Aksa Gas Generator APD-NG40 (40kW)



Aksa Gas Generator APD-NG40 (40kW)
Call for Price
The AKSA Power Generation APD-NG40 is a 40 kW dual-fuel standby generator set built around a PSI 4.3L, 6-cylinder engine paired with a Stamford UCI224D alternator. Designed for reliable emergency backup power, the unit runs on natural gas or LP gas and is controlled by a DSE 7320 microprocessor-based control panel. Backed by UL2200 listing and built to meet NFPA 70, 99, 110, and 37 standards, the APD-NG40 is engineered for dependable performance in commercial, industrial, and residential standby applications, and is available on an open skid or in sound-attenuated enclosures.
Key Features
- 40 kW standby power output on both natural gas and LP gas
- PSI 4.3L, 6-cylinder, naturally aspirated engine with electronic governor
- Stamford UCI224D brushless alternator, Class H insulation, ±1% voltage regulation
- DSE 7320 MK II microprocessor controller with UL & NFPA 110 compatibility
- UL2200 certified; meets NFPA 70, 99, 110 (Level 1), and 37 standards
- Engine jacket water heater, battery charger, and battery/rack included standard
- Heavy-duty steel base frame with anti-vibration pads and critical-grade silencer
- Available as open skid or in sound-attenuated enclosures (Level 1 or Level 2)
- 24 months / 2,000 hours limited standby warranty
APD-NG40 product details and specifications:
General Characteristics
- Model Name: APD-NG40
- Engine Make: PSI
- Engine Model: 4.3L
- Alternator Make: Stamford
- Control Panel Make & Model: DSE 7320 MK II
- Frequency & Speed: 60Hz, 1800rpm
- Enclosure Make & Model: AKSA AUL 31/32
Genset Rating
- PSI 4.3L / UCI224D (Wnd-311): 480/277V, PF 0.8 — NG 40kW/60A, LP 40kW/60A
- PSI 4.3L / UCI224D (Wnd-311): 240/120V 1ph, PF 1 — NG 37kW/155A, LP 40kW/166A
- PSI 4.3L / UCI224D (Wnd-311): 208/120V, PF 0.8 — NG 40kW/138A, LP 40kW/138A
- PSI 4.3L / PI144J (Wnd-17): 600/347V, PF 0.8 — NG 40kW/48A, LP 40kW/48A
- PSI 4.3L / UCI224D (Wnd-311): 240/120V, PF 0.8 — NG 40kW/120.3A, LP 40kW/120.3A
- EPA Certified for Emergency Stationary Applications
Engine Data
- Manufacturer: PSI
- Model: 4.3L
- Displacement & Cylinders: 4.3L / 6 Cylinders
- Engine Type: V-type, 4 Cycle
- Engine Speed: 1800rpm
- Engine Standby Power NG: 58.18 kW
- Engine Standby Power LP: 61.27 kW
- Aspiration: Naturally Aspired
- Compression Ratio: 9.4 : 1
- Bore / Stroke: 101.6 mm / 88 mm
- Governor Type: Electronic
Fuel System
- Fuel Type: NG, LP Gas / Dual Fuel
- Min NG Supply Pipe Size: 1-1/4” NPTF
- Min LPG Supply Pipe Size: ¾”
- Maximum EPR Rated Pressure: 6.9 kPa / 1.0 psi
- Max Pressure to EPR: 2.7 kPA / 11.0 inH2O
- Min Pressure to EPR: 1.7 kPA / 7.0 inH2O
Fuel Consumption
- Standby Power 100%: NG 600 cfh (17.0 m3/hr) / LP 245 cfh (6.9 m3/hr)
- Standby Power 75%: NG 500 cfh (14.1 m3/hr) / LP 200 cfh (5.7 m3/hr)
- Standby Power 50%: NG 380 cfh (10.7 m3/hr) / LP 150 cfh (4.2 m3/hr)
- Standby Power 25%: NG 250 cfh (7.1 m3/hr) / LP 100 cfh (2.9 m3/hr)
Electric System
- System Voltage (DC): 12V
- Battery Qty, Rating: 1 x 54Ah
Cooling System
- Radiator Cooling System Type: Closed Circuit
- Coolant Capacity, Engine Only: 7.75 quart
- Cranking Temperature: 160˚F
- Full Open Temperature: 185˚F
Exhaust System
- Type: Air Cooled Manifold
- Max Allowable Back Pressure: 10.2 kPa
- Cont. Rating Catalyst Configuration: No Catalyst
- Exhaust Gas Flow at Rated Power @ 1350˚F: 361.9 cfm
Air Intake System
- Combustion Air Required: 112.1 cfm
- Max Intake Air Restriction (Clean Element): 1.49 kPa / 3 inH2O
- Air Filter Type: Dry Paper Element
Lubrication System
- Oil Specifications: SAE 5W-30 API Rating SM or Newer
- Oil Pan Capacity: 4.5 Qts
- Oil Filter; Qt, Type: 1, Cartridge
- Max Allowable Oil Temp: 250˚F
Alternator Data
- Manufacturer: Stamford
- Standards: BS EN 60034
- Control System: PMG
- A.V.R.: MX341
- Voltage Regulation: ± 1 %
- Insulation System: Class H
- Protection: IP23
- Rated Power Factor: 0.8
- Stator Winding: Double Layer Concentric
- Winding Pitch: Two Thirds
- Winding Leads: 12
- Telephone Interference: THF < 2 %
- Waveform Distortion: No Load < 1.5 %
- Maximum Overspeed: 2250 rev/min
Controller Data
- Manufacturer: DSE
- Model: 7320 MK II
Controller Features & Benefits
- Microprocessor controlled, UL & NFPA110 Compatible
- License free PC Software (Non-proprietary Software)
- IP65 rating offers increased resistance to water ingress
- Modules can be integrated to building management systems
- Real time clock provides accurate event log
- Four line back-lit LCD text display
- Five key menu navigation, two wire start/stop at Auto mode
- Front panel editing with PIN protection
- Support up to three remote display modules
- Configurable timers and alarms
- Multiple date and timer scheduler
- Integral PLC editor
- 'Protections disabled' feature
- Load switching (load shedding and dummy load outputs)
- Fully configurable via DSE Configuration Suite PC Software
- SCADA monitoring via DSE Configuration Suite PC Software
Protection & Instruments
- Gen. Voltage – under / over; Gen. Voltage (L-L/L-N)
- Gen. Freq. – under / over; Gen. Frequency
- Engine Speed – under / over; Engine speed
- Engine Oil Pressure – low; Oil Pressure
- Engine Temp – low / high; Water Temperature
- Battery Voltage – low / high; Battery Voltage
- Weak Battery; Run Time
- Fail to Start / Stop; Phase Sequence
- Charge Alternator Fail; Power monitoring (kWh/kVAh/kVArh)
- Over Current & Load (kW/kVAr); Power (kWh/kVAh/kVArh)
- Unbalanced Load; Power Factor
- Independent Earth Fault; Generator Current
- Reverse Power; Generator Load (%)
- Loss of Speed Signal; Earth Current
Battery Charger & Electrical System Data
- Manufacturer: ComAp
- Model: InteliCharger
- Input Voltage: 85V ~ 264V AC
- Output Voltage / Current: 13.8V Float / 4A pk
Jacket Water Heater Data
- Manufacturer: Hotstart
- Model: TPS101GT10-000
- Input Voltage: 120V
- Power: 1000W
Enclosure Features
- Heavy Duty Steel / Aluminum Structure
- E-Stop on Enclosure
- Control Panel Eliminated from Engine Vibrations
- Standard Sound Attenuation Foam
- Plastic Covered Corrosion Resistant Locks & Hinges
- Internally Mounted Exhaust System with Rain Cap
- Coolant Fill Cap
- Removable Base Frame Lifting Hooks
- Oil & Coolant Drain Ports
- Easy Access for Maintenance
Dimensions & Weight
- Open Skid: Length 72 in, Width 39 in, Height 38 in, Dry Weight 1600 lbs.
- Enclosed Level 1: Length 89 in, Width 39 in, Height 56 in, Dry Weight 2300 lbs., Sound Pressure @ 7m 69 dBA
- Enclosed Level 2: Length 89 in, Width 39 in, Height 69 in, Dry Weight 2600 lbs., Sound Pressure @ 7m 65 dBA
Standard Features & Accessories
- UL2200 Certification
- Heavy Duty Steel Base Frame
- PMG
- Engine Jacket Water Heater
- Battery and Battery Rack
- Battery Charger
- Anti Vibration Pads between Engine/Alternator & Base Frame
- Critical Grade Silencer Inside Enclosure
- Residential Grade Silencer Set for Open Skid Sets
- Exhaust outlet rain cap and radiator fill cap
- Sound Absorb Foam Material for Enclosure
- Emergency Stop Button
- Oil Drain Valve
- Coolant Drain Valve
- Jacket Water Heater Isolation Valves
- Flex Fuel Lines
- Secondary Lock-off Valve on Baseframe
- Engine Manifold Cover
- Turbocharger Cover
- Protection Covers for Rotating Parts
- Exhaust Insulation Cover
- Enclosure DC Light
- Operations Manual
- 24 Months / 2000 hours Limited Standby Warranty
Optional Accessories
- Main Line CB (3 / 4 Poles – 80% / 100% rated)
- Upsize Alternator
- Anti-condensation Heater
- Voltage Regulation ±0.5% w/MX321 AVR
- Gas Regulator
- NG / LP Auto Changeover Control System
- Low Gas Pressure Alarm
- Low Coolant Level Alarm
- Oil Pan Heater
- Oil Temperature Display on Controller
- Manual Speed Adjust Rheostat
- Manual Voltage Adjust Rheostat
- Remote Annunciator Panel
- Remote Control & Monitoring Panel
- Advanced SMS Messaging
- Control Panel Heater
- Battery Disconnect Switch
- Battery Heater
- Battery Charger 10/20 Amp
- Shunt Trip / Aux Contacts
- Spring Anti-vibration Isolators
- Automatic Transfer Panel (ATS)
- 5 Years / 2000 hours Limited Comprehensive Warranty
Codes & Standards
- Designed and manufactured in a facility certified to ISO9001
- Designed and manufactured in a facility certified to ISO14001:2015
- AKSA Power Generation provides single source responsibility for the generator set & accessories
- Prototype tested and production tested according to the UL test program
- Meets NFPA70, 99, 110, 37 Level 1 when equipped with the necessary accessories and installed per NFPA standards (engine must have a fast start kit for NFPA110 Level 1)
product specifications:
| Specification | Value |
| Model Name | APD-NG40 |
| Engine Make | PSI |
| Engine Model | 4.3L |
| Alternator Make | Stamford |
| Control Panel Make & Model | DSE 7320 MK II |
| Frequency & Speed | 60 Hz, 1800 rpm |
| Enclosure Make & Model | AKSA AUL 31/32 |
| NG Standby Power | 40 kW |
| LP Gas Standby Power | 40 kW |
| Rated Power Factor | 0.8 |
| Engine Displacement & Cylinders | 4.3L / 6 Cylinders |
| Engine Type | V-type, 4 Cycle |
| Engine Speed | 1800 rpm |
| Engine Standby Power NG | 58.18 kW |
| Engine Standby Power LP | 61.27 kW |
| Aspiration | Naturally Aspired |
| Compression Ratio | 9.4 : 1 |
| Bore / Stroke | 101.6 mm / 88 mm |
| Governor Type | Electronic |
| Fuel Type | NG, LP Gas / Dual Fuel |
| Min NG Supply Pipe Size | 1-1/4" NPTF |
| Min LPG Supply Pipe Size | 3/4" |
| Maximum EPR Rated Pressure | 6.9 kPa / 1.0 psi |
| Max Pressure to EPR | 2.7 kPa / 11.0 inH2O |
| Min Pressure to EPR | 1.7 kPa / 7.0 inH2O |
| Fuel Consumption, Standby 100% (NG) | 600 cfh / 17.0 m3/hr |
| Fuel Consumption, Standby 100% (LP) | 245 cfh / 6.9 m3/hr |
| System Voltage (DC) | 12V |
| Battery Qty, Rating | 1 x 54Ah |
| Radiator Cooling System Type | Closed Circuit |
| Coolant Capacity, Engine Only | 7.75 quart |
| Cranking Temperature | 160 F |
| Full Open Temperature | 185 F |
| Exhaust Type | Air Cooled Manifold |
| Max Allowable Back Pressure | 10.2 kPa |
| Exhaust Gas Flow at Rated Power @ 1350 F | 361.9 cfm |
| Combustion Air Required | 112.1 cfm |
| Max Intake Air Restriction (Clean Element) | 1.49 kPa / 3 inH2O |
| Air Filter Type | Dry Paper Element |
| Oil Specifications | SAE 5W-30 API Rating SM or Newer |
| Oil Pan Capacity | 4.5 Qts |
| Oil Filter; Qt, Type | 1, Cartridge |
| Max Allowable Oil Temp | 250 F |
| Alternator Standards | BS EN 60034 |
| Alternator Control System | PMG |
| A.V.R. | MX341 |
| Voltage Regulation | ± 1 % |
| Insulation System | Class H |
| Alternator Protection | IP23 |
| Stator Winding | Double Layer Concentric |
| Winding Pitch | Two Thirds |
| Winding Leads | 12 |
| Telephone Interference | THF < 2 % |
| Waveform Distortion | No Load < 1.5 % |
| Maximum Overspeed | 2250 rev/min |
| Controller Manufacturer | DSE |
| Controller Model | 7320 MK II |
| Battery Charger Manufacturer | ComAp |
| Battery Charger Model | InteliCharger |
| Battery Charger Input Voltage | 85V ~ 264V AC |
| Battery Charger Output Voltage / Current | 13.8V Float / 4A pk |
| Jacket Water Heater Manufacturer | Hotstart |
| Jacket Water Heater Model | TPS101GT10-000 |
| Jacket Water Heater Input Voltage | 120V |
| Jacket Water Heater Power | 1000W |
| Open Skid Length | 72 in |
| Open Skid Width w/o Lift Hooks | 39 in |
| Open Skid Height | 38 in |
| Open Skid Dry Weight | 1600 lbs. |
| Enclosed Level 1 Length | 89 in |
| Enclosed Level 1 Width w/o Lift Hooks | 39 in |
| Enclosed Level 1 Height | 56 in |
| Enclosed Level 1 Dry Weight | 2300 lbs. |
| Enclosed Level 1 Sound Pressure @ 7 meters | 69 dBA |
| Enclosed Level 2 Length | 89 in |
| Enclosed Level 2 Width w/o Lift Hooks | 39 in |
| Enclosed Level 2 Height | 69 in |
| Enclosed Level 2 Dry Weight | 2600 lbs. |
| Enclosed Level 2 Sound Pressure @ 7 meters | 65 dBA |
| Certification | UL2200 |
| Standards Met | NFPA 70, 99, 110 (Level 1), 37 |
| Warranty | 24 Months / 2000 Hours Limited Standby |
product related documents:
| Peso | 2600 lbs |
|---|---|
| Dimensiones | 89 × 39 × 69 in |
Solo los usuarios registrados que hayan comprado este producto pueden hacer una valoración.





Valoraciones
No hay valoraciones aún.