battery Capacity (at 0°C/32°F): 2 x 850 amps
- Battery Charging Alternator: 100 amps
- Starting Voltage: 2 x 12-volt, negative ground
- Lube Oil Filter Type: Spin-on with relief valve
- Fuel Consumption - 50% Load: 4.00 gph
- Fuel Consumption - 100% Load: 7.30 gph
Alternator Specifications
- Design: Brushless, 4-pole, drip-proof, revolving field
- Stator: 2/3 pitch
- Rotor: Direct coupled, flexible disc
- Insulation System: Class H per NEMA MG1-1.65
- Standard Temp. Rise: 120°C (248°F) Standby
- Exciter Type: Torque match (shunt), with PMG as option
- Alternator Cooling: Direct drive centrifugal blower
- AC Waveform (THDV): < 5% no load to full linear load, < 3% for any single harmonic
- Telephone Influence Factor (TIF): < 50 per NEMA MG1-22.43
- Telephone Harmonic Factor (THF): < 3%
Control System
- Controller: PowerCommand 1.1 electronic control
- Automatic remote starting/stopping
- Precise frequency and voltage regulation
- Alarm and status message display
- Output metering with auto-shutdown at fault detection
- Governor Regulation Class: ISO 8528 Part 1 Class G3
- Voltage Regulation (no load to full load): ± 1.0%
- Random Voltage Variation: ± 1.0%
- Frequency Regulation: Isochronous
- Random Frequency Variation: ± 0.5%
Electrical
- Circuit Breaker: 400 Amps (adjustable)
- Battery Charger: Standard - 6A
- Radio Frequency Emissions Compliance: FCC Title 47 Part 15, Class A and B
Enclosure
- Type: Sound Level 1, Sandstone
- Material: Aluminum with durable powder-coat paint finish
- Sound Level: 74.6 dB(A) at 23 ft (7 m), full rated load
- Wind Load Rating: 180 mph per ASCE 7-10
Operating Environment
- Operating Temp. Range: -40°F to +122°F (-40°C to +50°C)
- Coolant heaters standard for cold-weather starting
Dimensions & Weight (with 24-hr fuel tank)
- Length: 119 in.
- Width: 40 in.
- Height: 83 in.
- Dry Weight: 3,309 lbs.
- Wet Weight: 3,425 lbs.
Certifications & Codes
- Designed and manufactured in facilities certified to ISO 9001 / ISO 9002
- UL 2200 Listed - Stationary Engine Generator Assemblies
- Meets Prototype Test Support (PTS) requirements of NFPA 110 for Level 1 systems
- Engine certified to U.S. EPA SI Stationary Emission Regulation, 40 CFR Part 60
Warranty
- 2-year base warranty when used in EPA-Stationary Emergency application
- Extended warranty options available through Cummins dealers
product specifications:
| Specification | Value |
| Model | C80D6 |
| Model Number | A063P967 |
| Fuel Tank | 24 Hr. (260 gal usable volume) |
| Standby Rating (60 Hz) | 80 kW / 80 kVA |
| Engine | Cummins QSB5, 4.5L (272 in³) |
| Rated Speed | 1800 rpm |
| Cylinder Block | Cast iron, in-line |
| Controller | PowerCommand 1.1 |
| Voltage - Phase | 120/240V, 1 Phase |
| Operating Temp. Range | -40°F to +122°F (-40°C to +50°C) |
| Circuit Breaker | 400 Amps (adjustable) |
| Battery Charger | Standard - 6A |
| Governor Regulation Class | ISO 8528 Part 1 Class G3 |
| Voltage Regulation (no load to full load) | ± 1.0% |
| Random Voltage Variation | ± 1.0% |
| Frequency Regulation | Isochronous |
| Random Frequency Variation | ± 0.5% |
| Radio Frequency Emissions Compliance | FCC Title 47 Part 15, Class A and B |
| Sound Level | 74.6 dB(A) at 23 ft (7 m), full rated load |
| Fuel Consumption - 50% Load | 4.00 gph |
| Fuel Consumption - 100% Load | 7.30 gph |
| Battery Capacity (at 0°C/32°F) | 2 x 850 amps |
| Battery Charging Alternator | 100 amps |
| Starting Voltage | 2 x 12-volt, negative ground |
| Lube Oil Filter Type | Spin-on with relief valve |
| Alternator Design | Brushless, 4-pole, drip-proof, revolving field |
| Alternator Stator | 2/3 pitch |
| Alternator Rotor | Direct coupled, flexible disc |
| Insulation System | Class H per NEMA MG1-1.65 |
| Standard Temp. Rise | 120°C (248°F) Standby |
| Exciter Type | Torque match (shunt); PMG optional |
| Alternator Cooling | Direct drive centrifugal blower |
| AC Waveform (THDV) | < 5% no load to full linear load, < 3% any single harmonic |
| Telephone Influence Factor (TIF) | < 50 per NEMA MG1-22.43 |
| Telephone Harmonic Factor (THF) | < 3% |
| Enclosure | Sound Level 1, Sandstone, Aluminum with powder-coat paint |
| Wind Load Rating | 180 mph per ASCE 7-10 |
| Certifications | ISO 9001; UL 2200 Listed; NFPA 110 Level 1 (PTS); U.S. EPA SI Stationary Emission Regulation 40 CFR Part 60 |
| Warranty | 2-year base warranty (EPA-Stationary Emergency application) |
| Dry Weight | 3,309 lbs. |
| Wet Weight | 3,425 lbs. |
| Dimensions (L x W x H) | 119 in. x 40 in. x 83 in. |
product related documents:
| Weight | 3309 lbs |
|---|---|
| Dimensions | 119 × 40 × 83 in |
Only logged in customers who have purchased this product may leave a review.





Reviews
There are no reviews yet.