The APD-NG800 is an 800 kW (480 kW LP) natural gas/LP dual-fuel standby generator set from AKSA Power Generation, built on a PSI (Doosan) 40L engine paired with a Stamford alternator and a DSE 7320 MK II control panel. Engineered for emergency stationary standby applications, it operates at 60 Hz / 1800 rpm and meets NFPA 110 Level 1 and EPA Stationary Standby requirements when equipped with the necessary accessories. The unit is available in three-phase configurations up to 480/277V and is backed by a heavy-duty steel enclosure with sound-attenuating foam, reflecting AKSA’s three-decade track record of reliable, compact industrial power generation. 

Key Features 

  • 800 kW Natural Gas / 480 kW LP Gas standby power output 
  • PSI (Doosan) 40L, 12-cylinder, turbocharged, dual-fuel engine 
  • Stamford alternator with PMG excitation and Class H insulation 
  • DSE 7320 MK II microprocessor-controlled, UL & NFPA 110 compatible panel 
  • 60 Hz operation at 1800 rpm with electronic governor 
  • UL2200 certified generator set 
  • Heavy-duty steel/aluminum enclosure with standard sound attenuation foam 
  • Engine jacket water heater, battery charger, and anti-vibration base frame included as standard 
  • Designed and manufactured in ISO 9001 and ISO 14001:2015 certified facilities 
  • 24 months / 2000 hours limited standby warranty (5 years / 2000 hours comprehensive warranty optional) 
Share:
Descripción
Additional Info
Reviews
Descripción

 

APD-NG800 product details and specifications:

General Characteristics 

  • Model Name: APD-NG800 
  • Engine Make: PSI (Doosan) 
  • Engine Model: 40L 
  • Alternator Make: Stamford 
  • Control Panel Make & Model: DSE 7320 MK II 
  • Frequency & Speed: 60Hz, 1800rpm 
  • Enclosure Make & Model: AKSA AUL 96A 

Genset Rating 

  • Engine: 40L 
  • Alternator options: HCI634H (Wnd-311), HCI634H (Wnd-312), HCI634G (Wnd-312), S6L1D-C (Wnd-311) 
  • Voltage options: 208/120V, 240/120V, 480/277V, 600/347V 
  • Power Factor: 0.8 
  • NG Standby Power: 800 kW 
  • NG Standby Current: 2776A (208/120V), 2406A (240/120V), 1203A (480/277V), 962A (600/347V) 
  • LP Gas Standby Power: 480 kW 
  • LP Gas Standby Current: 1665A (208/120V), 1443A (240/120V), 722A (480/277V), 577A (600/347V) 

Engine Data 

  • Manufacturer: PSI 
  • Model: NG40L 
  • Displacement & Cylinders: 39.2 L / 12 Cylinders 
  • Engine Type: V-type, 4 Cycle 
  • Engine Speed: 1800 rpm 
  • Engine Standby Power NG: 920 kWm 
  • Engine Standby Power LP: 584 kW 
  • Aspiration: Turbo Charge Air Cooled 
  • Compression Ratio: 10.5:1 
  • Bore / Stroke: 150 mm / 185 mm 
  • Governor Type: Electronic 

Fuel System 

  • Fuel Type: NG, LP Gas / Dual Fuel 
  • NG Supply Pipe Size: 3.0" NPTF 
  • Maximum EPR Rated Pressure: N/A 
  • Recommended Max Pressure: 2.7 kPa / 11.0 inH2O 
  • Recommended Min Pressure: 1.7 kPa / 7.0 inH2O 
  • Max LPG Vapor Pressure to EPR: 2.7 kPa / 11.0 inH2O 

Fuel Consumption 

  • Standby Power (100%): 10109 ft3/h (286 m3/h) NG / 83 gal/h (313 L/h) LP 
  • Standby Power (75%): 7503 ft3/h (212 m3/h) NG / 62 gal/h (236 L/h) LP 
  • Standby Power (50%): 5410 ft3/h (153 m3/h) NG / 43 gal/h (165 L/h) LP 

Electric System 

  • System Voltage (DC): 24V 
  • Battery Qty, Rating: 2 x 143Ah 

Cooling System 

  • Radiator Cooling System Type: Closed Circuit 
  • Coolant Capacity: 45.4 gal 
  • Cranking Temperature: 160°F 
  • Full Open Temperature: 198°F 

Exhaust System 

  • Type: Water Cooled Manifold 
  • Max Allowable Back Pressure: 13 kPa 
  • Turbine Outlet Temperature: 1238°F / 670°C 
  • Exhaust Gas Flow at Rated Power: 4920 cfm 

Air Intake System 

  • Combustion Air Required: 1591 cfm 
  • Max Intake Air Restriction (Clean Element): 1.3 kPa / 5.2 inH2O 
  • Air Filter Type: Dry Paper Element 

Lubrication System 

  • Oil Specifications: SAE 15W-40 Low Ash Gas Engine oil, API CD/CF or higher 
  • Oil Capacity, Min-Max: 127 - 154 Qts 
  • Oil Filter; Qty, Type: 2, Cartridge 
  • Min - Max Oil Pressure at Rated Speed: 47 - 57 psi (3.24 - 3.93 bar) 

Alternator Data 

  • Manufacturer: Stamford 
  • Standards: BS EN 60034 
  • Control System: PMG 
  • A.V.R.: MX321 
  • Voltage Regulation: ± 0.5% 
  • Insulation System: Class H 
  • Protection: IP23 
  • Rated Power Factor: 0.8 
  • Stator Winding: Double Layer Concentric 
  • Winding Pitch: Two Thirds 
  • Winding Leads: 6 
  • Telephone Interference: THF < 2% 
  • Waveform Distortion: No Load < 1.5% 
  • Maximum Overspeed: 2250 rev/min 

Controller Data 

  • Manufacturer: DSE 
  • Model: 7320 MK II 

Controller Features & Benefits 

  • Microprocessor controlled, UL & NFPA110 Compatible 
  • License free PC Software (Non-proprietary Software) 
  • IP65 rating offers increased resistance to water ingress 
  • Modules can be integrated to building management systems 
  • Real time clock provides accurate event log 
  • Four line back-lit LCD text display 
  • Five key menu navigation, two wire start/stop at Auto mode 
  • Front panel editing with PIN protection 
  • Support up to three remote display modules 
  • Configurable timers and alarms 
  • Multiple date and timer scheduler 
  • Integral PLC editor 
  • 'Protections disabled' feature 
  • Load switching (load shedding and dummy load outputs) 
  • Fully configurable via DSE Configuration Suite PC Software 
  • SCADA monitoring via DSE Configuration Suite PC Software 

Protection 

  • Gen. Voltage – under / over 
  • Gen. Freq. – under / over 
  • Engine Speed – under / over 
  • Engine Oil Pressure – low 
  • Engine Temp – low / high 
  • Battery Voltage – low / high 
  • Weak Battery 
  • Fail to Start / Stop 
  • Charge Alternator Fail 
  • Over Current & Load (kW/kVAr) 
  • Unbalanced Load 
  • Independent Earth Fault 
  • Reverse Power 
  • Loss of Speed Signal 

Instruments 

  • Gen. Voltage (L-L/L-N) 
  • Gen. Frequency 
  • Engine Speed 
  • Oil Pressure 
  • Water Temperature 
  • Battery Voltage 
  • Run Time 
  • Phase Sequence 
  • Power monitoring (kWh/kVAh/kVArh) 
  • Power (kWh/kVAh/kVArh) 
  • Power Factor 
  • Generator Current 
  • Generator Load (%) 
  • Earth Current 

Battery Charger & Electrical System Data 

  • Manufacturer: ComAp 
  • Model: InteliCharger 
  • Input Voltage: 85V ~ 264V AC 
  • Output Voltage / Current: 12V / 4A pk 

Jacket Water Heater Data 

  • Manufacturer: Hotstart 
  • Model: CKM1060260-000 
  • Input Voltage: 240V 
  • Power: 6000W 

Enclosure Features 

  • Heavy Duty Steel / Aluminum Structure 
  • E-Stop on Enclosure 
  • Control Panel Eliminated from Engine Vibrations 
  • Standard Sound Attenuation Foam 
  • Plastic Covered Corrosion Resistant Locks & Hinges 
  • Internally Mounted Exhaust System with Rain Cap 
  • Coolant Fill Cap 
  • Removable Base Frame Lifting Hooks 
  • Oil & Coolant Drain Ports 
  • Easy Access for Maintenance 

Standard Features & Accessories 

  • UL2200 Certification 
  • Heavy Duty Steel Base Frame 
  • PMG 
  • Engine Jacket Water Heater 
  • Battery and Battery Rack 
  • Battery Charger 
  • Anti Vibration Pads between Engine/Alternator & Base Frame 
  • Roof-mounted Critical Grade Silencer 
  • Residential Grade Silencer Set for Open Skid Sets 
  • Exhaust outlet rain cap and radiator fill cap 
  • Sound Absorb Foam Material for Enclosure 
  • Emergency Stop Button 
  • Oil Drain Valve 
  • Coolant Drain Valve 
  • Jacket Water Heater Isolation Valves 
  • Flex Fuel Lines 
  • Secondary Lock-off Valve on Baseframe 
  • Engine Manifold Cover 
  • Turbocharger Cover 
  • Protection Covers for Rotating Parts 
  • Exhaust Insulation Cover 
  • Enclosure DC Light 
  • Operations Manual 
  • 24 Months / 2000 hours Limited Standby Warranty 

Optional Accessories 

  • Main Line CB (3 / 4 Poles – 80% / 100% rated) 
  • Upsize Alternator 
  • Anti-condensation Heater 
  • Voltage Regulation ± 0.5% w/MX321 AVR 
  • Gas Regulator 
  • NG / LP Auto Changeover Control System 
  • Low Gas Pressure Alarm 
  • Low Coolant Level Alarm 
  • Oil Pan Heater 
  • Oil Temperature Display on Controller 
  • Manual Speed Adjust Rheostat 
  • Manual Voltage Adjust Rheostat 
  • Remote Annunciator Panel 
  • Remote Control & Monitoring Panel 
  • Advanced SMS Messaging 
  • Control Panel Heater 
  • Battery Disconnect Switch 
  • Battery Heater 
  • Battery Charger 10/20 Amp 
  • Shunt Trip / Aux Contacts 
  • Spring Anti-vibration Isolators 
  • Automatic Transfer Panel (ATS) 
  • 5 Years / 2000 hours Limited Comprehensive Warranty 

Codes & Standards 

  • Designed and manufactured in an ISO9001 certified facility 
  • Designed and manufactured in an ISO14001:2015 certified facility 
  • Single source responsibility for the generator set & accessories 
  • Prototype tested and production tested according to the UL test program 
  • Meets NFPA70, 99, 110, 37 Level 1 when equipped with necessary accessories and installed per NFPA standards (engine must be equipped with a fast start kit for NFPA110 Level 1 applications) 
  • EPA – Certified for Emergency Stationary Applications 

product specifications:

SpecificationValue
Model NameAPD-NG800
ManufacturerAKSA Power Generation
Engine MakePSI (Doosan)
Engine ModelNG40L
Alternator MakeStamford
Control Panel Make & ModelDSE 7320 MK II
Frequency & Speed60 Hz, 1800 rpm
Enclosure Make & ModelAKSA AUL 96A
NG Standby Power800 kW
NG Standby Current (208/120V)2776 A
LP Gas Standby Power480 kW
LP Gas Standby Current (208/120V)1665 A
Rated Power Factor0.8
Available Voltages208/120V, 240/120V, 480/277V, 600/347V
Displacement & Cylinders39.2 L / 12 Cylinders
Engine TypeV-type, 4 Cycle
Engine Speed1800 rpm
Engine Standby Power NG920 kWm
Engine Standby Power LP584 kW
AspirationTurbo Charge Air Cooled
Compression Ratio10.5:1
Bore / Stroke5.91 in / 7.28 in
Governor TypeElectronic
Fuel TypeNG, LP Gas / Dual Fuel
NG Supply Pipe Size3.0 in NPTF
Recommended Max Pressure2.7 kPa / 11.0 inH2O
Recommended Min Pressure1.7 kPa / 7.0 inH2O
Max LPG Vapor Pressure to EPR2.7 kPa / 11.0 inH2O
Fuel Consumption - Standby 100% (NG / LP)10109 ft3/h / 83 gal/h
Fuel Consumption - Standby 75% (NG / LP)7503 ft3/h / 62 gal/h
Fuel Consumption - Standby 50% (NG / LP)5410 ft3/h / 43 gal/h
System Voltage (DC)24V
Battery Qty, Rating2 x 143 Ah
Radiator Cooling System TypeClosed Circuit
Coolant Capacity45.4 gal
Cranking Temperature160 F
Full Open Temperature198 F
Exhaust System TypeWater Cooled Manifold
Max Allowable Back Pressure13 kPa
Turbine Outlet Temperature1238 F / 670 C
Exhaust Gas Flow at Rated Power4920 cfm
Combustion Air Required1591 cfm
Max Intake Air Restriction (Clean Element)1.3 kPa / 5.2 inH2O
Air Filter TypeDry Paper Element
Oil SpecificationsSAE 15W-40 Low Ash Gas Engine Oil, API CD/CF or higher
Oil Capacity, Min-Max127 - 154 Qts
Oil Filter; Qty, Type2, Cartridge
Min-Max Oil Pressure at Rated Speed47 - 57 psi
Alternator StandardsBS EN 60034
Alternator Control SystemPMG
A.V.R.MX321
Voltage Regulation+/- 0.5%
Insulation SystemClass H
Alternator ProtectionIP23
Stator WindingDouble Layer Concentric
Winding PitchTwo Thirds
Winding Leads6
Telephone InterferenceTHF < 2%
Waveform DistortionNo Load < 1.5%
Maximum Overspeed2250 rev/min
Controller ManufacturerDSE
Controller Model7320 MK II
Battery Charger ManufacturerComAp
Battery Charger ModelInteliCharger
Battery Charger Input Voltage85V - 264V AC
Battery Charger Output Voltage / Current12V / 4A pk
Jacket Water Heater ManufacturerHotstart
Jacket Water Heater ModelCKM1060260-000
Jacket Water Heater Input Voltage240V
Jacket Water Heater Power6000 W
CertificationUL2200
EPA CertificationCertified for Emergency Stationary Applications
NFPA ComplianceNFPA 70, 99, 110 (Level 1), 37
Warranty (Standard)24 Months / 2000 Hours Limited Standby
Warranty (Optional)5 Years / 2000 Hours Limited Comprehensive

 

product related documents:

APD-NG800.pdf

Additional Info
Peso22300 lbs
Dimensiones256 × 91 × 99 in
Reviews

Valoraciones

No hay valoraciones aún.

Solo los usuarios registrados que hayan comprado este producto pueden hacer una valoración.

Item añadido al carrito View Cart Checkout
Item added to wishlist View Wishlist
Item removed from wishlist