Aksa APD-ULV550 (550kW)

Share this product!

Aksa APD-ULV550 (550kW)

Call for Price

SKU: APD-ULV550

The AKSA Power Generation APD-ULV550 is a UL2200-listed, 550 kW standby diesel generator set built around a Volvo Penta TAD1642GE engine and a Stamford alternator. Designed for emergency and standby power applications, the unit pairs a DSE 7320 MK II control panel with a heavy-duty steel and aluminum enclosure to deliver reliable, code-compliant backup power. Manufactured in facilities certified to ISO9001 and ISO14001:2015, and tested to UL and NFPA110 Level 1 standards, the APD-ULV550 is engineered for demanding commercial and industrial standby power needs. 

Key Features 

  • 550 kW standby power at 480/277V, 0.8 power factor 
  • Volvo Penta TAD1642GE diesel engine, 60Hz / 1800 rpm 
  • Stamford HCI534E alternator with Class H insulation and IP23 protection 
  • DSE 7320 MK II microprocessor-controlled panel, UL & NFPA110 compatible 
  • UL2200 certified for emergency stationary applications 
  • Meets NFPA70, 99, 110, and 37 Level 1 standards 
  • Heavy-duty steel/aluminum enclosure with sound attenuation foam 
  • Engine jacket water heater and battery charger included standard 
  • 24 Months / 2,000 hours limited standby warranty 
  • ISO9001 and ISO14001:2015 certified manufacturing facilities 
Share:
Descripción
Additional Info
Reviews
Descripción

 

APD-ULV550 product details and specifications:

General Characteristics 

  • Model Name: APD-ULV550 
  • Engine Make: Volvo 
  • Engine Model: TAD1642GE 
  • Alternator Make: Stamford 
  • Control Panel Make & Model: DSE 7320 MK II 
  • Frequency & Speed: 60Hz, 1800 rpm 
  • Enclosure Make & Model: AKSA AUL 71/72 

Genset Rating (TAD1642GE) 

  • HCI534E (Wnd-311): 480/277V, 550kW standby, 0.8 PF, 827A standby current 
  • HCI534E (Wnd-311): 240/120V, 545kW standby, 0.8 PF, 1639A standby current 
  • HCI534E (Wnd-311): 208/120V, 545kW standby, 0.8 PF, 1891A standby current 
  • HCI534E (Wnd-17): 600/347V, 550kW standby, 0.8 PF, 662A standby current 

Engine Data 

  • Manufacturer: Volvo Penta 
  • Model: TAD1642GE 
  • Displacement & Cylinders: 16.12 L / 6 Cylinders 
  • Engine Speed: 1800 rpm 
  • Engine Standby Power: 585 kW 
  • Engine Prime Power: 532 kW 
  • Aspiration: Turbocharged 
  • Compression Ratio: 16.5 : 1 
  • Bore / Stroke: 144 mm / 165 mm 
  • Effective Mean Pressure, Standby Power: 2.5 Mpa 
  • Max Combustion Pressure, Standby Power: 18.9 Mpa 
  • Total Mass Moment of Inertia: 4.20 kgm² 
  • Friction Power: 53 kW 
  • Wet Weight – Engine Only: 3417 lb 
  • Wet Weight – GenPac: 4453 lb 
  • Engine Crankcase Vent System: Open 

Fuel System 

  • Injection Pump Type: Delphi / E1 
  • System Supply Flow: 53 g/h 
  • System Return Flow: 6.6 g/h 
  • Max Allowable Inlet Fuel Temp: 140 °F 

Fuel Consumption 

  • Standby Power (100%): 38.5 gal/h 
  • Standby Power (75%): 27.8 gal/h 
  • Standby Power (50%): 18.5 gal/h 
  • Standby Power (25%): 10.0 gal/h 

Electric System 

  • Voltage & Type: 24V, Insulated from Earth 
  • Alternator Make / Output: Bosch / 80A 
  • Battery Qty, Rating: 2 x 120Ah 

Cooling System 

  • Radiator Cooling System Type: Closed Circuit 
  • Fan Power Consumption: 19 kW 
  • Coolant Capacity: 15.85 gal 
  • Max Top Tank Temperature: 217 °F 
  • Thermostat, Start – Fully Open: 187–205 °F 

Exhaust System 

  • Exhaust Gas Temp: 954 °C 
  • Max Allowable Back Pressure: 10 kPa 
  • Exhaust Gas Flow: 117.6 m³/min 

Air Intake System 

  • Air Consumption: 46.6 m³/min 
  • Max Intake Air Restriction: 5 kPa 
  • Air Filter Type: Single Stage Paper Cartridge 

Lubrication System 

  • Total System Capacity: 12.7 gal 
  • Sump Capacity Max / Min: 11.1 gal / 8.5 gal 
  • Max Oil Temp: 266 °C 
  • Oil Pressure at Rated Speed: 44–94 psi 
  • Oil Consumption: 0.032 gal/h 

Alternator Data 

  • Manufacturer: Stamford 
  • Standards: BS EN 60034 
  • Control System: PMG 
  • A.V.R.: MX341 
  • Voltage Regulation: ± 1 % 
  • Insulation System: Class H 
  • Protection: IP23 
  • Rated Power Factor: 0.8 
  • Stator Winding: Double Layer Concentric 
  • Winding Pitch: Two Thirds 
  • Winding Leads: 12 
  • Telephone Interference: THF < 2 % 
  • Waveform Distortion: No Load < 1.5 % 
  • Maximum Over speed: 2250 rev/min 

Battery Charger & Electrical System Data 

  • Manufacturer: ComAp 
  • Model: InteliCharger 
  • Input Voltage: 85V ~ 264V AC 
  • Output Voltage / Current: 27.2V Float / 2.5A pk 

Jacket Water Heater Data 

  • Manufacturer: Hotstart 
  • Model: CTM25110-N00 
  • Input Voltage: 120V 
  • Power: 2500W 

Controller Data 

  • Manufacturer: DSE 
  • Model: 7320 MK II 

Controller Features & Benefits 

  • Microprocessor controlled, UL & NFPA110 Compatible 
  • License free PC Software (Non-proprietary Software) 
  • IP65 rating offers increased resistance to water ingress 
  • Modules can be integrated to building management systems 
  • Real time clock provides accurate event log 
  • Four line back-lit LCD text display 
  • Five key menu navigation, two wire start/stop at Auto mode 
  • Front panel editing with PIN protection 
  • Support up to three remote display modules 
  • Configurable timers and alarms 
  • Multiple date and timer scheduler 
  • Integral PLC editor 
  • ‘Protections disabled’ feature 
  • Load switching (load shedding and dummy load outputs) 
  • Fully configurable via DSE Configuration Suite PC Software 
  • SCADA monitoring via DSE Configuration Suite PC Software 

Protection 

  • Gen. Voltage – under / over 
  • Gen. Freq. – under / over 
  • Engine Speed – under / over 
  • Engine Oil Pressure – low 
  • Engine Temp – low / high 
  • Battery Voltage – low / high 
  • Weak Battery 
  • Fail to Start / Stop 
  • Charge Alternator Fail 
  • Over Current & Load (kW/kVAr) 
  • Unbalanced Load 
  • Independent Earth Fault 
  • Reverse Power 
  • Loss of Speed Signal 

Instruments 

  • Gen. Voltage (L-L/L-N) 
  • Gen. Frequency 
  • Engine speed 
  • Oil Pressure 
  • Water Temperature 
  • Battery Voltage 
  • Run Time 
  • Phase Sequence 
  • Power monitoring (kWh/kVAh/kVArh) 
  • Power (kWh/kVAh/kVArh) 
  • Power Factor 
  • Generator Current 
  • Generator Load (%) 
  • Earth Current 

Enclosure Features 

  • Heavy Duty Steel / Aluminum Structure 
  • E-Stop on Enclosure 
  • Control Panel Eliminated from Engine Vibrations 
  • Standard Sound Attenuation Foam 
  • Plastic Covered Corrosion Resistant Locks & Hinges 
  • Internally Mounted Exhaust System with Rain Cap 
  • Coolant Fill Cap 
  • Removable Base Frame Lifting Hooks 
  • Oil & Coolant Drain Ports 
  • Easy Access for Maintenance 

Enclosure & Skid Dimensions 

  • Open Skid Gen: Length 157.5 in, Width w/o lift hooks 74.8 in, Height 75.8 in, Dry Weight 9085 lb 
  • Level 1 Enclosure: Length 205 in, Width w/o lift hooks 77 in, Height 89.9 in, Dry Weight 14030 lb, Sound Pressure @ 7m 79 dB(A) 
  • Level 2 Enclosure: Length 224.6 in, Width w/o lift hooks 77 in, Height 89.9 in, Dry Weight 14405 lb, Sound Pressure @ 7m 77 dB(A) 

Fuel Tank – UL142 Listed Base Design 

  • 24hr (1000gal): Dimensions 225/74.8/22 in, Weight 3400 lb 
  • 48hr (1780gal): Dimensions 225/74.8/35 in, Weight 4350 lb 
  • 72hr (3000gal): Dimensions 350/74.8/36 in, Weight 6200 lb 

Standard Features & Accessories 

  • UL2200 Certification 
  • Heavy Duty Steel Base Frame 
  • PMG w/MX341 AVR 
  • Engine Jacket Water Heater 
  • Battery and Battery Rack 
  • Battery Charger 
  • Anti Vibration Pads between Engine/Alternator & Base Frame 
  • Critical Grade Silencer Inside Enclosure 
  • Residential Grade Silencer Set for Open Skid Sets 
  • Exhaust outlet rain cap and radiator fill cap 
  • Sound Absorb Foam Material for Enclosure 
  • Emergency Stop Button 
  • Oil Drain Valve 
  • Coolant Drain Valve 
  • Jacket Water Heater Isolation Valves 
  • Flex Fuel Lines 
  • Air Filter Restriction Gauge 
  • Engine Manifold Cover 
  • Turbocharger Cover 
  • Protection Covers for Rotating Parts 
  • Exhaust Insulation Cover 
  • Enclosure DC Light 
  • Operations Manual 
  • 24 Months / 2000 hours Limited Standby Warranty 

Optional Accessories 

  • Main Line CB (3/4 Poles – 80%/100% rated) 
  • Upsize Alternator 
  • Voltage Regulation ±0.5% w/MX321 AVR 
  • Anti-condensation Heater 
  • Sub Base Fuel Tank (UL142 / UL2085) 
  • Fuel Level Display & Alarm on Controller 
  • Low / High Fuel Alarms 
  • Fuel Water Separator Filter 
  • Auto Fuel Fill Control System 
  • Oil Temperature Display on Controller 
  • Manual Speed Adjust Rheostat 
  • Manual Voltage Adjust Rheostat 
  • Remote Annunciator Panel 
  • Remote Control & Monitoring Panel 
  • Advanced SMS Messaging 
  • Control Panel Heater 
  • Battery Disconnect Switch 
  • Battery Heater 
  • Battery Charger 10/20 Amp 
  • Shunt Trip / Aux Contacts 
  • Spring Anti-vibration Isolators 
  • Automatic Transfer Panel (ATS) 
  • 5 Years / 2000 hours Limited Comprehensive Warranty 

Codes & Standards 

  • Designed and manufactured in a facility certified to ISO9001 standards 
  • Designed and manufactured in a facility certified to ISO14001:2015 standards 
  • AKSA Power Generation provides single source responsibility for the generator set & accessories 
  • Prototype tested and production tested according to the UL test program 
  • Meets NFPA70, 99, 110, 37 Level 1 when equipped with necessary accessories and installed per NFPA standards 
  • EPA – Certified for Emergency Stationary Applications 

product specifications:

SpecificationValue
Model NameAPD-ULV550
Engine MakeVolvo
Engine ModelTAD1642GE
Alternator MakeStamford
Control Panel Make & ModelDSE 7320 MK II
Frequency & Speed60Hz, 1800 rpm
Enclosure Make & ModelAKSA AUL 71/72
Standby Power Rating550 kW
Standby Voltage480/277V
Power Factor0.8
Standby Current827A
Engine ManufacturerVolvo Penta
Displacement & Cylinders16.12 L / 6 Cylinders
Engine Speed1800 rpm
Engine Standby Power585 kW
Engine Prime Power532 kW
AspirationTurbocharged
Compression Ratio16.5 : 1
Bore / Stroke144 mm / 165 mm
Effective Mean Pressure, Standby Power2.5 Mpa
Max Combustion Pressure, Standby Power18.9 Mpa
Total Mass Moment of Inertia4.20 kgm2
Friction Power53 kW
Wet Weight - Engine Only3417 lb
Wet Weight - GenPac4453 lb
Engine Crankcase Vent SystemOpen
Injection Pump TypeDelphi / E1
System Supply Flow53 g/h
System Return Flow6.6 g/h
Max Allowable Inlet Fuel Temp140 F
Fuel Consumption - Standby Power (100%)38.5 gal/h
Fuel Consumption - Standby Power (75%)27.8 gal/h
Fuel Consumption - Standby Power (50%)18.5 gal/h
Fuel Consumption - Standby Power (25%)10.0 gal/h
Electric System Voltage & Type24V, Insulated from Earth
Charging Alternator Make / OutputBosch / 80A
Battery Qty, Rating2 x 120Ah
Radiator Cooling System TypeClosed Circuit
Fan Power Consumption19 kW
Coolant Capacity15.85 gal
Max Top Tank Temperature217 F
Thermostat, Start - Fully Open187-205 F
Exhaust Gas Temp954 C
Max Allowable Back Pressure10 kPa
Exhaust Gas Flow117.6 m3/min
Air Consumption46.6 m3/min
Max Intake Air Restriction5 kPa
Air Filter TypeSingle Stage Paper Cartridge
Total Lubrication System Capacity12.7 gal
Sump Capacity Max / Min11.1 gal / 8.5 gal
Max Oil Temp266 C
Oil Pressure at Rated Speed44-94 psi
Oil Consumption0.032 gal/h
Alternator StandardsBS EN 60034
Alternator Control SystemPMG
A.V.R.MX341
Voltage Regulation+/- 1%
Insulation SystemClass H
Alternator ProtectionIP23
Rated Power Factor0.8
Stator WindingDouble Layer Concentric
Winding PitchTwo Thirds
Winding Leads12
Telephone InterferenceTHF < 2%
Waveform DistortionNo Load < 1.5%
Maximum Over Speed2250 rev/min
Battery Charger ManufacturerComAp
Battery Charger ModelInteliCharger
Battery Charger Input Voltage85V ~ 264V AC
Battery Charger Output Voltage / Current27.2V Float / 2.5A pk
Jacket Water Heater ManufacturerHotstart
Jacket Water Heater ModelCTM25110-N00
Jacket Water Heater Input Voltage120V
Jacket Water Heater Power2500W
Controller ManufacturerDSE
Controller Model7320 MK II
Open Skid Length157.5 in
Open Skid Width w/o lift hooks74.8 in
Open Skid Height75.8 in
Open Skid Dry Weight9085 lb
Level 1 Enclosure Length205 in
Level 1 Enclosure Width w/o lift hooks77 in
Level 1 Enclosure Height89.9 in
Level 1 Enclosure Dry Weight14030 lb
Level 1 Sound Pressure @ 7 meters79 dB(A)
Level 2 Enclosure Length224.6 in
Level 2 Enclosure Width w/o lift hooks77 in
Level 2 Enclosure Height89.9 in
Level 2 Enclosure Dry Weight14405 lb
Level 2 Sound Pressure @ 7 meters77 dB(A)
Fuel Tank 24hr (1000gal) Dimensions (L/W/H)225 / 74.8 / 22 in
Fuel Tank 24hr (1000gal) Weight3400 lb
Fuel Tank 48hr (1780gal) Dimensions (L/W/H)225 / 74.8 / 35 in
Fuel Tank 48hr (1780gal) Weight4350 lb
Fuel Tank 72hr (3000gal) Dimensions (L/W/H)350 / 74.8 / 36 in
Fuel Tank 72hr (3000gal) Weight6200 lb

 

product related documents:

APD-ULV550.pdf

Additional Info
Peso14405 lbs
Dimensiones224.6 × 77 × 89.9 in
Reviews

Valoraciones

No hay valoraciones aún.

Solo los usuarios registrados que hayan comprado este producto pueden hacer una valoración.

Item añadido al carrito View Cart Checkout
Item added to wishlist View Wishlist
Item removed from wishlist