Blue Star JD300-02 3PH (300kWe)

Share this product!

Blue Star JD300-02 3PH (300kWe)

SKU: JD300-02

The Blue Star Power Systems JD300-02 is a 300 kWe diesel-powered emergency stationary standby generator set built on a John Deere 6090HFG86 engine. Operating at 480/277V three-phase, 60 Hz at 1800 RPM, it is UL 2200 listed, CSA approved, and EPA Tier 3 certified. Designed for demanding commercial and industrial applications, it features a Level 2 weather-proof powder-coated steel enclosure rated for 200 MPH wind loads, a Stamford brushless alternator, and a Blue Star DCP7310 digital control panel. 

Key Features 

  • 300 kWe standby power rating at 1800 RPM, 60 Hz 
  • John Deere 6090HFG86 engine — 6-cylinder inline, 4-cycle, turbocharged with CAC, 463 HP standby 
  • Stamford S4L1D-D41 brushless single-bearing alternator with MX321 automatic voltage regulator and PMG excitation 
  • Blue Star DCP7310 microprocessor-based digital control panel with NFPA 110 Level 1 compatibility 
  • Level 2 weather-proof enclosure with 1.5″ Type D acoustical foam, powder-coated 14-gauge steel, 200 MPH wind rated 
  • 480/277V three-phase, 60 Hz operation at 0.8 power factor 
  • UL 2200 & cUL listed, CSA certified, EPA Tier 3 certified, seismic certified to IBC 2021 
  • NFPA 110 / CSA C282 compliant 
  • Unit-mounted radiator for 50°C ambient cooling 
  • 450-amp, 3-pole, 600V mainline circuit breaker mounted and wired in a NEMA 1 enclosure 
  • Engine block jacket water heater: 2500W, 240VAC, rated for -20°F 
  • Critical grade CPJ Series silencer mounted to engine 
  • 72-hour / 1,620-gallon UL 142 listed double-wall sub-base fuel tank with secondary containment 
  • 12V battery system with 6-amp battery charger 
  • Dry single-stage air cleaner 
  • Vibration isolation mounts and formed steel base 
  • 2-year / 2,000-hour standby limited warranty 
  • Standard factory load test included 
This product require a prior technical study of your needs in order to offer you a price. Please click on "Request a quote".
 
Share:
Description
Additional Info
Reviews
Description

 

JD300-02 product details and specifications:

Project Overview 

  • Unit Model: JD300-02 
  • Standby / Prime: Emergency Stationary Standby 
  • kWe Rating: 300 kWe 
  • Fuel: Diesel 
  • UL 2200 Listed: Yes 
  • CSA Approved: Yes 
  • EPA: Tier 3 
  • Paint Color: White 

Engine 

  • Manufacturer: John Deere 
  • Engine Model: 6090HFG86 
  • Type: 4-Cycle 
  • Aspiration: Turbo Charged, CAC 
  • Cylinder Arrangement: 6 Cylinder Inline 
  • Displacement: 549 Cu. In. (9.00 lit) 
  • Bore x Stroke: 4.70 in. (11.8 cm) x 5.40 in. (13.6 cm) 
  • Compression Ratio: 16.0:1 
  • Rated RPM: 1800 
  • Max HP Standby: 463 HP (345 kWm) 
  • Governor: Electronic Isochronous 

Electrical Ratings — 480/277V Three Phase 

  • Voltage: 480/277V 
  • Phase: 3 Phase 
  • Frequency: 60 Hz 
  • Power Factor: 0.8 
  • kWe: 300 
  • Amperage: 452 Amps 
  • Temperature Rise: 125°C Standby / 40°C Ambient 

Alternator 

  • Generator Model: Stamford S4L1D-D41 
  • Connection: 12 Lead Wye 
  • Type: Brushless Single Bearing 
  • Automatic Voltage Regulator: Stamford MX321 with PMG Excitation 
  • Voltage Regulation: ±0.050% 
  • Poles: 4 Pole, Rotating Field 
  • Temperature Rise: 125°C Standby 
  • One Step Load Acceptance: 100% of Rated Load 
  • Maximum Harmonic Content: 5% 
  • Standards: NEMA MG 1, IEEE and ANSI Compliance for Temperature Rise 

Control Panel 

  • Panel: Blue Star DCP7310 Microprocessor Based Gen-Set Controller 
  • Location: Mounted Facing Left from Generator End (Unless Specified Otherwise) 
  • Enclosure: NEMA 12 
  • Standard Shutdowns: Low Oil Pressure, High Coolant Temp, Overspeed, Overcrank 
  • Alarms: Emergency Stop Pushbutton, Audible Alarm Buzzer with Silencing Switch 
  • Digital Metering, Engine Parameters, Generator Protection Functions 
  • CAN Bus (J1939) ECU Communications 
  • RS485 Communicator Interface, Windows-Based Software, Multilingual Capability 
  • 8 Programmable Contact Inputs / 10 Contact Outputs 
  • IP65 Rating (with supplied gasket) — increased water ingress resistance 
  • NFPA 110 Level 1 Compatible 
  • cULus Listed, CE Approved 

Enclosure 

  • Level: Level 2 — Weather Proof with Foam 
  • Material: Powder Coated 14 Gauge Steel 
  • Wind Rating: Rugged and Durable, 200 MPH Wind Rated 
  • Roof: Pitched Roof for Increased Structural Integrity and Improved Watershed 
  • Openings: Punched Intake with Baffle and Punched Exhaust Openings 
  • Doors: Keyed Alike Lockable with Draw Down Latches and Stainless Steel Component Hinges 
  • Sound Attenuation: Additional 1.5" Thick Polydamp Type D Acoustical Foam (PAF) 
  • Base: Formed Steel with Mounting and Lifting Holes 
  • Vibration Mounts: Included to Isolate Unit from Base Rail 

Cooling System 

  • Type: Unit Mounted Radiator 
  • Ambient Capacity: 122°F (50°C) 
  • Water Pump Flow Rate: 78.0 GPM (295 lit/min) 
  • Heat Rejection to Coolant: 6,489 BTUM (114 kW) 
  • Heat Rejection to CAC: 5,641 BTUM (99.1 kW) 
  • Heat Radiated to Ambient: 5,997 BTUM (105 kW) 
  • System Coolant Capacity: 13.2 gal (50.0 lit) 
  • Engine Jacket Water Capacity: 4.23 gal (16.0 lit) 

Exhaust System 

  • Silencer: Critical Grade Compact CPJ Series — Mounted to Engine 
  • Gas Temperature at Stack: 927°F (497°C) 
  • Gas Volume at Stack Temp: 2,246 CFM (63.6 m3/min) 
  • Maximum Allowable Exhaust Restriction: 30.0 in. H2O (7.50 kPa) 

Fuel System 

  • Fuel Type: Diesel 
  • Fuel Connector: Flexible Fuel Connector 
  • Fuel Consumption at 100% Load: 21.2 gal/hr (80.3 lit/hr) 
  • Fuel Consumption at 75% Load: 17.2 gal/hr (65.2 lit/hr) 
  • Fuel Consumption at 50% Load: 12.9 gal/hr (48.8 lit/hr) 

Fuel Tank 

  • Type: UL 142 Listed Sub-Base Fuel Tank 
  • Construction: Double Wall with Secondary Containment 
  • Options: 24 Hr / 540 Gal | 48 Hr / 1,080 Gal | 72 Hr / 1,620 Gal 
  • Stub-up Area: 8 x 8 Electrical Stub-Up Area Included 
  • Features: Supply & Return Connections, Fuel Level Gauge, Fuel Leak Switch, Fill & Vent Plumbing 

Circuit Breaker 

  • Rating: 450 Amp, 3 Pole, 600 Volt 
  • Enclosure: Mounted and Wired in a NEMA 1 Enclosure 

Battery System 

  • Battery: 12 Volt System with Rack and Cables 
  • Charger: BC1206A Series — 12 Volt, 6 Amp, Mounted and Wired to Terminal 

Air System 

  • Air Cleaner: Dry Single Stage 
  • Aspirating: 936 CFM (26.5 m3/min) 
  • Air Flow Required for Radiator Cooled Unit: 19,014 CFM (538 m3/min) 

Fluid Capacities 

  • Total Oil System: 8.20 gal (31.0 lit) 
  • Engine Jacket Water Capacity: 4.23 gal (16.0 lit) 
  • System Coolant Capacity: 13.2 gal (50.0 lit) 

Mounting & Additional 

  • Base: Formed Steel 
  • Oil Drain Extension: Plumbed to Bulkhead Fitting in Base 
  • Jacket Water Heater: 2500W, 240VAC, rated for -20°F, with Isolation Valves, Wired to Terminal 
  • Vibration Isolation Mounts: Included 

Certifications & Standards 

  • UL 2200 & cUL Listed 
  • CSA Certified 
  • EPA Tier 3 Certified 
  • Seismic Certified to IBC 2021 
  • NFPA 110 / CSA C282 Compliant 

Weights & Dimensions 

  • OPU: 120 x 66 x 82 in — 5,800 lbs. 
  • Level 1 Enclosure: 156 x 66 x 94 in — 7,050 lbs. 
  • Level 2 Enclosure: 156 x 66 x 94 in — 7,225 lbs. 
  • Level 3 Enclosure: 196 x 66 x 94 in — 7,375 lbs. 
  • 24 Hr Tank (540 gal): 120 x 66 x 118 in 
  • 48 Hr Tank (1,080 gal): 162 x 66 x 130 in 
  • 72 Hr Tank (1,620 gal): 228 x 66 x 130 in 

Sound Data (at 23 ft / 7 m per ISO 8528-10) 

  • OPU: 85 dBA No Load / 87 dBA Full Load 
  • Level 1 Enclosure: 81 dBA No Load / 83 dBA Full Load 
  • Level 2 Enclosure: 76 dBA No Load / 78 dBA Full Load 
  • Level 3 Enclosure: 69 dBA No Load / 71 dBA Full Load 

Factory Test & Warranty 

  • Factory Test: Standard Commercial Testing — Verification of Alarm Shutdowns, Voltage Settings, Block Loading to Rated kWe and PF 
  • Warranty: 2 Year / 2000 Hour Standby Limited 

product specifications:

SpecificationValue
MODEL
ModelJD300-02
Power Rating300 kWe
ApplicationEmergency Stationary Standby
ENGINE
Engine ManufacturerJohn Deere
Engine Model6090HFG86
Engine Type4-Cycle
AspirationTurbo Charged, CAC
Cylinder Arrangement6 Cylinder Inline
Displacement549 Cu. In. (9.00 lit)
Bore x Stroke4.70 in. x 5.40 in.
Compression Ratio16.0:1
Rated RPM1800 RPM
Max HP Standby463 HP (345 kWm)
GovernorElectronic Isochronous
ELECTRICAL
Voltage480/277V Three Phase
Frequency60 Hz
Power Factor0.8
Phase3 Phase
Amperage (480V)452 Amps
ALTERNATOR
Generator ModelStamford S4L1D-D41
Connection12 Lead Wye
BearingSingle Bearing, Brushless
Voltage RegulatorStamford MX321 AVR with PMG Excitation
Voltage Regulation+/- 0.5%
Temperature Rise125 deg C Standby / 40 deg C Ambient
Poles4 Pole, Rotating Field
Harmonic Content5% Maximum
StandardsNEMA MG 1, IEEE and ANSI
CONTROL PANEL
Panel ModelBlue Star DCP7310
Panel TypeMicroprocessor Based Digital
Panel EnclosureNEMA 12
Panel LocationMounted Facing Left from Generator End
Standard ShutdownsLow Oil Pressure, High Coolant Temp, Overspeed, Overcrank
AlarmsEmergency Stop Pushbutton, Audible Alarm with Silencing Switch
Standards ComplianceNFPA 110 Level 1 Compatible
ENCLOSURE
Enclosure LevelLevel 2 - Weather Proof with Foam
Enclosure MaterialPowder Coated 14 Gauge Steel
Wind Rating200 MPH
Sound Attenuation1.5" Polydamp Type D Acoustical Foam (PAF)
RoofPitched Roof
DoorsKeyed Alike Lockable with Draw Down Latches, SS Hinges
Paint ColorWhite
COOLING SYSTEM
Cooling TypeUnit Mounted Radiator
Radiator Ambient Capacity122 deg F (50 deg C)
Water Pump Flow Rate78.0 GPM (295 lit/min)
System Coolant Capacity13.2 gal (50.0 lit)
EXHAUST SYSTEM
Silencer TypeCritical Grade Compact CPJ Series
Gas Temp at Stack927 deg F (497 deg C)
Max Exhaust Restriction30.0 in. H2O
FUEL SYSTEM
Fuel TypeDiesel
Fuel ConnectorFlexible
Fuel Consumption at 100%21.2 gal/hr
Fuel Consumption at 75%17.2 gal/hr
Fuel Consumption at 50%12.9 gal/hr
FUEL TANK
Tank TypeUL 142 Listed Sub-Base Double Wall
Tank Capacity Options540 gal (24 hr), 1,080 gal (48 hr), 1,620 gal (72 hr)
Tank FeaturesSecondary Containment, Fuel Level Gauge, Fuel Leak Switch
CIRCUIT BREAKER
Mainline Breaker450 Amp, 3 Pole, 600 Volt
Breaker EnclosureNEMA 1
BATTERY SYSTEM
Battery Voltage12 Volt
Battery Charger12V 6 Amp BC1206A Series
Battery SystemRack and Cables Included
FLUID CAPACITIES
Total Oil System8.20 gal (31.0 lit)
Engine Jacket Water Capacity4.23 gal (16.0 lit)
AIR SYSTEM
Air CleanerDry Single Stage
Aspirating CFM936 CFM (26.5 m3/min)
Air Flow for Radiator19,014 CFM (538 m3/min)
MOUNTING
BaseFormed Steel
Vibration IsolationVibration Isolation Mounts Included
Oil Drain ExtensionPlumbed to Bulkhead Fitting in Base
Jacket Water Heater2500W, 240VAC, rated for -20 deg F
CERTIFICATIONS & STANDARDS
UL ListingUL 2200 & cUL Listed
CSACSA Certified
EPATier 3 Certified
SeismicSeismic Certified to IBC 2021
NFPANFPA 110 / CSA C282 Compliant
WARRANTY & TESTING
Warranty2 Year / 2000 Hour Standby Limited
Factory TestStandard Commercial Load Test Included

 

product related documents:

2026 EPA Cert 450hab-tjdxl09-0114-009 JD250-02, JD275-02, JD300-02.pdf

JD300-02 Engine Data Sheet 12-5-23.pdf

JD300-02_SpecSheet.pdf

JD300-02.pdf

JD300-02_Drawings.pdf

Additional Info
Weight7225 lbs
Dimensions156 × 66 × 94 in
Reviews

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Item added to cart View Cart Checkout
Item added to wishlist View Wishlist
Item removed from wishlist