Aksa APD-ULV500 (500kW)



Aksa APD-ULV500 (500kW)
Call for Price
The AKSA Power Generation APD-ULV500 is a 500 kW standby diesel generator set built around a Volvo Penta TAD1641GE engine and a Stamford alternator, packaged with a DSE 7320 MK II control panel. Designed and manufactured to ISO9001 and ISO14001 standards, the unit is UL2200 listed and meets NFPA70, 99, 110 and 37 Level 1 requirements, making it well suited for emergency stationary standby applications. It is available in multiple voltage configurations and enclosure options, from an open skid to a Level 2 sound-attenuated enclosure, with optional UL142 listed sub-base fuel tanks for extended runtime.
Key Features
- 500 kW standby / 485 kW prime power diesel generator set powered by a Volvo Penta TAD1641GE engine
- Stamford HCI alternator with PMG excitation and MX341 AVR for ±1% voltage regulation
- DSE 7320 MK II microprocessor controller with UL & NFPA110 compatibility and SCADA monitoring
- UL2200 listed and meets NFPA70, 99, 110 & 37 Level 1 requirements
- Available in 480/277V, 240/120V, 208/120V, and 600/347V configurations, 60Hz, 1800rpm
- Heavy duty steel/aluminum enclosure with sound attenuation foam and critical grade silencer
- Offered as open skid, Level 1, or Level 2 sound-attenuated enclosure configurations
- UL142 listed sub-base fuel tank options available in 24hr, 48hr, and 72hr capacities
- Backed by a 24 month / 2000 hour limited standby warranty (5-year comprehensive warranty optional)
APD-ULV500 product details and specifications:
General Characteristics
- Model Name: APD-ULV500
- Engine Make: Volvo
- Engine Model: TAD1641GE
- Alternator Make: Stamford
- Control Panel Make & Model: DSE 7320
- Frequency & Speed: 60Hz, 1800rpm
- Enclosure Make & Model: AKSA AUL 71/72
Genset Rating
- Engine: TAD1641GE, Standby Power: 500kW, Power Factor: 0.8
- 480/277V - Standby Current 752A
- 240/120V - Standby Current 1504A
- 208/120V - Standby Current 1735A
- 600/347V - Standby Current 601A
Engine Data
- Manufacturer: Volvo Penta
- Model: TAD1641GE
- Displacement & Cylinders: 16.12 L / 6 Cylinders
- Engine Speed: 1800rpm
- Engine Standby Power: 546 kW
- Engine Prime Power: 485 kW
- Aspiration: Turbocharged
- Compression Ratio: 16.5 : 1
- Bore / Stroke: 144mm / 165mm
- Effective Mean Pressure, Standby Power: 2.3 Mpa
- Max Combustion Pressure, Standby Power: 18.2 Mpa
- Total Mass Moment of Inertia: 4.20 kgm2
- Friction Power: 53 kW
- Wet Weight - Engine Only: 3417 lbs.
- Wet Weight - GenPac: 4453 lbs.
- Engine Crankcase Vent System: Open
Fuel System
- Injection Pump Type: Delphi / E1
- System Supply Flow: 50 g/h
- System Return Flow: 6.6 g/h
- Max Allowable Inlet Fuel Temp: 140˚F
Fuel Consumption
- Standby Power (100%): 35.5 gal/h
- Standby Power (75%): 25.9 gal/h
- Standby Power (50%): 17.4 gal/h
- Standby Power (25%): 9.9 gal/h
Electric System
- Voltage & Type: 24V, Insulated from Earth
- Alternator Make / Output: Bosch / 80A
- Battery Qty, Rating: 2 x 120Ah
Cooling System
- Radiator Cooling System Type: Closed Circuit
- Fan Power Consumption: 19 kW
- Coolant Capacity: 15.85 gal
- Max Top Tank Temperature: 217˚F
- Thermostat, Start - Fully Open: 187-205˚F
Exhaust System
- Exhaust Gas Temp: 893˚F
- Max Allowable Back Pressure: 10 kPa
- Exhaust Gas Flow: 110.4 m3/min
Air Intake System
- Air Consumption: 45.8 m3/min
- Max Intake Air Restriction: 5 kPa
- Air Filter Type: Single Stage Paper Cartridge
Lubrication System
- Total System Capacity: 12.7 gal
- Sump Capacity Max / Min: 11.1 gal / 8.5 gal
- Max Oil Temp: 266˚F
- Oil Pressure at Rated Speed: 44-94 psi
- Oil Consumption: 0.032 gal/h
Alternator Data
- Manufacturer: Stamford
- Standards: BS EN 60034
- Control System: PMG
- A.V.R.: MX341
- Voltage Regulation: ±1%
- Insulation System: Class H
- Protection: IP23
- Rated Power Factor: 0.8
- Stator Winding: Double Layer Concentric
- Winding Pitch: Two Thirds
- Winding Leads: 12
- Telephone Interference: THF < 2%
- Waveform Distortion: No Load < 1.5%
- Maximum Over Speed: 2250 rev/min
Controller Data
- Manufacturer: DSE
- Model: 7320 MK II
Controller Features & Benefits
- Microprocessor controlled, UL & NFPA110 Compatible
- License free PC Software (Non-proprietary Software)
- IP65 rating offers increased resistance to water ingress
- Modules can be integrated to building management systems
- Real time clock provides accurate event log
- Four line back-lit LCD text display
- Five key menu navigation, two wire start/stop at Auto mode
- Front panel editing with PIN protection
- Support up to three remote display modules
- Configurable timers and alarms
- Multiple date and timer scheduler
- Integral PLC editor
- 'Protections disabled' feature
- Load switching (load shedding and dummy load outputs)
- Fully configurable via DSE Configuration Suite PC Software
- SCADA monitoring via DSE Configuration Suite PC Software
Protection
- Gen. Voltage - under / over
- Gen. Freq. - under / over
- Engine Speed - under / over
- Engine Oil Pressure - low
- Engine Temp - low / high
- Battery Voltage - low / high
- Weak Battery
- Fail to Start / Stop
- Charge Alternator Fail
- Over Current & Load (kW/kVAr)
- Unbalanced Load
- Independent Earth Fault
- Reverse Power
- Loss of Speed Signal
Instruments
- Gen. Voltage (L-L/L-N)
- Gen. Frequency
- Engine Speed
- Oil Pressure
- Water Temperature
- Battery Voltage
- Run Time
- Phase Sequence
- Power monitoring (kWh/kVAh/kVArh)
- Power (kWh/kVAh/kVArh)
- Power Factor
- Generator Current
- Generator Load (%)
- Earth Current
Battery Charger & Electrical System Data
- Manufacturer: ComAp
- Model: InteliCharger
- Input Voltage: 85V ~ 264V AC
- Output Voltage / Current: 27.2V Float / 2.5A pk
Jacket Water Heater Data
- Manufacturer: Hotstart
- Model: CTM25210-N00
- Input Voltage: 240V
- Power: 2500W
Enclosure Features
- Heavy Duty Steel / Aluminum Structure
- E-Stop on Enclosure
- Control Panel Eliminated from Engine Vibrations
- Standard Sound Attenuation Foam
- Plastic Covered Corrosion Resistant Locks & Hinges
- Internally Mounted Exhaust System with Rain Cap
- Coolant Fill Cap
- Removable Base Frame Lifting Hooks
- Oil & Coolant Drain Ports
- Easy Access for Maintenance
Enclosure Dimensions & Weight
- Open Skid Gen - Length: 157.5 in, Width w/o lift hooks: 74.8 in, Height: 75.8 in, Dry Weight: 9085 lbs.
- Level 1 Enclosure - Length: 205 in, Width w/o lift hooks: 77 in, Height: 89.9 in, Dry Weight: 14030 lbs., Sound Pressure @ 7m: 79 dB(A)
- Level 2 Enclosure - Length: 224.6 in, Width w/o lift hooks: 77 in, Height: 89.9 in, Dry Weight: 14405 lbs., Sound Pressure @ 7m: 77 dB(A)
Fuel Tank - UL142 Listed Base Design
- 24hr (855gal) - Dimensions L/W/H: 225 in / 74.8 in / 18 in, Weight: 3200 lbs.
- 48hr (1780gal) - Dimensions L/W/H: 225 in / 74.8 in / 35 in, Weight: 4350 lbs.
- 72hr (2550gal) - Dimensions L/W/H: 300 in / 74.8 in / 36 in, Weight: 5450 lbs.
Standard Features & Accessories
- UL2200 Certification
- Heavy Duty Steel Base Frame
- PMG w/MX341 AVR
- Engine Jacket Water Heater
- Battery and Battery Rack
- Battery Charger
- Anti Vibration Pads between Engine/Alternator & Base Frame
- Critical Grade Silencer Inside Enclosure
- Residential Grade Silencer Set for Open Skid Sets
- Exhaust outlet rain cap and radiator fill cap
- Sound Absorb Foam Material for Enclosure
- Emergency Stop Button
- Oil Drain Valve
- Coolant Drain Valve
- Jacket Water Heater Isolation Valves
- Flex Fuel Lines
- Air Filter Restriction Gauge
- Engine Manifold Cover
- Turbocharger Cover
- Protection Covers for Rotating Parts
- Exhaust Insulation Cover
- Enclosure DC Light
- Operations Manual
- 24 Months / 2000 hours Limited Standby Warranty
Optional Accessories
- Main Line CB (3 / 4 Poles - 80% / 100% rated)
- Upsize Alternator
- Voltage Regulation ±0.5% w/MX321 AVR
- Anti-condensation Heater
- Sub Base Fuel Tank (UL142 / UL2085)
- Fuel Level Display & Alarm on Controller
- Low / High Fuel Alarms
- Fuel Water Separator Filter
- Auto Fuel Fill Control System
- Oil Temperature Display on Controller
- Manual Speed Adjust Rheostat
- Manual Voltage Adjust Rheostat
- Remote Annunciator Panel
- Remote Control & Monitoring Panel
- Advanced SMS Messaging
- Control Panel Heater
- Battery Disconnect Switch
- Battery Heater
- Battery Charger 10/20 Amp
- Shunt Trip / Aux Contacts
- Spring Anti-vibration Isolators
- Automatic Transfer Panel (ATS)
- 5 Years / 2000 hours Limited Comprehensive Warranty
Codes & Standards
- Designed and manufactured in a facility certified to ISO9001 standards
- Designed and manufactured in a facility certified to ISO14001:2015 standards
- AKSA Power Generation provides single source responsibility for the generator set & accessories
- Prototype tested and production tested according to the UL test program
- Meets NFPA70, 99, 110, 37 Level 1 when equipped with the necessary accessories and installed per NFPA standards
product specifications:
| Specification | Value |
| General Characteristics | |
| Model Name | APD-ULV500 |
| Engine Make | Volvo |
| Engine Model | TAD1641GE |
| Alternator Make | Stamford |
| Control Panel Make & Model | DSE 7320 |
| Frequency & Speed | 60Hz, 1800rpm |
| Enclosure Make & Model | AKSA AUL 71/72 |
| Genset Rating | |
| Standby Power | 500 kW |
| Power Factor | 0.8 |
| Voltage Options | 480/277V, 240/120V, 208/120V, 600/347V |
| Engine Data | |
| Manufacturer | Volvo Penta |
| Model | TAD1641GE |
| Displacement & Cylinders | 16.12 L / 6 Cylinders |
| Engine Speed | 1800 rpm |
| Engine Standby Power | 546 kW |
| Engine Prime Power | 485 kW |
| Aspiration | Turbocharged |
| Compression Ratio | 16.5 : 1 |
| Bore / Stroke | 5.67 in / 6.50 in |
| Effective Mean Pressure, Standby Power | 2.3 Mpa |
| Max Combustion Pressure, Standby Power | 18.2 Mpa |
| Total Mass Moment of Inertia | 4.20 kgm2 |
| Friction Power | 53 kW |
| Wet Weight - Engine Only | 3417 lbs. |
| Wet Weight - GenPac | 4453 lbs. |
| Engine Crankcase Vent System | Open |
| Fuel System | |
| Injection Pump Type | Delphi / E1 |
| System Supply Flow | 50 g/h |
| System Return Flow | 6.6 g/h |
| Max Allowable Inlet Fuel Temp | 140 F |
| Fuel Consumption | |
| Standby Power (100%) | 35.5 gal/h |
| Standby Power (75%) | 25.9 gal/h |
| Standby Power (50%) | 17.4 gal/h |
| Standby Power (25%) | 9.9 gal/h |
| Electric System | |
| Voltage & Type | 24V, Insulated from Earth |
| Alternator Make / Output | Bosch / 80A |
| Battery Qty, Rating | 2 x 120Ah |
| Cooling System | |
| Radiator Cooling System Type | Closed Circuit |
| Fan Power Consumption | 19 kW |
| Coolant Capacity | 15.85 gal |
| Max Top Tank Temperature | 217 F |
| Thermostat, Start - Fully Open | 187-205 F |
| Exhaust System | |
| Exhaust Gas Temp | 893 F |
| Max Allowable Back Pressure | 10 kPa |
| Exhaust Gas Flow | 110.4 m3/min |
| Air Intake System | |
| Air Consumption | 45.8 m3/min |
| Max Intake Air Restriction | 5 kPa |
| Air Filter Type | Single Stage Paper Cartridge |
| Lubrication System | |
| Total System Capacity | 12.7 gal |
| Sump Capacity Max / Min | 11.1 gal / 8.5 gal |
| Max Oil Temp | 266 F |
| Oil Pressure at Rated Speed | 44-94 psi |
| Oil Consumption | 0.032 gal/h |
| Alternator Data | |
| Manufacturer | Stamford |
| Standards | BS EN 60034 |
| Control System | PMG |
| A.V.R. | MX341 |
| Voltage Regulation | +/- 1% |
| Insulation System | Class H |
| Protection | IP23 |
| Rated Power Factor | 0.8 |
| Stator Winding | Double Layer Concentric |
| Winding Pitch | Two Thirds |
| Winding Leads | 12 |
| Telephone Interference | THF < 2% |
| Waveform Distortion | No Load < 1.5% |
| Maximum Over Speed | 2250 rev/min |
| Controller Data | |
| Manufacturer | DSE |
| Model | 7320 MK II |
| Battery Charger & Electrical System Data | |
| Manufacturer | ComAp |
| Model | InteliCharger |
| Input Voltage | 85V - 264V AC |
| Output Voltage / Current | 27.2V Float / 2.5A pk |
| Jacket Water Heater Data | |
| Manufacturer | Hotstart |
| Model | CTM25210-N00 |
| Input Voltage | 240V |
| Power | 2500W |
| Enclosure Dimensions & Weight | |
| Open Skid Gen - Length | 157.5 in |
| Open Skid Gen - Width w/o lift hooks | 74.8 in |
| Open Skid Gen - Height | 75.8 in |
| Open Skid Gen - Dry Weight | 9085 lbs. |
| Level 1 Enclosure - Length | 205 in |
| Level 1 Enclosure - Width w/o lift hooks | 77 in |
| Level 1 Enclosure - Height | 89.9 in |
| Level 1 Enclosure - Dry Weight | 14030 lbs. |
| Level 1 Enclosure - Sound Pressure @ 7 meters | 79 dB(A) |
| Level 2 Enclosure - Length | 224.6 in |
| Level 2 Enclosure - Width w/o lift hooks | 77 in |
| Level 2 Enclosure - Height | 89.9 in |
| Level 2 Enclosure - Dry Weight | 14405 lbs. |
| Level 2 Enclosure - Sound Pressure @ 7 meters | 77 dB(A) |
| Fuel Tank - UL142 Listed Base Design | |
| 24hr Tank (855gal) - Dimensions L/W/H | 225 in / 74.8 in / 18 in |
| 24hr Tank (855gal) - Weight | 3200 lbs. |
| 48hr Tank (1780gal) - Dimensions L/W/H | 225 in / 74.8 in / 35 in |
| 48hr Tank (1780gal) - Weight | 4350 lbs. |
| 72hr Tank (2550gal) - Dimensions L/W/H | 300 in / 74.8 in / 36 in |
| 72hr Tank (2550gal) - Weight | 5450 lbs. |
product related documents:
| Peso | 14405 lbs |
|---|---|
| Dimensiones | 224.6 × 77 × 89.9 in |
Solo los usuarios registrados que hayan comprado este producto pueden hacer una valoración.





Valoraciones
No hay valoraciones aún.