The AKSA APD-ULJ65 is a UL2200-listed diesel standby generator set rated at 65 kW / 81 kVA standby power, built around a John Deere 4045HF280 industrial diesel engine paired with a Stamford UCI224F brushless alternator. Engineered for reliable emergency and standby power in commercial and industrial applications, the unit is managed by a DSE 7320 MK II controller and is available in open skid, Level 1, or Level 2 sound-attenuated enclosure configurations. The genset meets NFPA 70, 99, 110, and 37 Level 1 requirements when installed with the necessary accessories, and is EPA-certified for emergency stationary applications, offering dependable performance backed by AKSA’s over 30 years of generator manufacturing experience.
Key Features
- UL2200 Certified, 65 kW / 81 kVA standby power output
- John Deere 4045HF280 diesel engine – EPA Tier 3 calibrated
- Stamford UCI224F alternator with MX341 AVR, Class H insulation
- DSE 7320 MK II microprocessor controller, UL & NFPA110 compatible
- Meets NFPA 70, 99, 110, and 37 Level 1 standards
- Available in Open Skid, Level 1, or Level 2 sound-attenuated enclosures
- Multiple voltage configurations: 480/277V, 240/120V (1ph & 3ph), 208/120V, 600/347V
- Engine Jacket Water Heater and Battery Charger included as standard
- Heavy Duty Steel/Aluminum enclosure structure with E-Stop and sound-absorbing foam
- 24 Months / 2,000 hours limited standby warranty
APD-ULJ65 product details and specifications:
General Characteristics
- Model Name: APD-ULJ65
- Engine Make: John Deere
- Engine Model: 4045HF280
- Alternator Make: Stamford
- Control Panel Make & Model: DSE 7320 MK II
- Frequency & Speed: 60Hz, 1800rpm
- Enclosure Make & Model: AKSA AUL 41/42
Genset Rating
- Standby Power (480/277V): 65 kW, 0.8 PF, 98A
- Standby Power (240/120V, 1ph): 60 kW, PF 1, 250A
- Standby Power (208/120V): 65 kW, 0.8 PF, 224A
- Standby Power (600/347V): 65 kW, 0.8 PF, 78A
- Standby Power (240/120V): 65 kW, 0.8 PF, 194.3A
Engine Data
- Manufacturer: John Deere
- Model: 4045HF280
- Displacement & Cylinders: 4.5 L / 4 Cylinders
- Engine Type: In-line, 4 Cycle
- Engine Speed: 1800 rpm
- Engine Prime Power: 67 kW
- Engine Standby Power: 74 kW
- Aspiration: Intercooled
- Compression Ratio: 19.0 : 1
- Bore / Stroke: 106 mm / 127 mm
- Governor Type: Mechanical
- Engine Crankcase Vent System: Open
- Ratio, Air : Fuel: 22 : 1
- BMEP, Standby Power: 1090 kPA
- Friction Power: 13 kW
- Designed / Calibrated to Meet: EPA Tier 3
Fuel System
- Combustion System: Direct Injection
- Max Fuel Inlet Temp.: 176 °F
- Total Fuel Flow: 212 lb/hr
Fuel Consumption
- Standby Power (100%): 5.11 gal/h
- Standby Power (75%): 3.94 gal/h
- Standby Power (50%): 2.78 gal/h
- Standby Power (25%): 1.54 gal/h
Electric System
- System Voltage: 12V
- Starter Rolling Current @ 32°F: 780 Amps
- Battery Qty, Rating, CCA: 1 x 60Ah
Cooling System
- Radiator Cooling System Type: Closed Circuit
- Radiator Ambient Temp: > 50 °C
- Coolant Capacity, Engine Only: 9 quart
- Max Top Tank Temp: 221 °F
- Thermostat, Start – Fully Open: 180–202 °F
Exhaust System
- Exhaust Temperature: 1139 °F
- Max Allowable Exhaust Restriction: 7.5 kPa
- Exhaust Gas Flow: 508 ft.3/min
- Engine Air Flow: 191 ft.3/min
- Max Intake Air Restriction (Clean Element): 3.0 kPa
- Air Filter Type: Dry Paper Element
Lubrication System
- Oil Pressure at Rated Speed: 345 kPa
- Oil Pressure at Low Idle: 105 kPa
- Max Oil Carryover in Blow-by: 0.002 lb/hr
- Max Crankcase Pressure: 0.5 kPa
Alternator Data
- Manufacturer: Stamford
- Standards: BS EN 60034
- Control System: PMG
- A.V.R.: MX341
- Voltage Regulation: ± 1 %
- Insulation System: Class H
- Protection: IP23
- Rated Power Factor: 0.8
- Stator Winding: Double Layer Concentric
- Winding Pitch: Two Thirds
- Winding Leads: 12
- Telephone Interference: THF < 2 %
- Waveform Distortion: No Load < 1.5 %
- Maximum Overspeed: 2250 rev/min
Battery Charger & Electrical System Data
- Manufacturer: ComAp
- Model: InteliCharger
- Input Voltage: 85V ~ 264V AC
- Output Voltage / Current: 13.8V Float / 4A pk
Jacket Water Heater Data
- Manufacturer: Hotstart
- Model: TPS101GT10-000
- Input Voltage: 120V
- Power: 1000W
Controller Data
- Manufacturer: DSE
- Model: 7320 MK II
Controller Features & Benefits
- Microprocessor controlled, UL & NFPA110 Compatible
- License free PC Software (Non-proprietary Software)
- IP65 rating offers increased resistance to water ingress
- Modules can be integrated to building management systems
- Real time clock provides accurate event log
- Four line back-lit LCD text display
- Five key menu navigation, two wire start/stop at Auto mode
- Front panel editing with PIN protection
- Support up to three remote display modules
- Configurable timers and alarms
- Multiple date and timer scheduler
- Integral PLC editor
- ‘Protections disabled’ feature
- Load switching (load shedding and dummy load outputs)
- Fully configurable via DSE Configuration Suite PC Software
- SCADA monitoring via DSE Configuration Suite PC Software
Protection
- Gen. Voltage – under / over
- Gen. Freq. – under / over
- Engine Speed – under / over
- Engine Oil Pressure – low
- Engine Temp – low / high
- Battery Voltage – low / high
- Weak Battery
- Fail to Start / Stop
- Charge Alternator Fail
- Over Current & Load (kW/kVAr)
- Unbalanced Load
- Independent Earth Fault
- Reverse Power
- Loss of Speed Signal
Instruments
- Gen. Voltage (L-L/L-N)
- Gen. Frequency
- Engine speed
- Oil Pressure
- Water Temperature
- Battery Voltage
- Run Time
- Phase Sequence
- Power monitoring (kWh/kVAh/kVArh)
- Power (kWh/kVAh/kVArh)
- Power Factor
- Generator Current
- Generator Load (%)
- Earth Current
Enclosure Features
- Heavy Duty Steel / Aluminum Structure
- E-Stop on Enclosure
- Control Panel Eliminated from Engine Vibrations
- Standard Sound Attenuation Foam
- Plastic Covered Corrosion Resistant Locks & Hinges
- Internally Mounted Exhaust System with Rain Cap
- Coolant Fill Cap
- Removable Base Frame Lifting Hooks
- Oil & Coolant Drain Ports
- Easy Access for Maintenance
Dimensions & Weight
- Open Skid – Length / Width / Height: 92.1 in / 43.3 in / 53.5 in
- Open Skid – Dry Weight: 2400 lb
- Level 1 Enclosure – Length / Width / Height: 116.5 in / 43.3 in / 66.3 in
- Level 1 Enclosure – Dry Weight: 3600 lb
- Level 1 Enclosure – Sound Pressure @ 7m: 71 dB(A)
- Level 2 Enclosure – Length / Width / Height: 116.5 in / 43.3 in / 82 in
- Level 2 Enclosure – Dry Weight: 3900 lb
- Level 2 Enclosure – Sound Pressure @ 7m: 67 dB(A)
Fuel Tank (UL142 Listed Base Design)
- 24hr Tank (130 gal) – Dimensions / Weight: 130 / 43.3 / 12 in – 1130 lb
- 48hr Tank (260 gal) – Dimensions / Weight: 130 / 43.3 / 20 in – 1420 lb
- 72hr Tank (390 gal) – Dimensions / Weight: 130 / 43.3 / 28.5 in – 1750 lb
Standard Features & Accessories
- UL2200 Certification
- Heavy Duty Steel Base Frame
- PMG w/MX341 AVR
- Engine Jacket Water Heater
- Battery and Battery Rack
- Battery Charger
- Anti Vibration Pads between Engine/Alternator & Base Frame
- Critical Grade Silencer Inside Enclosure
- Residential Grade Silencer Set for Open Skid Sets
- Exhaust outlet rain cap and radiator fill cap
- Sound Absorb Foam Material for Enclosure
- Emergency Stop Button
- Oil Drain Valve
- Coolant Drain Valve
- Jacket Water Heater Isolation Valves
- Flex Fuel Lines
- Air Filter Restriction Gauge
- Engine Manifold Cover
- Turbocharger Cover
- Protection Covers for Rotating Parts
- Exhaust Insulation Cover
- Enclosure DC Light
- Operations Manual
- 24 Months / 2000 hours Limited Standby Warranty
Optional Accessories
- Main Line CB (3/4 Poles – 80% / 100% rated)
- Upsize Alternator
- Voltage Regulation ±0.5% w/MX321 AVR
- Anti-condensation Heater
- Sub Base Fuel Tank (UL142 / UL2085)
- Fuel Level Display & Alarm on Controller
- Low / High Fuel Alarms
- Fuel Water Separator Filter
- Auto Fuel Fill Control System
- Oil Temperature Display on Controller
- Manual Speed Adjust Rheostat
- Manual Voltage Adjust Rheostat
- Remote Annunciator Panel
- Remote Control & Monitoring Panel
- Advanced SMS Messaging
- Control Panel Heater
- Battery Disconnect Switch
- Battery Heater
- Battery Charger 10/20 Amp
- Shunt Trip / Aux Contacts
- Spring Anti-vibration Isolators
- Automatic Transfer Panel (ATS)
- 5 Years / 2000 hours Limited Comprehensive Warranty
Codes & Standards
- Designed and manufactured in a facility certified to ISO9001 standards
- Designed and manufactured in a facility certified to ISO14001:2015 standards
- AKSA Power Generation provides single source responsibility for the generator set & accessories
- Prototype tested and production tested according to the UL test program
- Meets NFPA70, 99, 110, 37 Level 1 when equipped with the necessary accessories and installed per NFPA standards
product specifications:
| Specification | Value |
| Model Name | APD-ULJ65 |
| Engine Make | John Deere |
| Engine Model | 4045HF280 |
| Alternator Make | Stamford |
| Alternator Model | UCI224F |
| Control Panel Make & Model | DSE 7320 MK II |
| Frequency & Speed | 60 Hz, 1800 rpm |
| Enclosure Make & Model | AKSA AUL 41/42 |
| Standby Power | 65 kW |
| Power Factor | 0.8 |
| Voltage Options | 480/277V, 240/120V (1ph), 208/120V, 600/347V, 240/120V |
| Standby Current (480/277V) | 98 A |
| Engine Displacement & Cylinders | 4.5 L / 4 Cylinders |
| Engine Type | In-line, 4 Cycle |
| Engine Speed | 1800 rpm |
| Engine Prime Power | 67 kW |
| Engine Standby Power | 74 kW |
| Aspiration | Intercooled |
| Compression Ratio | 19.0 : 1 |
| Bore / Stroke | 4.17 in / 5.00 in |
| Governor Type | Mechanical |
| Engine Crankcase Vent System | Open |
| Ratio, Air : Fuel | 22 : 1 |
| Designed / Calibrated to Meet | EPA Tier 3 |
| Combustion System | Direct Injection |
| Max Fuel Inlet Temp. | 176 °F |
| Total Fuel Flow | 212 lb/hr |
| Fuel Consumption @ 100% Standby | 5.11 gal/h |
| Fuel Consumption @ 75% Standby | 3.94 gal/h |
| Fuel Consumption @ 50% Standby | 2.78 gal/h |
| Fuel Consumption @ 25% Standby | 1.54 gal/h |
| Electric System Voltage | 12V |
| Starter Rolling Current @ 32°F | 780 Amps |
| Battery Qty, Rating, CCA | 1 x 60 Ah |
| Radiator Cooling System Type | Closed Circuit |
| Coolant Capacity, Engine Only | 9 quart |
| Max Top Tank Temp | 221 °F |
| Exhaust Temperature | 1139 °F |
| Exhaust Gas Flow | 508 ft.3/min |
| Engine Air Flow | 191 ft.3/min |
| Air Filter Type | Dry Paper Element |
| Oil Pressure at Rated Speed | 345 kPa |
| Alternator Standards | BS EN 60034 |
| Alternator Control System | PMG |
| Alternator A.V.R. | MX341 |
| Voltage Regulation | ± 1 % |
| Insulation System | Class H |
| Protection | IP23 |
| Rated Power Factor | 0.8 |
| Maximum Overspeed | 2250 rev/min |
| Battery Charger Manufacturer / Model | ComAp / InteliCharger |
| Jacket Water Heater Manufacturer / Model | Hotstart / TPS101GT10-000 |
| Jacket Water Heater Power | 1000 W |
| Open Skid Length | 92.1 in |
| Open Skid Width (w/o lift hooks) | 43.3 in |
| Open Skid Height | 53.5 in |
| Open Skid Dry Weight | 2400 lbs |
| Level 1 Enclosure Length | 116.5 in |
| Level 1 Enclosure Width (w/o lift hooks) | 43.3 in |
| Level 1 Enclosure Height | 66.3 in |
| Level 1 Enclosure Dry Weight | 3600 lbs |
| Level 1 Sound Pressure @ 7 meters | 71 dB(A) |
| Level 2 Enclosure Length | 116.5 in |
| Level 2 Enclosure Width (w/o lift hooks) | 43.3 in |
| Level 2 Enclosure Height | 82 in |
| Level 2 Enclosure Dry Weight | 3900 lbs |
| Level 2 Sound Pressure @ 7 meters | 67 dB(A) |
| Fuel Tank 24hr Capacity | 130 gal |
| Fuel Tank 24hr Dimensions (L/W/H) | 130 / 43.3 / 12 in |
| Fuel Tank 24hr Weight | 1130 lbs |
| Fuel Tank 48hr Capacity | 260 gal |
| Fuel Tank 48hr Dimensions (L/W/H) | 130 / 43.3 / 20 in |
| Fuel Tank 48hr Weight | 1420 lbs |
| Fuel Tank 72hr Capacity | 390 gal |
| Fuel Tank 72hr Dimensions (L/W/H) | 130 / 43.3 / 28.5 in |
| Fuel Tank 72hr Weight | 1750 lbs |
| Warranty | 24 Months / 2000 hours Limited Standby Warranty |
product related documents:
| Peso | 3900 lbs |
|---|---|
| Dimensiones | 116.5 × 43.3 × 82 in |
Solo los usuarios registrados que hayan comprado este producto pueden hacer una valoración.





Valoraciones
No hay valoraciones aún.