General characteristics 

  • This product is only for export outside USA
  • Engine brand                 VOLVO 
  • Engine type                    TAD1641GE-B1 
  • Performance class       G3 
  • Frequency (Hz)             60 Hz 
  • Standard Voltage (V)  208/120 – (twelve-lead reconnectable stator) 
  • Standard Control Panel APM403 

Descriptive 

  • Electronic governor  
  • Mechanically welded chassis with antivibration suspension  
  • Highly durable QUALICOAT-certified epoxy paint, specially developed for KOHLER-SDMO 
  • Main line circuit breaker  
  • Radiator for core temperature of 48/50°C max with mechanical fan  
  • Starting battery  
  • 24 V charge alternator and starter  
  • Delivered with oil and coolant -30°C  
  • Manual for use and installation 

Out of stock

Share:
Description
Additional Info
Reviews
Description

KOHLER SDMO V500UC2

Details and Specifications

Benefits & features 

KOHLER SDMO premium quality 

  • Design offices using the latest technical innovations 
  • Modern fully certified factories 
  • A cutting edge laboratory 
  • The generating set, its components and a wide range of options have been fully developed, prototype tested, factory built, and production tested 

KOHLER SDMO premium performances 

  • Optimized and certified sound levels 
  • Reliable power, even in extreme conditions 
  • Optimized fuel consumption 
  • Compact footprint 
  • Best quality of electricity, high starting and loading capacity, according to ISO8528-5 
  • Robust base frames and high-quality enclosures 
  • Protection of installations and people 
  • Approved in line with the most stringent standards 

Engines 

  • Premium level engines, in-house or from strong partners 
  • High power density, small footprint 
  • Low temperature starting capability 
  • Long maintenance interval 

Alternator 

  • Provide industry leading motor starting capability 
  • Made in Europe 
  • Built with a class H insulation and IP23 

Cooling 

  • A compact and complete solution using a mechanically driven radiator fan 
  • Designed or optimized by KOHLER-SDMO 
  • High temperature and altitude product capacity available 

Base frame and enclosure 

  • High quality steel with enhanced corrosion resistance 
  • Highly durable QUALICOAT-certified epoxy paint 
  • Minimum 1000 hours of resistance to salt spray in accordance with ISO12944 
  • Ergonomic access to allow easy maintenance and connection of the generator  
  • Robust design optimized for transportation

Product Specifications:

Generator modelV500UC2
Standard Voltage208/120
Hz60
Amps @ 208V1735
Standby Power (ESP)500kW /625KVA
Prime Power (PRP)454kW / 568KVA
Fuel Consumption 60 Hz Diesel at 75% Prime Power: Lph91.2
Tank capacity (L)500
Soundproofed Enclosure typeM229
Acoustic pressure level @7m in dB(A) 60Hz (100% PRP)76
Engine Specifications
Engine modelTAD1641GE-B
Displacement (L)16,12
Cyl. qty.6L
GovernorElectronic
TypeTurbo
Alternator Specifications
Number of poles4
Number of bearingSingle Bearing
TechnologyBrushless
Indication of protectionIP23
Insulation classH
Number of wires12
AVR RegulationYes
CouplingDirect
Capacity for maintaining short circuit at 300% of rated current for 10 sNo

 

Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit. Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield different results. Data and specifications subject to change without notice.

Controller Specifications

BASIC GENERATING SET AND POWER PLANT CONTROL

The APM403 is a versatile control unit which allows operation in manual or automatic mode

  • Measurements : voltage and current
  • kW/kWh/kVA power meters
  • Standard specifications: Voltmeter, Frequency meter.
  • Optional : Battery ammeter.
  • J1939 CAN ECU engine control
  • Alarms and faults: Oil pressure, Coolant temperature, Overspeed, Start-up failure, alternator min/max, Emergency stop button.
  • Engine parameters: Fuel level, hour counter, battery voltage.
  • Optional (standard at 24V): Oil pressure, water temperature.
  • Event log/ Management of the last 300 genset events.
  • Mains and genset protection
  • Clock management
  • USB connections, USB Host and PC,
  • Communications : RS485 INTERFACE
  • ModBUS protocol /SNMP
  • Optional : Ethernet, GPRS, remote control, 3G, 4G,
  • Websupervisor, SMS, E-mails

PRODUCT Related documents:

APM403 brochure

Control Panel APM403_EN

V0500UC2-02-EN

APM403S Product presentation

data canopy M229 V0500UC2-02-EN

Full line brochure MK-IN-FL-BR-EN-221

M229 enclosure concrete slab drawing 35002015204-B

M229 Soundproofed version drawing 30001349101K

Additional Info
Weight10737 lbs
Dimensions198 × 61 × 96 in
Reviews

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Item added to cart View Cart Checkout
Item added to wishlist View Wishlist
Item removed from wishlist