The APD-NG800 is an 800 kW (480 kW LP) natural gas/LP dual-fuel standby generator set from AKSA Power Generation, built on a PSI (Doosan) 40L engine paired with a Stamford alternator and a DSE 7320 MK II control panel. Engineered for emergency stationary standby applications, it operates at 60 Hz / 1800 rpm and meets NFPA 110 Level 1 and EPA Stationary Standby requirements when equipped with the necessary accessories. The unit is available in three-phase configurations up to 480/277V and is backed by a heavy-duty steel enclosure with sound-attenuating foam, reflecting AKSA’s three-decade track record of reliable, compact industrial power generation. 

Key Features 

  • 800 kW Natural Gas / 480 kW LP Gas standby power output 
  • PSI (Doosan) 40L, 12-cylinder, turbocharged, dual-fuel engine 
  • Stamford alternator with PMG excitation and Class H insulation 
  • DSE 7320 MK II microprocessor-controlled, UL & NFPA 110 compatible panel 
  • 60 Hz operation at 1800 rpm with electronic governor 
  • UL2200 certified generator set 
  • Heavy-duty steel/aluminum enclosure with standard sound attenuation foam 
  • Engine jacket water heater, battery charger, and anti-vibration base frame included as standard 
  • Designed and manufactured in ISO 9001 and ISO 14001:2015 certified facilities 
  • 24 months / 2000 hours limited standby warranty (5 years / 2000 hours comprehensive warranty optional) 
Share:
Description
Additional Info
Reviews
Description

 

APD-NG800 product details and specifications:

General Characteristics 

  • Model Name: APD-NG800 
  • Engine Make: PSI (Doosan) 
  • Engine Model: 40L 
  • Alternator Make: Stamford 
  • Control Panel Make & Model: DSE 7320 MK II 
  • Frequency & Speed: 60Hz, 1800rpm 
  • Enclosure Make & Model: AKSA AUL 96A 

Genset Rating 

  • Engine: 40L 
  • Alternator options: HCI634H (Wnd-311), HCI634H (Wnd-312), HCI634G (Wnd-312), S6L1D-C (Wnd-311) 
  • Voltage options: 208/120V, 240/120V, 480/277V, 600/347V 
  • Power Factor: 0.8 
  • NG Standby Power: 800 kW 
  • NG Standby Current: 2776A (208/120V), 2406A (240/120V), 1203A (480/277V), 962A (600/347V) 
  • LP Gas Standby Power: 480 kW 
  • LP Gas Standby Current: 1665A (208/120V), 1443A (240/120V), 722A (480/277V), 577A (600/347V) 

Engine Data 

  • Manufacturer: PSI 
  • Model: NG40L 
  • Displacement & Cylinders: 39.2 L / 12 Cylinders 
  • Engine Type: V-type, 4 Cycle 
  • Engine Speed: 1800 rpm 
  • Engine Standby Power NG: 920 kWm 
  • Engine Standby Power LP: 584 kW 
  • Aspiration: Turbo Charge Air Cooled 
  • Compression Ratio: 10.5:1 
  • Bore / Stroke: 150 mm / 185 mm 
  • Governor Type: Electronic 

Fuel System 

  • Fuel Type: NG, LP Gas / Dual Fuel 
  • NG Supply Pipe Size: 3.0" NPTF 
  • Maximum EPR Rated Pressure: N/A 
  • Recommended Max Pressure: 2.7 kPa / 11.0 inH2O 
  • Recommended Min Pressure: 1.7 kPa / 7.0 inH2O 
  • Max LPG Vapor Pressure to EPR: 2.7 kPa / 11.0 inH2O 

Fuel Consumption 

  • Standby Power (100%): 10109 ft3/h (286 m3/h) NG / 83 gal/h (313 L/h) LP 
  • Standby Power (75%): 7503 ft3/h (212 m3/h) NG / 62 gal/h (236 L/h) LP 
  • Standby Power (50%): 5410 ft3/h (153 m3/h) NG / 43 gal/h (165 L/h) LP 

Electric System 

  • System Voltage (DC): 24V 
  • Battery Qty, Rating: 2 x 143Ah 

Cooling System 

  • Radiator Cooling System Type: Closed Circuit 
  • Coolant Capacity: 45.4 gal 
  • Cranking Temperature: 160°F 
  • Full Open Temperature: 198°F 

Exhaust System 

  • Type: Water Cooled Manifold 
  • Max Allowable Back Pressure: 13 kPa 
  • Turbine Outlet Temperature: 1238°F / 670°C 
  • Exhaust Gas Flow at Rated Power: 4920 cfm 

Air Intake System 

  • Combustion Air Required: 1591 cfm 
  • Max Intake Air Restriction (Clean Element): 1.3 kPa / 5.2 inH2O 
  • Air Filter Type: Dry Paper Element 

Lubrication System 

  • Oil Specifications: SAE 15W-40 Low Ash Gas Engine oil, API CD/CF or higher 
  • Oil Capacity, Min-Max: 127 - 154 Qts 
  • Oil Filter; Qty, Type: 2, Cartridge 
  • Min - Max Oil Pressure at Rated Speed: 47 - 57 psi (3.24 - 3.93 bar) 

Alternator Data 

  • Manufacturer: Stamford 
  • Standards: BS EN 60034 
  • Control System: PMG 
  • A.V.R.: MX321 
  • Voltage Regulation: ± 0.5% 
  • Insulation System: Class H 
  • Protection: IP23 
  • Rated Power Factor: 0.8 
  • Stator Winding: Double Layer Concentric 
  • Winding Pitch: Two Thirds 
  • Winding Leads: 6 
  • Telephone Interference: THF < 2% 
  • Waveform Distortion: No Load < 1.5% 
  • Maximum Overspeed: 2250 rev/min 

Controller Data 

  • Manufacturer: DSE 
  • Model: 7320 MK II 

Controller Features & Benefits 

  • Microprocessor controlled, UL & NFPA110 Compatible 
  • License free PC Software (Non-proprietary Software) 
  • IP65 rating offers increased resistance to water ingress 
  • Modules can be integrated to building management systems 
  • Real time clock provides accurate event log 
  • Four line back-lit LCD text display 
  • Five key menu navigation, two wire start/stop at Auto mode 
  • Front panel editing with PIN protection 
  • Support up to three remote display modules 
  • Configurable timers and alarms 
  • Multiple date and timer scheduler 
  • Integral PLC editor 
  • 'Protections disabled' feature 
  • Load switching (load shedding and dummy load outputs) 
  • Fully configurable via DSE Configuration Suite PC Software 
  • SCADA monitoring via DSE Configuration Suite PC Software 

Protection 

  • Gen. Voltage – under / over 
  • Gen. Freq. – under / over 
  • Engine Speed – under / over 
  • Engine Oil Pressure – low 
  • Engine Temp – low / high 
  • Battery Voltage – low / high 
  • Weak Battery 
  • Fail to Start / Stop 
  • Charge Alternator Fail 
  • Over Current & Load (kW/kVAr) 
  • Unbalanced Load 
  • Independent Earth Fault 
  • Reverse Power 
  • Loss of Speed Signal 

Instruments 

  • Gen. Voltage (L-L/L-N) 
  • Gen. Frequency 
  • Engine Speed 
  • Oil Pressure 
  • Water Temperature 
  • Battery Voltage 
  • Run Time 
  • Phase Sequence 
  • Power monitoring (kWh/kVAh/kVArh) 
  • Power (kWh/kVAh/kVArh) 
  • Power Factor 
  • Generator Current 
  • Generator Load (%) 
  • Earth Current 

Battery Charger & Electrical System Data 

  • Manufacturer: ComAp 
  • Model: InteliCharger 
  • Input Voltage: 85V ~ 264V AC 
  • Output Voltage / Current: 12V / 4A pk 

Jacket Water Heater Data 

  • Manufacturer: Hotstart 
  • Model: CKM1060260-000 
  • Input Voltage: 240V 
  • Power: 6000W 

Enclosure Features 

  • Heavy Duty Steel / Aluminum Structure 
  • E-Stop on Enclosure 
  • Control Panel Eliminated from Engine Vibrations 
  • Standard Sound Attenuation Foam 
  • Plastic Covered Corrosion Resistant Locks & Hinges 
  • Internally Mounted Exhaust System with Rain Cap 
  • Coolant Fill Cap 
  • Removable Base Frame Lifting Hooks 
  • Oil & Coolant Drain Ports 
  • Easy Access for Maintenance 

Standard Features & Accessories 

  • UL2200 Certification 
  • Heavy Duty Steel Base Frame 
  • PMG 
  • Engine Jacket Water Heater 
  • Battery and Battery Rack 
  • Battery Charger 
  • Anti Vibration Pads between Engine/Alternator & Base Frame 
  • Roof-mounted Critical Grade Silencer 
  • Residential Grade Silencer Set for Open Skid Sets 
  • Exhaust outlet rain cap and radiator fill cap 
  • Sound Absorb Foam Material for Enclosure 
  • Emergency Stop Button 
  • Oil Drain Valve 
  • Coolant Drain Valve 
  • Jacket Water Heater Isolation Valves 
  • Flex Fuel Lines 
  • Secondary Lock-off Valve on Baseframe 
  • Engine Manifold Cover 
  • Turbocharger Cover 
  • Protection Covers for Rotating Parts 
  • Exhaust Insulation Cover 
  • Enclosure DC Light 
  • Operations Manual 
  • 24 Months / 2000 hours Limited Standby Warranty 

Optional Accessories 

  • Main Line CB (3 / 4 Poles – 80% / 100% rated) 
  • Upsize Alternator 
  • Anti-condensation Heater 
  • Voltage Regulation ± 0.5% w/MX321 AVR 
  • Gas Regulator 
  • NG / LP Auto Changeover Control System 
  • Low Gas Pressure Alarm 
  • Low Coolant Level Alarm 
  • Oil Pan Heater 
  • Oil Temperature Display on Controller 
  • Manual Speed Adjust Rheostat 
  • Manual Voltage Adjust Rheostat 
  • Remote Annunciator Panel 
  • Remote Control & Monitoring Panel 
  • Advanced SMS Messaging 
  • Control Panel Heater 
  • Battery Disconnect Switch 
  • Battery Heater 
  • Battery Charger 10/20 Amp 
  • Shunt Trip / Aux Contacts 
  • Spring Anti-vibration Isolators 
  • Automatic Transfer Panel (ATS) 
  • 5 Years / 2000 hours Limited Comprehensive Warranty 

Codes & Standards 

  • Designed and manufactured in an ISO9001 certified facility 
  • Designed and manufactured in an ISO14001:2015 certified facility 
  • Single source responsibility for the generator set & accessories 
  • Prototype tested and production tested according to the UL test program 
  • Meets NFPA70, 99, 110, 37 Level 1 when equipped with necessary accessories and installed per NFPA standards (engine must be equipped with a fast start kit for NFPA110 Level 1 applications) 
  • EPA – Certified for Emergency Stationary Applications 

product specifications:

SpecificationValue
Model NameAPD-NG800
ManufacturerAKSA Power Generation
Engine MakePSI (Doosan)
Engine ModelNG40L
Alternator MakeStamford
Control Panel Make & ModelDSE 7320 MK II
Frequency & Speed60 Hz, 1800 rpm
Enclosure Make & ModelAKSA AUL 96A
NG Standby Power800 kW
NG Standby Current (208/120V)2776 A
LP Gas Standby Power480 kW
LP Gas Standby Current (208/120V)1665 A
Rated Power Factor0.8
Available Voltages208/120V, 240/120V, 480/277V, 600/347V
Displacement & Cylinders39.2 L / 12 Cylinders
Engine TypeV-type, 4 Cycle
Engine Speed1800 rpm
Engine Standby Power NG920 kWm
Engine Standby Power LP584 kW
AspirationTurbo Charge Air Cooled
Compression Ratio10.5:1
Bore / Stroke5.91 in / 7.28 in
Governor TypeElectronic
Fuel TypeNG, LP Gas / Dual Fuel
NG Supply Pipe Size3.0 in NPTF
Recommended Max Pressure2.7 kPa / 11.0 inH2O
Recommended Min Pressure1.7 kPa / 7.0 inH2O
Max LPG Vapor Pressure to EPR2.7 kPa / 11.0 inH2O
Fuel Consumption - Standby 100% (NG / LP)10109 ft3/h / 83 gal/h
Fuel Consumption - Standby 75% (NG / LP)7503 ft3/h / 62 gal/h
Fuel Consumption - Standby 50% (NG / LP)5410 ft3/h / 43 gal/h
System Voltage (DC)24V
Battery Qty, Rating2 x 143 Ah
Radiator Cooling System TypeClosed Circuit
Coolant Capacity45.4 gal
Cranking Temperature160 F
Full Open Temperature198 F
Exhaust System TypeWater Cooled Manifold
Max Allowable Back Pressure13 kPa
Turbine Outlet Temperature1238 F / 670 C
Exhaust Gas Flow at Rated Power4920 cfm
Combustion Air Required1591 cfm
Max Intake Air Restriction (Clean Element)1.3 kPa / 5.2 inH2O
Air Filter TypeDry Paper Element
Oil SpecificationsSAE 15W-40 Low Ash Gas Engine Oil, API CD/CF or higher
Oil Capacity, Min-Max127 - 154 Qts
Oil Filter; Qty, Type2, Cartridge
Min-Max Oil Pressure at Rated Speed47 - 57 psi
Alternator StandardsBS EN 60034
Alternator Control SystemPMG
A.V.R.MX321
Voltage Regulation+/- 0.5%
Insulation SystemClass H
Alternator ProtectionIP23
Stator WindingDouble Layer Concentric
Winding PitchTwo Thirds
Winding Leads6
Telephone InterferenceTHF < 2%
Waveform DistortionNo Load < 1.5%
Maximum Overspeed2250 rev/min
Controller ManufacturerDSE
Controller Model7320 MK II
Battery Charger ManufacturerComAp
Battery Charger ModelInteliCharger
Battery Charger Input Voltage85V - 264V AC
Battery Charger Output Voltage / Current12V / 4A pk
Jacket Water Heater ManufacturerHotstart
Jacket Water Heater ModelCKM1060260-000
Jacket Water Heater Input Voltage240V
Jacket Water Heater Power6000 W
CertificationUL2200
EPA CertificationCertified for Emergency Stationary Applications
NFPA ComplianceNFPA 70, 99, 110 (Level 1), 37
Warranty (Standard)24 Months / 2000 Hours Limited Standby
Warranty (Optional)5 Years / 2000 Hours Limited Comprehensive

 

product related documents:

APD-NG800.pdf

Additional Info
Weight22300 lbs
Dimensions256 × 91 × 99 in
Reviews

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Item added to cart View Cart Checkout
Item added to wishlist View Wishlist
Item removed from wishlist