A 400 kW natural gas / 300 kW LP gas standby generator set built by AKSA Power Generation around a PSI (Doosan) 21.9L engine and a Stamford alternator, controlled by a DSE 7320 MK II panel. Rated for 60Hz, 1800 rpm operation and UL2200-certified for emergency stationary applications, the APD-NG400 is engineered for reliable commercial and industrial standby power in a heavy-duty steel and aluminum enclosure. 

Key Features 

  • 400 kW Natural Gas / 300 kW LP Gas standby power output 
  • PSI (Doosan) 21.9L, 12-cylinder, turbocharged, electronically governed engine 
  • Stamford HCI444F alternator with Class H insulation and ±1% voltage regulation 
  • DSE 7320 MK II microprocessor-based control panel, UL & NFPA 110 compatible 
  • Multiple voltage configurations available: 480/277V, 240/120V, 208/120V, and 600/347V 
  • UL2200 certified and designed for NFPA 70, 99, 110, and 37 Level 1 applications 
  • Heavy-duty steel/aluminum enclosure with standard sound attenuation foam 
  • Engine jacket water heater, battery charger, and battery rack included standard 
  • 24 months / 2,000 hours limited standby warranty 
Share:
Descripción
Additional Info
Reviews
Descripción

 

APD-NG400 product details and specifications:

General Characteristics 

  • Model Name: APD-NG400 
  • Engine Make: PSI (Doosan) 
  • Engine Model: 21.9L 
  • Alternator Make: Stamford 
  • Control Panel Make & Model: DSE 7320 
  • Frequency & Speed: 60Hz, 1800 rpm 
  • Enclosure Make & Model: AKSA AUL 71A/72A 

Genset Rating 

  • 480/277V, PF 0.8: 400kW NG Standby (602A) / 300kW LP Gas Standby (451A) 
  • 240/120V, PF 0.8: 360kW NG Standby (1082A) / 300kW LP Gas Standby (903A) 
  • 208/120V, PF 0.8: 360kW NG Standby (1249A) / 300kW LP Gas Standby (1042A) 
  • 600/347V, PF 0.8: 400kW NG Standby (481A) / 300kW LP Gas Standby (361A) 
  • EPA – Certified for Emergency Stationary Applications 

Engine Data 

  • Manufacturer: PSI 
  • Model: NGE 21.9L 
  • Displacement & Cylinders: 21.9 L / 12 Cylinders 
  • Engine Type: V-type, 4 Cycle 
  • Engine Speed: 1800 rpm 
  • Engine Standby Power NG: 510 kW 
  • Engine Standby Power LP: 352 kW 
  • Aspiration: Turbo Charge Air Cooled 
  • Compression Ratio: 10.5:1 
  • Bore / Stroke: 128 mm / 142 mm 
  • Governor Type: Electronic 

Fuel System 

  • Fuel Type: NG, LP Gas/Dual Fuel 
  • NG Supply Pipe Size: 2.0” NPTF 
  • Maximum EPR Rated Pressure: 6.9 kPa / 1.0 psi 
  • Recommended Max Pressure: 2.7 kPa / 11.0 inH2O 
  • Recommended Min Pressure: 1.7 kPa / 7.0 inH2O 
  • Max LPG Vapor Pressure to EPR: 2.7 kPa / 11.0 inH2O 

Fuel Consumption 

  • Natural Gas, Standby Power (100%): 5,375 ft³/h (152 m³/h) 
  • LP Gas, Standby Power (100%): 44 gal/h (166 L/h) 

Electric System 

  • System Voltage (dc): 24V 
  • Battery Qty, Rating: 2 x 120Ah 

Cooling System 

  • Radiator Cooling System Type: Closed Circuit 
  • Coolant Capacity: 51 gal 
  • Cranking Temperature: 160°F 
  • Full Open Temperature: 185°F 

Exhaust System 

  • Type: Water Cooled Manifold 
  • Max. Allowable Back Pressure: 10.2 kPa 
  • Max Turbine Outlet Temperature: 1136°F 
  • Exhaust Gas Flow at Turbine Outlet Temperature: 2821 cfm 

Air Intake System 

  • Combustion Air Required: 829 cfm 
  • Max Intake Air Restriction (Clean Element): 1.2 kPa / 5 inH2O 
  • Air Filter Type: Dry Paper Element 

Lubrication System 

  • Oil Specifications: SAE 15W-40 Low Ash Gas Engine Oil, API CD/CF or higher 
  • Oil Capacity, Min-Max: 35–42.4 Qts 
  • Oil Filter: 2, Cartridge 
  • Min – Max Oil Pressure @ 1000 rpm (Idle): 13 psi – 44 psi (0.9 bar – 3 bar) 

Alternator Data 

  • Manufacturer: Stamford 
  • Standards: BS EN 60034 
  • Control System: PMG 
  • A.V.R.: MX341 
  • Voltage Regulation: ± 1% 
  • Insulation System: Class H 
  • Protection: IP23 
  • Rated Power Factor: 0.8 
  • Stator Winding: Double Layer Concentric 
  • Winding Pitch: Two Thirds 
  • Winding Leads: 12 
  • Telephone Interference: THF < 2% 
  • Waveform Distortion: No Load < 1.5% 
  • Maximum Over Speed: 2250 rev/min 

Controller Data 

  • Manufacturer: DSE 
  • Model: 7320 MK II 
  • Microprocessor controlled, UL & NFPA110 Compatible 
  • License free PC Software (Non-proprietary Software) 
  • IP65 rating offers increased resistance to water ingress 
  • Modules can be integrated to building management systems 
  • Real time clock provides accurate event log 
  • Four line back-lit LCD text display 
  • Five key menu navigation, two wire start/stop at Auto mode 
  • Front panel editing with PIN protection 
  • Support up to three remote display modules 
  • Configurable timers and alarms 
  • Multiple date and timer scheduler 
  • Integral PLC editor 
  • ‘Protections disabled’ feature 
  • Load switching (load shedding and dummy load outputs) 
  • Fully configurable via DSE Configuration Suite PC Software 
  • SCADA monitoring via DSE Configuration Suite PC Software 

Protection & Instruments 

  • Gen. Voltage – under / over; Gen. Voltage (L-L/L-N) 
  • Gen. Freq. – under / over; Gen. Frequency 
  • Engine Speed – under / over; Engine speed 
  • Engine Oil Pressure – low; Oil Pressure 
  • Engine Temp – low / high; Water Temperature 
  • Battery Voltage – low / high; Battery Voltage 
  • Weak Battery; Run Time 
  • Fail to Start / Stop; Phase Sequence 
  • Charge Alternator Fail; Power monitoring (kWh/kVAh/kVArh) 
  • Over Current & Load (kW/kVAr); Power (kWh/kVAh/kVArh) 
  • Unbalanced Load; Power Factor 
  • Independent Earth Fault; Generator Current 
  • Reverse Power; Generator Load (%) 
  • Loss of Speed Signal; Earth Current 

Battery Charger & Electrical System Data 

  • Manufacturer: ComAp 
  • Model: InteliCharger 
  • Input Voltage: 85V ~ 264V AC 
  • Output Voltage / Current: 13.8V Float / 4A pk 

Jacket Water Heater Data 

  • Manufacturer: Hotstart 
  • Model: CTM25110-N00 
  • Input Voltage: 120V 
  • Power: 2500W 

Open Skid Gen-Set Dimensions 

  • Length: 158 in 
  • Width w/o lift hooks: 83 in 
  • Height: 87 in 
  • Dry Weight: 11,000 lb 

Enclosed Gen-Set Dimensions – Level 1 

  • Length: 206 in 
  • Width w/o lift hooks: 86 in 
  • Height: 101 in 
  • Dry Weight: 14,500 lb 
  • Sound Pressure @ 7 meters: 80 dBA 

Enclosed Gen-Set Dimensions – Level 2 

  • Length: 224.6 in 
  • Width w/o lift hooks: 86 in 
  • Height: 101 in 
  • Dry Weight: 15,000 lb 
  • Sound Pressure @ 7 meters: 77 dBA 

Enclosure Features 

  • Heavy Duty Steel / Aluminum Structure 
  • E-Stop on Enclosure 
  • Control Panel Eliminated from Engine Vibrations 
  • Standard Sound Attenuation Foam 
  • Plastic Covered Corrosion Resistant Locks & Hinges 
  • Internally Mounted Exhaust System with Rain Cap 
  • Coolant Fill Cap 
  • Removable Base Frame Lifting Hooks 
  • Oil & Coolant Drain Ports 
  • Easy Access for Maintenance 

Standard Features & Accessories 

  • UL2200 Certification 
  • Heavy Duty Steel Base Frame 
  • PMG 
  • Engine Jacket Water Heater 
  • Battery and Battery Rack 
  • Battery Charger 
  • Anti Vibration Pads between Engine/Alternator & Base Frame 
  • Critical Grade Silencer Inside Enclosure 
  • Residential Grade Silencer Set for Open Skid Sets 
  • Exhaust outlet rain cap and radiator fill cap 
  • Sound Absorb Foam Material for Enclosure 
  • Emergency Stop Button 
  • Oil Drain Valve 
  • Coolant Drain Valve 
  • Jacket Water Heater Isolation Valves 
  • Flex Fuel Lines 
  • Secondary Lock-off Valve on Baseframe 
  • Engine Manifold Cover 
  • Turbocharger Cover 
  • Protection Covers for Rotating Parts 
  • Exhaust Insulation Cover 
  • Enclosure DC Light 
  • Operations Manual 
  • 24 Months / 2000 hours Limited Standby Warranty 

Optional Accessories 

  • Main Line CB (3/4 Poles – 80%/100% rated) 
  • Upsize Alternator 
  • Anti-condensation Heater 
  • Voltage Regulation ±0.5% w/MX321 AVR 
  • Gas Regulator 
  • NG/LP Auto Changeover Control System 
  • Low Gas Pressure Alarm 
  • Low Coolant Level Alarm 
  • Oil Pan Heater 
  • Oil Temperature Display on Controller 
  • Manual Speed Adjust Rheostat 
  • Manual Voltage Adjust Rheostat 
  • Remote Annunciator Panel 
  • Remote Control & Monitoring Panel 
  • Advanced SMS Messaging 
  • Control Panel Heater 
  • Battery Disconnect Switch 
  • Battery Heater 
  • Battery Charger 10/20 Amp 
  • Shunt Trip / Aux Contacts 
  • Spring Anti-vibration Isolators 
  • Automatic Transfer Panel (ATS) 
  • 5 Years / 2000 hours Limited Comprehensive Warranty 

Codes & Standards 

  • Designed and manufactured in a facility certified to ISO9001 standards 
  • Designed and manufactured in a facility certified to ISO14001:2015 standards 
  • AKSA Power Generation provides single source responsibility for the generator set & accessories 
  • Prototype tested and production tested according to the UL test program 
  • Meets NFPA70, 99, 110, 37 Level 1 when equipped with the necessary accessories and installed per NFPA standards (engine must be equipped with a fast start kit for NFPA110 Level 1 applications) 

product specifications:

SpecificationValue
Model NameAPD-NG400
Engine MakePSI (Doosan)
Engine Model21.9L
Alternator MakeStamford
Control Panel Make & ModelDSE 7320 MK II
Frequency & Speed60Hz, 1800 rpm
Enclosure Make & ModelAKSA AUL 71A/72A
NG Standby Power (480/277V)400 kW
LP Gas Standby Power (480/277V)300 kW
Rated Power Factor0.8
Engine Standby Power NG510 kW
Engine Standby Power LP352 kW
Displacement & Cylinders21.9 L / 12 Cylinders
Engine TypeV-type, 4 Cycle
AspirationTurbo Charge Air Cooled
Compression Ratio10.5 : 1
Bore / Stroke128 mm / 142 mm
Governor TypeElectronic
Fuel TypeNG, LP Gas/Dual Fuel
NG Supply Pipe Size2.0 in NPTF
Maximum EPR Rated Pressure1.0 psi
Recommended Max Pressure11.0 inH2O
Recommended Min Pressure7.0 inH2O
Max LPG Vapor Pressure to EPR11.0 inH2O
Natural Gas Consumption (Standby, 100%)5,375 ft3/h
LP Gas Consumption (Standby, 100%)44 gal/h
System Voltage (dc)24V
Battery Qty, Rating2 x 120Ah
Radiator Cooling System TypeClosed Circuit
Coolant Capacity51 gal
Cranking Temperature160 F
Full Open Temperature185 F
Exhaust TypeWater Cooled Manifold
Max. Allowable Back Pressure10.2 kPa
Max Turbine Outlet Temperature1136 F
Exhaust Gas Flow at Turbine Outlet2821 cfm
Combustion Air Required829 cfm
Max Intake Air Restriction (Clean Element)5 inH2O
Air Filter TypeDry Paper Element
Oil SpecificationsSAE 15W-40 Low Ash Gas Engine Oil, API CD/CF or higher
Oil Capacity, Min-Max35 - 42.4 Qts
Oil Filter2, Cartridge
Min - Max Oil Pressure @ 1000 rpm (Idle)13 psi - 44 psi
Alternator StandardsBS EN 60034
Alternator Control SystemPMG
A.V.R.MX341
Voltage Regulation+/- 1 %
Insulation SystemClass H
ProtectionIP23
Stator WindingDouble Layer Concentric
Winding PitchTwo Thirds
Winding Leads12
Telephone InterferenceTHF < 2 %
Waveform DistortionNo Load < 1.5 %
Maximum Over Speed2250 rev/min
Battery Charger ManufacturerComAp
Battery Charger ModelInteliCharger
Battery Charger Input Voltage85V ~ 264V AC
Battery Charger Output Voltage / Current13.8V Float / 4A pk
Jacket Water Heater ManufacturerHotstart
Jacket Water Heater ModelCTM25110-N00
Jacket Water Heater Input Voltage120V
Jacket Water Heater Power2500W
Open Skid Length158 in
Open Skid Width w/o Lift Hooks83 in
Open Skid Height87 in
Open Skid Dry Weight11,000 lbs.
Enclosed Level 1 Length206 in
Enclosed Level 1 Width w/o Lift Hooks86 in
Enclosed Level 1 Height101 in
Enclosed Level 1 Dry Weight14,500 lbs.
Enclosed Level 1 Sound Pressure @ 7m80 dBA
Enclosed Level 2 Length224.6 in
Enclosed Level 2 Width w/o Lift Hooks86 in
Enclosed Level 2 Height101 in
Enclosed Level 2 Dry Weight15,000 lbs.
Enclosed Level 2 Sound Pressure @ 7m77 dBA
Warranty24 Months / 2000 hours Limited Standby Warranty

 

product related documents:

APD-NG400.pdf

Additional Info
Peso15000 lbs
Dimensiones224.6 × 86 × 101 in
Reviews

Valoraciones

No hay valoraciones aún.

Solo los usuarios registrados que hayan comprado este producto pueden hacer una valoración.

Item añadido al carrito View Cart Checkout
Item added to wishlist View Wishlist
Item removed from wishlist