Aksa Gas Generator APD-NG800 (800kW)



Aksa Gas Generator APD-NG800 (800kW)
Call for Price
The APD-NG800 is an 800 kW (480 kW LP) natural gas/LP dual-fuel standby generator set from AKSA Power Generation, built on a PSI (Doosan) 40L engine paired with a Stamford alternator and a DSE 7320 MK II control panel. Engineered for emergency stationary standby applications, it operates at 60 Hz / 1800 rpm and meets NFPA 110 Level 1 and EPA Stationary Standby requirements when equipped with the necessary accessories. The unit is available in three-phase configurations up to 480/277V and is backed by a heavy-duty steel enclosure with sound-attenuating foam, reflecting AKSA’s three-decade track record of reliable, compact industrial power generation.
Key Features
- 800 kW Natural Gas / 480 kW LP Gas standby power output
- PSI (Doosan) 40L, 12-cylinder, turbocharged, dual-fuel engine
- Stamford alternator with PMG excitation and Class H insulation
- DSE 7320 MK II microprocessor-controlled, UL & NFPA 110 compatible panel
- 60 Hz operation at 1800 rpm with electronic governor
- UL2200 certified generator set
- Heavy-duty steel/aluminum enclosure with standard sound attenuation foam
- Engine jacket water heater, battery charger, and anti-vibration base frame included as standard
- Designed and manufactured in ISO 9001 and ISO 14001:2015 certified facilities
- 24 months / 2000 hours limited standby warranty (5 years / 2000 hours comprehensive warranty optional)
APD-NG800 product details and specifications:
General Characteristics
- Model Name: APD-NG800
- Engine Make: PSI (Doosan)
- Engine Model: 40L
- Alternator Make: Stamford
- Control Panel Make & Model: DSE 7320 MK II
- Frequency & Speed: 60Hz, 1800rpm
- Enclosure Make & Model: AKSA AUL 96A
Genset Rating
- Engine: 40L
- Alternator options: HCI634H (Wnd-311), HCI634H (Wnd-312), HCI634G (Wnd-312), S6L1D-C (Wnd-311)
- Voltage options: 208/120V, 240/120V, 480/277V, 600/347V
- Power Factor: 0.8
- NG Standby Power: 800 kW
- NG Standby Current: 2776A (208/120V), 2406A (240/120V), 1203A (480/277V), 962A (600/347V)
- LP Gas Standby Power: 480 kW
- LP Gas Standby Current: 1665A (208/120V), 1443A (240/120V), 722A (480/277V), 577A (600/347V)
Engine Data
- Manufacturer: PSI
- Model: NG40L
- Displacement & Cylinders: 39.2 L / 12 Cylinders
- Engine Type: V-type, 4 Cycle
- Engine Speed: 1800 rpm
- Engine Standby Power NG: 920 kWm
- Engine Standby Power LP: 584 kW
- Aspiration: Turbo Charge Air Cooled
- Compression Ratio: 10.5:1
- Bore / Stroke: 150 mm / 185 mm
- Governor Type: Electronic
Fuel System
- Fuel Type: NG, LP Gas / Dual Fuel
- NG Supply Pipe Size: 3.0" NPTF
- Maximum EPR Rated Pressure: N/A
- Recommended Max Pressure: 2.7 kPa / 11.0 inH2O
- Recommended Min Pressure: 1.7 kPa / 7.0 inH2O
- Max LPG Vapor Pressure to EPR: 2.7 kPa / 11.0 inH2O
Fuel Consumption
- Standby Power (100%): 10109 ft3/h (286 m3/h) NG / 83 gal/h (313 L/h) LP
- Standby Power (75%): 7503 ft3/h (212 m3/h) NG / 62 gal/h (236 L/h) LP
- Standby Power (50%): 5410 ft3/h (153 m3/h) NG / 43 gal/h (165 L/h) LP
Electric System
- System Voltage (DC): 24V
- Battery Qty, Rating: 2 x 143Ah
Cooling System
- Radiator Cooling System Type: Closed Circuit
- Coolant Capacity: 45.4 gal
- Cranking Temperature: 160°F
- Full Open Temperature: 198°F
Exhaust System
- Type: Water Cooled Manifold
- Max Allowable Back Pressure: 13 kPa
- Turbine Outlet Temperature: 1238°F / 670°C
- Exhaust Gas Flow at Rated Power: 4920 cfm
Air Intake System
- Combustion Air Required: 1591 cfm
- Max Intake Air Restriction (Clean Element): 1.3 kPa / 5.2 inH2O
- Air Filter Type: Dry Paper Element
Lubrication System
- Oil Specifications: SAE 15W-40 Low Ash Gas Engine oil, API CD/CF or higher
- Oil Capacity, Min-Max: 127 - 154 Qts
- Oil Filter; Qty, Type: 2, Cartridge
- Min - Max Oil Pressure at Rated Speed: 47 - 57 psi (3.24 - 3.93 bar)
Alternator Data
- Manufacturer: Stamford
- Standards: BS EN 60034
- Control System: PMG
- A.V.R.: MX321
- Voltage Regulation: ± 0.5%
- Insulation System: Class H
- Protection: IP23
- Rated Power Factor: 0.8
- Stator Winding: Double Layer Concentric
- Winding Pitch: Two Thirds
- Winding Leads: 6
- Telephone Interference: THF < 2%
- Waveform Distortion: No Load < 1.5%
- Maximum Overspeed: 2250 rev/min
Controller Data
- Manufacturer: DSE
- Model: 7320 MK II
Controller Features & Benefits
- Microprocessor controlled, UL & NFPA110 Compatible
- License free PC Software (Non-proprietary Software)
- IP65 rating offers increased resistance to water ingress
- Modules can be integrated to building management systems
- Real time clock provides accurate event log
- Four line back-lit LCD text display
- Five key menu navigation, two wire start/stop at Auto mode
- Front panel editing with PIN protection
- Support up to three remote display modules
- Configurable timers and alarms
- Multiple date and timer scheduler
- Integral PLC editor
- 'Protections disabled' feature
- Load switching (load shedding and dummy load outputs)
- Fully configurable via DSE Configuration Suite PC Software
- SCADA monitoring via DSE Configuration Suite PC Software
Protection
- Gen. Voltage – under / over
- Gen. Freq. – under / over
- Engine Speed – under / over
- Engine Oil Pressure – low
- Engine Temp – low / high
- Battery Voltage – low / high
- Weak Battery
- Fail to Start / Stop
- Charge Alternator Fail
- Over Current & Load (kW/kVAr)
- Unbalanced Load
- Independent Earth Fault
- Reverse Power
- Loss of Speed Signal
Instruments
- Gen. Voltage (L-L/L-N)
- Gen. Frequency
- Engine Speed
- Oil Pressure
- Water Temperature
- Battery Voltage
- Run Time
- Phase Sequence
- Power monitoring (kWh/kVAh/kVArh)
- Power (kWh/kVAh/kVArh)
- Power Factor
- Generator Current
- Generator Load (%)
- Earth Current
Battery Charger & Electrical System Data
- Manufacturer: ComAp
- Model: InteliCharger
- Input Voltage: 85V ~ 264V AC
- Output Voltage / Current: 12V / 4A pk
Jacket Water Heater Data
- Manufacturer: Hotstart
- Model: CKM1060260-000
- Input Voltage: 240V
- Power: 6000W
Enclosure Features
- Heavy Duty Steel / Aluminum Structure
- E-Stop on Enclosure
- Control Panel Eliminated from Engine Vibrations
- Standard Sound Attenuation Foam
- Plastic Covered Corrosion Resistant Locks & Hinges
- Internally Mounted Exhaust System with Rain Cap
- Coolant Fill Cap
- Removable Base Frame Lifting Hooks
- Oil & Coolant Drain Ports
- Easy Access for Maintenance
Standard Features & Accessories
- UL2200 Certification
- Heavy Duty Steel Base Frame
- PMG
- Engine Jacket Water Heater
- Battery and Battery Rack
- Battery Charger
- Anti Vibration Pads between Engine/Alternator & Base Frame
- Roof-mounted Critical Grade Silencer
- Residential Grade Silencer Set for Open Skid Sets
- Exhaust outlet rain cap and radiator fill cap
- Sound Absorb Foam Material for Enclosure
- Emergency Stop Button
- Oil Drain Valve
- Coolant Drain Valve
- Jacket Water Heater Isolation Valves
- Flex Fuel Lines
- Secondary Lock-off Valve on Baseframe
- Engine Manifold Cover
- Turbocharger Cover
- Protection Covers for Rotating Parts
- Exhaust Insulation Cover
- Enclosure DC Light
- Operations Manual
- 24 Months / 2000 hours Limited Standby Warranty
Optional Accessories
- Main Line CB (3 / 4 Poles – 80% / 100% rated)
- Upsize Alternator
- Anti-condensation Heater
- Voltage Regulation ± 0.5% w/MX321 AVR
- Gas Regulator
- NG / LP Auto Changeover Control System
- Low Gas Pressure Alarm
- Low Coolant Level Alarm
- Oil Pan Heater
- Oil Temperature Display on Controller
- Manual Speed Adjust Rheostat
- Manual Voltage Adjust Rheostat
- Remote Annunciator Panel
- Remote Control & Monitoring Panel
- Advanced SMS Messaging
- Control Panel Heater
- Battery Disconnect Switch
- Battery Heater
- Battery Charger 10/20 Amp
- Shunt Trip / Aux Contacts
- Spring Anti-vibration Isolators
- Automatic Transfer Panel (ATS)
- 5 Years / 2000 hours Limited Comprehensive Warranty
Codes & Standards
- Designed and manufactured in an ISO9001 certified facility
- Designed and manufactured in an ISO14001:2015 certified facility
- Single source responsibility for the generator set & accessories
- Prototype tested and production tested according to the UL test program
- Meets NFPA70, 99, 110, 37 Level 1 when equipped with necessary accessories and installed per NFPA standards (engine must be equipped with a fast start kit for NFPA110 Level 1 applications)
- EPA – Certified for Emergency Stationary Applications
product specifications:
| Specification | Value |
| Model Name | APD-NG800 |
| Manufacturer | AKSA Power Generation |
| Engine Make | PSI (Doosan) |
| Engine Model | NG40L |
| Alternator Make | Stamford |
| Control Panel Make & Model | DSE 7320 MK II |
| Frequency & Speed | 60 Hz, 1800 rpm |
| Enclosure Make & Model | AKSA AUL 96A |
| NG Standby Power | 800 kW |
| NG Standby Current (208/120V) | 2776 A |
| LP Gas Standby Power | 480 kW |
| LP Gas Standby Current (208/120V) | 1665 A |
| Rated Power Factor | 0.8 |
| Available Voltages | 208/120V, 240/120V, 480/277V, 600/347V |
| Displacement & Cylinders | 39.2 L / 12 Cylinders |
| Engine Type | V-type, 4 Cycle |
| Engine Speed | 1800 rpm |
| Engine Standby Power NG | 920 kWm |
| Engine Standby Power LP | 584 kW |
| Aspiration | Turbo Charge Air Cooled |
| Compression Ratio | 10.5:1 |
| Bore / Stroke | 5.91 in / 7.28 in |
| Governor Type | Electronic |
| Fuel Type | NG, LP Gas / Dual Fuel |
| NG Supply Pipe Size | 3.0 in NPTF |
| Recommended Max Pressure | 2.7 kPa / 11.0 inH2O |
| Recommended Min Pressure | 1.7 kPa / 7.0 inH2O |
| Max LPG Vapor Pressure to EPR | 2.7 kPa / 11.0 inH2O |
| Fuel Consumption - Standby 100% (NG / LP) | 10109 ft3/h / 83 gal/h |
| Fuel Consumption - Standby 75% (NG / LP) | 7503 ft3/h / 62 gal/h |
| Fuel Consumption - Standby 50% (NG / LP) | 5410 ft3/h / 43 gal/h |
| System Voltage (DC) | 24V |
| Battery Qty, Rating | 2 x 143 Ah |
| Radiator Cooling System Type | Closed Circuit |
| Coolant Capacity | 45.4 gal |
| Cranking Temperature | 160 F |
| Full Open Temperature | 198 F |
| Exhaust System Type | Water Cooled Manifold |
| Max Allowable Back Pressure | 13 kPa |
| Turbine Outlet Temperature | 1238 F / 670 C |
| Exhaust Gas Flow at Rated Power | 4920 cfm |
| Combustion Air Required | 1591 cfm |
| Max Intake Air Restriction (Clean Element) | 1.3 kPa / 5.2 inH2O |
| Air Filter Type | Dry Paper Element |
| Oil Specifications | SAE 15W-40 Low Ash Gas Engine Oil, API CD/CF or higher |
| Oil Capacity, Min-Max | 127 - 154 Qts |
| Oil Filter; Qty, Type | 2, Cartridge |
| Min-Max Oil Pressure at Rated Speed | 47 - 57 psi |
| Alternator Standards | BS EN 60034 |
| Alternator Control System | PMG |
| A.V.R. | MX321 |
| Voltage Regulation | +/- 0.5% |
| Insulation System | Class H |
| Alternator Protection | IP23 |
| Stator Winding | Double Layer Concentric |
| Winding Pitch | Two Thirds |
| Winding Leads | 6 |
| Telephone Interference | THF < 2% |
| Waveform Distortion | No Load < 1.5% |
| Maximum Overspeed | 2250 rev/min |
| Controller Manufacturer | DSE |
| Controller Model | 7320 MK II |
| Battery Charger Manufacturer | ComAp |
| Battery Charger Model | InteliCharger |
| Battery Charger Input Voltage | 85V - 264V AC |
| Battery Charger Output Voltage / Current | 12V / 4A pk |
| Jacket Water Heater Manufacturer | Hotstart |
| Jacket Water Heater Model | CKM1060260-000 |
| Jacket Water Heater Input Voltage | 240V |
| Jacket Water Heater Power | 6000 W |
| Certification | UL2200 |
| EPA Certification | Certified for Emergency Stationary Applications |
| NFPA Compliance | NFPA 70, 99, 110 (Level 1), 37 |
| Warranty (Standard) | 24 Months / 2000 Hours Limited Standby |
| Warranty (Optional) | 5 Years / 2000 Hours Limited Comprehensive |
product related documents:
| Peso | 22300 lbs |
|---|---|
| Dimensiones | 256 × 91 × 99 in |
Solo los usuarios registrados que hayan comprado este producto pueden hacer una valoración.





Valoraciones
No hay valoraciones aún.