Aksa Diesel Generator APD-ULJ80 (80kW)



Aksa Diesel Generator APD-ULJ80 (80kW)
Call for Price
The APD-ULJ80 is a UL2200-certified diesel standby generator set from AKSA Power Generation, built around a John Deere 4045HF285 turbocharged diesel engine and a Stamford brushless alternator. Configurable for standby output from 75 kW to 80 kW at 60 Hz across multiple voltage options, the unit is managed by a DSE 7320 MK II digital control panel and is available on an open skid or in Level 1 and Level 2 sound-attenuated enclosures. Designed for emergency stationary power in commercial and industrial settings, the APD-ULJ80 is engineered to meet NFPA 70, 99, 110, and 37 Level 1 requirements when installed with the necessary accessories.
Key Features
- UL2200 certified diesel generator set
- John Deere 4045HF285 turbocharged diesel engine, calibrated to EPA Tier 3
- Stamford UCI224/274 brushless alternator with Class H insulation and PMG excitation
- DSE 7320 MK II microprocessor-controlled digital control panel with UL & NFPA 110 compatibility
- Standby power ratings from 75 kW to 80 kW at 60 Hz, multiple voltage configurations available
- Available as open skid or in Level 1 and Level 2 sound-attenuated enclosures
- Meets NFPA 70, 99, 110, and 37 Level 1 standards when properly installed
- Engine jacket water heater, battery, and battery charger included standard
- Heavy duty steel base frame with anti-vibration pads between engine, alternator, and frame
- 24 months / 2000 hours limited standby warranty
APD-ULJ80 Details & Specifications:
General Characteristics
- Model Name: APD-ULJ80
- Engine Make: John Deere
- Engine Model: 4045HF285
- Alternator Make: Stamford
- Control Panel Make & Model: DSE 7320 MK II
- Frequency & Speed: 60 Hz, 1800 rpm
- Enclosure Make & Model: AKSA AUL 41/42
- Certification: UL2200 Diesel
Genset Rating
- 480/277V, 3-phase — 80 kW standby, 0.8 PF, 120A standby current (UCI224G, Wnd-311)
- 240/120V, 1-phase — 75 kW standby, 1.0 PF, 312A standby current (UCI224G, Wnd-06)
- 208/120V, 3-phase — 75 kW standby, 0.8 PF, 260A standby current (UCI224G, Wnd-311)
- 600/347V, 3-phase — 75 kW standby, 0.8 PF, 90A standby current (UCI224F, Wnd-17)
- 240/120V, 3-phase — 75 kW standby, 0.8 PF, 225.6A standby current (UCI224G, Wnd-311)
- 240/120V, 3-phase — 80 kW standby, 0.8 PF, 240.9A standby current (UCI274C, Wnd-311)
Engine Data
- Manufacturer: John Deere
- Model: 4045HF285
- Displacement & Cylinders: 4.5 L / 4 Cylinders
- Engine Type: In-line, 4 Cycle
- Engine Speed: 1800 rpm
- Engine Prime Power: 86 kW
- Engine Standby Power: 94 kW
- Aspiration: Turbocharged
- Compression Ratio: 19.0 : 1
- Bore / Stroke: 106 mm / 127 mm
- Governor Type: Electronic
- Engine Crankcase Vent System: Open
- Ratio, Air : Fuel: 21 : 1
- BMEP, Standby Power: 1748 kPa
- Friction Power: 13 kW
- Designed / Calibrated to Meet: EPA Tier 3
Fuel System
- ECU Description: L16 Control
- Max. Fuel Inlet Temp.: 176 °F
- Total Fuel Flow: 111 lb/hr
- Fuel Consumption @ 100% Standby: 6.60 gal/h
- Fuel Consumption @ 75% Standby: 5.36 gal/h
- Fuel Consumption @ 50% Standby: 3.95 gal/h
- Fuel Consumption @ 25% Standby: 2.14 gal/h
Electric System
- System Voltage: 12V
- Min Voltage at ECU during Crank: 6V
- Battery Qty, Rating: 1 x 60Ah
Cooling System
- Radiator Cooling System Type: Closed Circuit
- Radiator Ambient Temp: > 50 °C
- Coolant Capacity, Engine Only: 9 quart
- Max Top Tank Temp: 230 °F
- Thermostat, Start – Fully Open: 180–203 °F
Exhaust & Air Intake System
- Exhaust Temperature: 1069 °F
- Max Allowable Exhaust Restriction: 7.5 kPa
- Exhaust Gas Flow: 651 ft.³/min
- Engine Air Flow: 234 ft.³/min
- Max Intake Air Restriction (Clean Element): 3.75 kPa
- Air Filter Type: Dry Paper Element
Lubrication System
- Oil Pressure at Rated Speed: 320 kPa
- Oil Pressure at Low Idle: 105 kPa
- Max Oil Carryover in Blow-by: 0.002 lb/hr
- Max Crankcase Pressure: 0.5 kPa
Alternator Data
- Manufacturer: Stamford
- Standards: BS EN 60034
- Control System: PMG
- A.V.R.: MX341
- Voltage Regulation: ± 1%
- Insulation System: Class H
- Protection: IP23
- Rated Power Factor: 0.8
- Stator Winding: Double Layer Concentric
- Winding Pitch: Two Thirds
- Winding Leads: 12
- Telephone Interference: THF < 2%
- Waveform Distortion: No Load < 1.5%
- Maximum Over Speed: 2250 rev/min
Controller Data
- Manufacturer: DSE
- Model: 7320 MK II
- Microprocessor controlled, UL & NFPA110 Compatible
- License free PC Software (Non-proprietary Software)
- IP65 rating offers increased resistance to water ingress
- Modules can be integrated to building management systems
- Real time clock provides accurate event log
- Four line back-lit LCD text display
- Five key menu navigation, two wire start/stop at Auto mode
- Front panel editing with PIN protection
- Support up to three remote display modules
- Configurable timers and alarms
- Multiple date and timer scheduler
- Integral PLC editor
- 'Protections disabled' feature
- Load switching (load shedding and dummy load outputs)
- Fully configurable via DSE Configuration Suite PC Software
- SCADA monitoring via DSE Configuration Suite PC Software
Protection & Instruments
- Gen. Voltage – under / over; Gen. Voltage (L-L/L-N)
- Gen. Frequency – under / over
- Engine Speed – under / over
- Engine Oil Pressure – low
- Engine Temp – low / high (Water Temperature)
- Battery Voltage – low / high
- Weak Battery / Run Time
- Fail to Start / Stop / Phase Sequence
- Charge Alternator Fail
- Power monitoring (kWh/kVAh/kVArh)
- Over Current & Load (kW/kVAr) / Power (kWh/kVAh/kVArh)
- Unbalanced Load / Power Factor
- Independent Earth Fault / Generator Current
- Reverse Power / Generator Load (%)
- Loss of Speed Signal / Earth Current
Battery Charger & Electrical System Data
- Manufacturer: ComAp
- Model: InteliCharger
- Input Voltage: 85V ~ 264V AC
- Output Voltage / Current: 13.8V Float / 4A pk
Jacket Water Heater Data
- Manufacturer: Hotstart
- Model: TPS101GT10-000
- Input Voltage: 120V
- Power: 1000W
Enclosure & Dimensions
- Open Skid: 92.1 in (L) x 43.3 in (W) x 53.5 in (H); Dry Weight 2600 lbs.
- Level 1 Enclosure: 116.5 in (L) x 43.3 in (W) x 66.3 in (H); Dry Weight 3800 lbs.; Sound Pressure @ 7m: 70 dB(A)
- Level 2 Enclosure: 116.5 in (L) x 43.3 in (W) x 82 in (H); Dry Weight 4100 lbs.; Sound Pressure @ 7m: 67 dB(A)
- Heavy Duty Steel / Aluminum Structure
- E-Stop on Enclosure
- Control Panel Eliminated from Engine Vibrations
- Standard Sound Attenuation Foam
- Plastic Covered Corrosion Resistant Locks & Hinges
- Internally Mounted Exhaust System with Rain Cap
- Coolant Fill Cap
- Removable Base Frame Lifting Hooks
- Oil & Coolant Drain Ports
- Easy Access for Maintenance
Fuel Tank — UL142 Listed Base Design
- 24hr Tank: 160 gal; 130 x 43.3 x 13.5 in; Weight 1190 lbs.
- 48hr Tank: 350 gal; 130 x 43.3 x 26 in; Weight 1650 lbs.
- 72hr Tank: 485 gal; 130 x 43.3 x 34 in; Weight 1930 lbs.
Standard Features & Accessories
- UL2200 Certification
- Heavy Duty Steel Base Frame
- PMG w/MX341 AVR
- Engine Jacket Water Heater
- Battery and Battery Rack
- Battery Charger
- Anti Vibration Pads between Engine/Alternator & Base Frame
- Critical Grade Silencer Inside Enclosure
- Residential Grade Silencer Set for Open Skid Sets
- Exhaust Outlet Rain Cap and Radiator Fill Cap
- Sound Absorb Foam Material for Enclosure
- Emergency Stop Button
- Oil Drain Valve
- Coolant Drain Valve
- Jacket Water Heater Isolation Valves
- Flex Fuel Lines
- Air Filter Restriction Gauge
- Engine Manifold Cover
- Turbocharger Cover
- Protection Covers for Rotating Parts
- Exhaust Insulation Cover
- Enclosure DC Light
- Operations Manual
- 24 Months / 2000 hours Limited Standby Warranty
Optional Accessories
- Main Line CB (3 / 4 Poles – 80% / 100% rated)
- Upsize Alternator
- Voltage Regulation ± 0.5% w/MX321 AVR
- Anti-condensation Heater
- Sub Base Fuel Tank (UL142 / UL2085)
- Fuel Level Display & Alarm on Controller
- Low / High Fuel Alarms
- Fuel Water Separator Filter
- Auto Fuel Fill Control System
- Oil Temperature Display on Controller
- Manual Speed Adjust Rheostat
- Manual Voltage Adjust Rheostat
- Remote Annunciator Panel
- Remote Control & Monitoring Panel
- Advanced SMS Messaging
- Control Panel Heater
- Battery Disconnect Switch
- Battery Heater
- Battery Charger 10/20 Amp
- Shunt Trip / Aux Contacts
- Spring Anti-vibration Isolators
- Automatic Transfer Panel (ATS)
- 5 Years / 2000 hours Limited Comprehensive Warranty
Codes & Standards
- Designed and manufactured in a facility certified to ISO9001 standards
- Designed and manufactured in a facility certified to ISO14001:2015 standards
- AKSA Power Generation provides single source responsibility for the generator set & accessories
- Prototype tested and production tested according to the UL test program
- Meets NFPA70, 99, 110, 37 Level 1 when equipped with the necessary accessories and installed per NFPA standards
product specifications:
| Specification | Value |
| Model Name | APD-ULJ80 |
| Engine Make | John Deere |
| Engine Model | 4045HF285 |
| Alternator Make | Stamford |
| Control Panel Make & Model | DSE 7320 MK II |
| Frequency & Speed | 60 Hz, 1800 rpm |
| Enclosure Make & Model | AKSA AUL 41/42 |
| Standby Power (480/277V, 3ph) | 80 kW |
| Standby Power (240/120V, 1ph) | 75 kW |
| Standby Power (208/120V, 3ph) | 75 kW |
| Standby Power (600/347V, 3ph) | 75 kW |
| Standby Power (240/120V, 3ph) | 75 kW |
| Standby Power (240/120V, 3ph, UCI274C) | 80 kW |
| Power Factor | 0.8 (1.0 for single phase) |
| Engine Displacement & Cylinders | 4.5 L / 4 Cylinders |
| Engine Type | In-line, 4 Cycle |
| Engine Speed | 1800 rpm |
| Engine Prime Power | 86 kW |
| Engine Standby Power | 94 kW |
| Aspiration | Turbocharged |
| Compression Ratio | 19.0 : 1 |
| Bore / Stroke | 106 mm / 127 mm |
| Governor Type | Electronic |
| Emissions Certification | EPA Tier 3 |
| Fuel System ECU | L16 Control |
| Total Fuel Flow | 111 lb/hr |
| Fuel Consumption @ 100% Standby | 6.60 gal/h |
| Fuel Consumption @ 75% Standby | 5.36 gal/h |
| Fuel Consumption @ 50% Standby | 3.95 gal/h |
| Fuel Consumption @ 25% Standby | 2.14 gal/h |
| System Voltage | 12V |
| Battery Qty, Rating | 1 x 60Ah |
| Cooling System Type | Closed Circuit |
| Coolant Capacity (Engine Only) | 9 quart |
| Alternator Standards | BS EN 60034 |
| Alternator Control System | PMG |
| A.V.R. | MX341 |
| Voltage Regulation | ± 1% |
| Insulation System | Class H |
| Alternator Protection Rating | IP23 |
| Rated Power Factor | 0.8 |
| Controller Manufacturer | DSE |
| Controller Model | 7320 MK II |
| Battery Charger Manufacturer | ComAp |
| Battery Charger Model | InteliCharger |
| Jacket Water Heater Manufacturer | Hotstart |
| Jacket Water Heater Model | TPS101GT10-000 |
| Jacket Water Heater Power | 1000W |
| Open Skid Length | 92.1 in |
| Open Skid Width (w/o lift hooks) | 43.3 in |
| Open Skid Height | 53.5 in |
| Open Skid Dry Weight | 2600 lbs. |
| Level 1 Enclosure Length | 116.5 in |
| Level 1 Enclosure Width (w/o lift hooks) | 43.3 in |
| Level 1 Enclosure Height | 66.3 in |
| Level 1 Enclosure Dry Weight | 3800 lbs. |
| Level 1 Sound Pressure @ 7 meters | 70 dB(A) |
| Level 2 Enclosure Length | 116.5 in |
| Level 2 Enclosure Width (w/o lift hooks) | 43.3 in |
| Level 2 Enclosure Height | 82 in |
| Level 2 Enclosure Dry Weight | 4100 lbs. |
| Level 2 Sound Pressure @ 7 meters | 67 dB(A) |
| Fuel Tank 24hr Capacity | 160 gal |
| Fuel Tank 24hr Weight | 1190 lbs. |
| Fuel Tank 48hr Capacity | 350 gal |
| Fuel Tank 48hr Weight | 1650 lbs. |
| Fuel Tank 72hr Capacity | 485 gal |
| Fuel Tank 72hr Weight | 1930 lbs. |
| Warranty | 24 Months / 2000 hours Limited Standby |
product related documents:
| Peso | 4100 lbs |
|---|---|
| Dimensiones | 116.5 × 43.3 × 82 in |
Solo los usuarios registrados que hayan comprado este producto pueden hacer una valoración.





Valoraciones
No hay valoraciones aún.