Aksa Diesel Generator APD-ULJ100 (100kW)



Aksa Diesel Generator APD-ULJ100 (100kW)
Call for Price
The APD-ULJ100 is a 100 kW diesel standby generator set built by AKSA Power Generation, powered by a turbocharged John Deere 4045HF285 engine and paired with a Stamford UCI274 alternator for reliable, high-quality power output. Controlled by a DSE 7320 microprocessor-based control panel, this UL2200-listed unit is designed and prototype/production tested for emergency stationary applications, meeting NFPA 70, 99, 110, and 37 Level 1 standards when properly installed. Available on an open skid or in a sound-attenuated Level 1 or Level 2 enclosure, the APD-ULJ100 delivers dependable backup power for commercial and industrial facilities.
Key Features
- 100 kW standby power at 480/277V, 208/120V, 240/120V (1-phase & 3-phase), and 600/347V configurations
- John Deere 4045HF285 turbocharged diesel engine, 60 Hz / 1800 RPM, EPA Tier 3 certified
- Stamford UCI274 alternator with Class H insulation and IP23 protection
- DSE 7320 MK II microprocessor control panel with UL & NFPA110 compatibility
- UL2200 listed and EPA certified for emergency stationary applications
- Available as open skid, Level 1 enclosure, or Level 2 sound-attenuated enclosure
- Heavy-duty steel base frame with anti-vibration pads and critical grade silencer
- Engine jacket water heater, battery charger, and battery rack included standard
- UL142-listed sub-base fuel tank options for 24, 48, or 72-hour runtime
- 24 months / 2,000 hours limited standby warranty
APD-ULJ100 product details and specifications:
General Characteristics
- Model Name: APD-ULJ100
- Engine Make: John Deere
- Engine Model: 4045HF285
- Alternator Make: Stamford
- Control Panel Make & Model: DSE 7320
- Frequency & Speed: 60Hz, 1800rpm
- Enclosure Make & Model: AKSA AUL 41/42
- Certification: UL2200 Diesel
Genset Rating
- 480 / 277V, 3-phase: 100kW, 0.8 PF, 150A (Alternator: UCI274C, Wnd-311)
- 240 / 120V, 1-phase: 97kW, 1.0 PF, 405A (Alternator: UCI274D, Wnd-06)
- 208 / 120V, 3-phase: 100kW, 0.8 PF, 347A (Alternator: UCI274D, Wnd-311)
- 600 / 347V, 3-phase: 96kW, 0.8 PF, 115A (Alternator: UCI274C, Wnd-17)
- 240 / 120V, 3-phase: 100kW, 0.8 PF, 300.7A (Alternator: UCI274D, Wnd-311)
Codes & Standards
- Designed and manufactured in a facility certified to ISO9001 standards
- Designed and manufactured in a facility certified to ISO14001:2015 standards
- AKSA Power Generation provides single source responsibility for the generator set & accessories
- Prototype tested and production tested according to the UL test program
- Meets NFPA70, 99, 110, 37 Level 1 when equipped with necessary accessories and installed per NFPA standards
Engine Data
- Manufacturer: John Deere
- Model: 4045HF285
- Displacement & Cylinders: 4.5 L / 4 Cylinders
- Engine Type: In-line, 4 Cycle
- Engine Speed: 1800rpm
- Engine Prime Power: 107kW
- Engine Standby Power: 118kW
- Aspiration: Turbocharged
- Compression Ratio: 19.0 : 1
- Bore / Stroke: 106 mm / 127 mm
- Governor Type: Electronic
- Engine Crankcase Vent System: Open
- Ratio, Air : Fuel: 21 : 1
- BMEP, Standby Power: 1748 kPa
- Friction Power: 13kW
- Designed / Calibrated to Meet: EPA Tier 3
Fuel System
- ECU Description: L16 Control
- Max Fuel Inlet Temp.: 176 F
- Total Fuel Flow: 140 lb/hr
- Fuel Consumption at Standby Power (100%): 8.21 gal/h
- Fuel Consumption at Standby Power (75%): 6.56 gal/h
- Fuel Consumption at Standby Power (50%): 4.69 gal/h
- Fuel Consumption at Standby Power (25%): 2.50 gal/h
Electric System
- System Voltage: 12V
- Min Voltage at ECU during Crank: 6V
- Battery Qty, Rating, CCA: 1 x 60Ah
Cooling System
- Radiator Cooling System Type: Closed Circuit
- Radiator Ambient Temp: Greater than 50 C
- Coolant Capacity, Engine Only: 9 quart
- Max Top Tank Temp: 230 F
- Thermostat, Start - Fully Open: 180-203 F
Exhaust & Air Intake System
- Exhaust Temperature: 1076 F
- Max Allowable Exhaust Restriction: 7.5 kPa
- Exhaust Gas Flow: 801 ft3/min
- Engine Air Flow: 288 ft3/min
- Max Intake Air Restriction (Clean Element): 3.75 kPa
- Air Filter Type: Dry Paper Element
Lubrication System
- Oil Pressure at Rated Speed: 320 kPa
- Oil Pressure at Low Idle: 105 kPa
- Max Oil Carryover in Blow-by: 0.002 lb/hr
- Max Crankcase Pressure: 0.5 kPa
Alternator Data
- Manufacturer: Stamford
- Standards: BS EN 60034
- Control System: PMG
- A.V.R.: MX341
- Voltage Regulation: +/- 1%
- Insulation System: Class H
- Protection: IP23
- Rated Power Factor: 0.8
- Stator Winding: Double Layer Concentric
- Winding Pitch: Two Thirds
- Winding Leads: 12
- Telephone Interference: THF less than 2%
- Waveform Distortion: No Load less than 1.5%
- Maximum Overspeed: 2250 rev/min
Controller Data
- Manufacturer: DSE
- Model: 7320 MK II
- Microprocessor controlled, UL & NFPA110 Compatible
- License free PC Software (Non-proprietary Software)
- IP65 rating offers increased resistance to water ingress
- Modules can be integrated to building management systems
- Real time clock provides accurate event log
- Four line back-lit LCD text display
- Five key menu navigation, two wire start/stop at Auto mode
- Front panel editing with PIN protection
- Support up to three remote display modules
- Configurable timers and alarms
- Multiple date and timer scheduler
- Integral PLC editor
- Fully configurable via DSE Configuration Suite PC Software
- SCADA monitoring via DSE Configuration Suite PC Software
Battery Charger & Electrical System Data
- Manufacturer: ComAp
- Model: InteliCharger
- Input Voltage: 85V ~ 264V AC
- Output Voltage / Current: 13.8V Float / 4A pk
Jacket Water Heater Data
- Manufacturer: Hotstart
- Model: TPS101GT10-000
- Input Voltage: 120V
- Power: 1000W
Enclosure & Dimensions
- Open Skid Gen: 92.1 in (L) x 43.3 in (W) x 53.5 in (H), 2600 lb dry weight
- Level 1 Enclosure: 116.5 in (L) x 43.3 in (W) x 66.3 in (H), 3800 lb dry weight, 70 dB(A) sound pressure @ 7m
- Level 2 Enclosure: 116.5 in (L) x 43.3 in (W) x 82 in (H), 4100 lb dry weight, 67 dB(A) sound pressure @ 7m
- Heavy Duty Steel / Aluminum Structure
- E-Stop on Enclosure
- Control Panel Eliminated from Engine Vibrations
- Standard Sound Attenuation Foam
- Plastic Covered Corrosion Resistant Locks & Hinges
- Internally Mounted Exhaust System with Rain Cap
- Coolant Fill Cap
- Removable Base Frame Lifting Hooks
- Oil & Coolant Drain Ports
- Easy Access for Maintenance
Fuel Tank (UL142 Listed Base Design)
- 24hr Tank: 190 gal, 130 x 43.3 x 15.5 in, 1260 lb
- 48hr Tank: 390 gal, 130 x 43.3 x 28.5 in, 1750 lb
- 72hr Tank: 590 gal, 145 x 43.3 x 36 in, 2180 lb
Standard Features & Accessories
- UL2200 Certification
- Heavy Duty Steel Base Frame
- PMG w/MX341 AVR
- Engine Jacket Water Heater
- Battery and Battery Rack
- Battery Charger
- Anti Vibration Pads between Engine/Alternator & Base Frame
- Critical Grade Silencer Inside Enclosure
- Residential Grade Silencer Set for Open Skid Sets
- Exhaust outlet rain cap and radiator fill cap
- Sound Absorb Foam Material for Enclosure
- Emergency Stop Button
- Oil Drain Valve
- Coolant Drain Valve
- Jacket Water Heater Isolation Valves
- Flex Fuel Lines
- Air Filter Restriction Gauge
- Engine Manifold Cover
- Turbocharger Cover
- Protection Covers for Rotating Parts
- Exhaust Insulation Cover
- Enclosure DC Light
- Operations Manual
- 24 Months / 2000 hours Limited Standby Warranty
Optional Accessories
- Main Line CB (3 / 4 Poles - 80% / 100% rated)
- Upsize Alternator
- Voltage Regulation +/-0.5% w/MX321 AVR
- Anti-condensation Heater
- Sub Base Fuel Tank (UL142 / UL2085)
- Fuel Level Display & Alarm on Controller
- Low / High Fuel Alarms
- Fuel Water Separator Filter
- Auto Fuel Fill Control System
- Oil Temperature Display on Controller
- Manual Speed Adjust Rheostat
- Manual Voltage Adjust Rheostat
- Remote Annunciator Panel
- Remote Control & Monitoring Panel
- Advanced SMS Messaging
- Control Panel Heater
- Battery Disconnect Switch
- Battery Heater
- Battery Charger 10/20 Amp
- Shunt Trip / Aux Contacts
- Spring Anti-vibration Isolators
- Automatic Transfer Panel (ATS)
- 5 Years / 2000 hours Limited Comprehensive Warranty
product specifications:
| Specification | Value |
| Model Name | APD-ULJ100 |
| Engine Make | John Deere |
| Engine Model | 4045HF285 |
| Alternator Make | Stamford |
| Control Panel Make & Model | DSE 7320 MK II |
| Frequency & Speed | 60 Hz, 1800 RPM |
| Enclosure Make & Model | AKSA AUL 41/42 |
| Standby Power (480/277V, 0.8 PF) | 100 kW / 150A |
| Standby Power (240/120V 1ph, 1.0 PF) | 97 kW / 405A |
| Standby Power (208/120V, 0.8 PF) | 100 kW / 347A |
| Standby Power (600/347V, 0.8 PF) | 96 kW / 115A |
| Standby Power (240/120V, 0.8 PF) | 100 kW / 300.7A |
| Certification | UL2200 Diesel, EPA Certified for Emergency Stationary Applications |
| Codes & Standards | ISO 9001, ISO 14001:2015, NFPA 70/99/110/37 Level 1 |
| Engine Displacement & Cylinders | 4.5 L / 4 Cylinders |
| Engine Type | In-line, 4 Cycle |
| Engine Speed | 1800 RPM |
| Engine Prime Power | 107 kW |
| Engine Standby Power | 118 kW |
| Aspiration | Turbocharged |
| Compression Ratio | 19.0 : 1 |
| Bore / Stroke | 106 mm / 127 mm |
| Governor Type | Electronic |
| Engine Crankcase Vent System | Open |
| Ratio, Air : Fuel | 21 : 1 |
| BMEP, Standby Power | 1748 kPa |
| Friction Power | 13 kW |
| Emissions Compliance | EPA Tier 3 |
| ECU Description | L16 Control |
| Max Fuel Inlet Temp. | 176 F |
| Total Fuel Flow | 140 lb/hr |
| Fuel Consumption - Standby 100% | 8.21 gal/h |
| Fuel Consumption - Standby 75% | 6.56 gal/h |
| Fuel Consumption - Standby 50% | 4.69 gal/h |
| Fuel Consumption - Standby 25% | 2.50 gal/h |
| System Voltage | 12V |
| Min Voltage at ECU During Crank | 6V |
| Battery Qty, Rating, CCA | 1 x 60Ah |
| Radiator Cooling System Type | Closed Circuit |
| Radiator Ambient Temp | Greater than 50 C |
| Coolant Capacity, Engine Only | 9 quart |
| Max Top Tank Temp | 230 F |
| Thermostat, Start - Fully Open | 180-203 F |
| Exhaust Temperature | 1076 F |
| Max Allowable Exhaust Restriction | 7.5 kPa |
| Exhaust Gas Flow | 801 ft3/min |
| Engine Air Flow | 288 ft3/min |
| Max Intake Air Restriction (Clean Element) | 3.75 kPa |
| Air Filter Type | Dry Paper Element |
| Oil Pressure at Rated Speed | 320 kPa |
| Oil Pressure at Low Idle | 105 kPa |
| Max Oil Carryover in Blow-by | 0.002 lb/hr |
| Max Crankcase Pressure | 0.5 kPa |
| Alternator Standards | BS EN 60034 |
| Alternator Control System | PMG |
| A.V.R. | MX341 |
| Voltage Regulation | +/- 1% |
| Insulation System | Class H |
| Protection | IP23 |
| Rated Power Factor | 0.8 |
| Stator Winding | Double Layer Concentric |
| Winding Pitch | Two Thirds |
| Winding Leads | 12 |
| Telephone Interference | THF less than 2% |
| Waveform Distortion | No Load less than 1.5% |
| Maximum Overspeed | 2250 rev/min |
| Battery Charger Manufacturer | ComAp |
| Battery Charger Model | InteliCharger |
| Battery Charger Input Voltage | 85V - 264V AC |
| Battery Charger Output Voltage / Current | 13.8V Float / 4A pk |
| Jacket Water Heater Manufacturer | Hotstart |
| Jacket Water Heater Model | TPS101GT10-000 |
| Jacket Water Heater Input Voltage | 120V |
| Jacket Water Heater Power | 1000W |
| Open Skid Length | 92.1 in |
| Open Skid Width (w/o lift hooks) | 43.3 in |
| Open Skid Height | 53.5 in |
| Open Skid Dry Weight | 2600 lb |
| Level 1 Enclosure Length | 116.5 in |
| Level 1 Enclosure Width (w/o lift hooks) | 43.3 in |
| Level 1 Enclosure Height | 66.3 in |
| Level 1 Enclosure Dry Weight | 3800 lb |
| Level 1 Enclosure Sound Pressure @ 7m | 70 dB(A) |
| Level 2 Enclosure Length | 116.5 in |
| Level 2 Enclosure Width (w/o lift hooks) | 43.3 in |
| Level 2 Enclosure Height | 82 in |
| Level 2 Enclosure Dry Weight | 4100 lb |
| Level 2 Enclosure Sound Pressure @ 7m | 67 dB(A) |
| Fuel Tank Size - 24hr | 190 gal, 130 x 43.3 x 15.5 in, 1260 lb |
| Fuel Tank Size - 48hr | 390 gal, 130 x 43.3 x 28.5 in, 1750 lb |
| Fuel Tank Size - 72hr | 590 gal, 145 x 43.3 x 36 in, 2180 lb |
| Warranty | 24 Months / 2000 hours Limited Standby Warranty |
product related documents:
| Peso | 4100 lbs |
|---|---|
| Dimensiones | 116.5 × 43.3 × 82 in |
Solo los usuarios registrados que hayan comprado este producto pueden hacer una valoración.





Valoraciones
No hay valoraciones aún.