Kohler 350KW, 3-Phase Diesel Marine Generator Open unit 350EOZCS
Kohler 350KW, 3-Phase Diesel Marine Generator Open unit 350EOZCS
Call for Price
Frequency 60 Hz
kW 350
Controller Decision-Maker(R) 3500 Controller
Fuel Type Diesel
Alternator Type 4-pole, rotating-field
Engine Manufacturer Scania
ENGINE FEATURES
Low oil pressure shutdown
High water temperature shutdown
Loss of coolant shutdown
Overcrank shutdown
Belt guard
Water cooled oil cooler
Disposable, centrifugal oil filter
Oil drain valve with skid mounted drain
GENERATOR FEATURES
Environmental Protection Agency (EPA) Tier II compliant
IMO Tier III compliant
IMO Tier II & EU Stage IIIA compliant
Permanent magnet-excited alternator
Sealed double-bearing alternator
Frame-in-frame skid design
Class H insulation with EG43 marinization treatment
Available ex factory. (Call to confirm)
350EOZCS Kohler Marine Details and Specifications
Included Accessories
- Battery (positive and negative)
- Equipment ground
- Fuel inlet and return
- Seawater inlet
- Water-cooled exhaust outlet
- Oil drain
- Customer load lead access
Siphon Break
Mandatory kit on generators installed below the waterline. Prevents the siphoning of flotation water into the engine.
Line Circuit Breaker
Protect the generator from extreme overload.
Engine Features
- Low oil pressure shutdown
- High water temperature shutdown
- Loss of coolant shutdown
- Overcrank shutdown
- Belt guard
- Water cooled oil cooler
- Disposable, centrifugal oil filter
- Oil drain valve with skid mounted drain
Alternator Features
- The generator complies with NEMA, IEEE, and ANSI standards for temperature rise.
- The alternator uses a permanent-magnet excitation system.
- The alternator has a two-thirds pitch, skewed stator.
- The generator has a solid-state, volts-per-hertz voltage regulator.
- Brushless, rotating-field alternator.
- Grey marinization treatment (EG43). Grey varnish is a high temperature insulating enamel that forms a tough and flexible film with excellent moisture and chemical protection. It is water and oil proof and also protects windings from abrasion.
- The generator sustains short-circuit current up to 300% of the rated current for up to 10 seconds
Decision-Maker® 3500 Controller
Provides advanced control, system monitoring, and system diagnostics for optimum performance and compatibility. The Decision-Maker® 3500 controller uses a patented hybrid voltage regulator and unique software logic to manage alternator thermal overload protection features normally requiring additional hardware. Additional features include:
- AC Output Voltage Regulator Adjustment. The voltage adjustment provides a maximum adjustment of ±10% of the system
- Alarm The controller can be set up to silence the alarm horn only when in the AUTO mode for NFPA-110 application or Always for user convenience.
- Alternator Protection. The controller provides generator set overload and short circuit protection matched to each alternator for the particular voltage/phase
- Automatic Restart. The controller automatic restart feature initiates the start routine and recrank after a failed start
- Cyclic The controller has programmable cyclic cranking.
- ECM The controller displays engine ECM fault code descriptions to help in engine troubleshooting.
- Engine Start The configurable starting aid feature provides customized control for an optional engine starting aid.
- Event Logging. The controller keeps a record (up to 1000 entries) for warning and shutdown faults. This fault information becomes a stored record of system events and can be
- Historical Data Total number of successful starts of the generator is recorded and displayed.
- Integrated Hybrid Voltage The voltage regulator provides ±0.5% no-load to full-load RMS voltage regulation with three-phase sensing.
- Lamp Press the alarm silence/lamp test button to verify functionality of the indicator lights.
- LCD Adjustable contrast for improving visibility.
- Measurement The controller provides selection of English or metric displays.
- Power Controller graphical display provides voltage, current, power factor, kW, kVA, and kVAR.
- Programming Access (USB). Provides software upgrades and diagnostics with PC software
- Remote Reset. The remote reset function supports acknowledging and resetting faults and allows restarting of the generator set without going to the master control switch off/reset
- Run Time The generator set run time is displayed.
- Time Delay Engine Cooldown (TDEC). The TDEC provides a time delay before the generator set shuts
- Time Delay Engine Start (TDES). The TDES provides a time delay before the generator set
- Voltage Selection This menu provides the capability to switch the generator output voltage. NOTE: Generator set output leads may require reconnection.
- Paralleling Functions:
- Bus sensing
- First on logic
- Synchronizing
- Communication based isochronous load sharing
- Droop load sharing
- External controlled load sharing via analog bias signals
Product Specifications:
Generator model | 350EOZCS |
Engine model | DI13-75M |
Displacement (L) | 12.7 (775) |
Cyl. qty. | 6, inline |
Governor | Electronically controlled |
Type | 4-cycle |
DC Voltage | 24 |
3Ph Alternator model | ECO40-3S |
AC Voltage | 120/208 |
Hz | 60 |
Amps @ 25° C (77° F) | 1600 |
Continuous Power @ 25° C (77° F) | 350kW / 438KVA |
Fuel Consumption Diesel, 60Hz Lph (gph) at % load | |
100% | 90.1 (23.8) |
75% | 67.4 (17.8) |
50% | 46.9 (12.4) |
25% | 28.8 (7.6) |
PRODUCT Related documents:
Peso | 7035 lbs |
---|---|
Dimensiones | 109.6 × 51.0 × 51.5 in |