Blue Star PD125-01 (125kWe)

Share this product!

Blue Star PD125-01 (125kWe)

SKU: PD125-01

Blue Star Power Systems 125 kWe Diesel Standby Generator — a robust, EPA Tier 3 certified power solution featuring a Perkins 1106D-E70TAG2 engine, Stamford alternator, and a sound-attenuated Level 2 enclosure rated for 200 MPH winds, designed for commercial and industrial standby applications. 

 

  • 125 kWe standby output at 60 Hz / 1800 RPM, available in 120/240V single phase or 277/480V three phase configurations 
  • Powered by Perkins 1106D-E70TAG2 six-cylinder, turbocharged, air charge-cooled diesel engine with electronic isochronous governor 
  • Stamford UCI274E brushless single-bearing alternator with AS440 Automatic Voltage Regulator providing ±1% voltage regulation 
  • Level 2 weather-proof enclosure: 14-gauge powder-coated steel, 200 MPH wind rated (IBC 2021), pitched roof, with 1.5″ Type D sound attenuation foam 
  • Blue Star DCP7310 microprocessor-based digital control panel with CAN Bus J1939, RS485, event logging, and NFPA 110 Level 1 compatibility 
  • UL 2200 listed, CSA approved, EPA Tier 3 certified, seismic certified to IBC 2021, and NFPA 110 / CSA C282 compliant 
  • 200 Amp, 3-pole, 600V mainline circuit breaker mounted and wired in a NEMA 1 enclosure 
  • 24-hour, 250-gallon UL 142 listed double-wall sub-base fuel tank standard; 48-hour (500 gal) and 72-hour (750 gal) options available 
  • Jacket water block heater rated at 2000W / 240VAC for cold-weather starts down to -20°F, with isolation valves 
  • Factory load tested including block loading to rated kWe and PF; 2-year / 2,000-hour standby limited warranty 
This product require a prior technical study of your needs in order to offer you a price. Please click on "Request a quote".
 
Share:
Description
Additional Info
Reviews
Description

 

PD125-01 product details and specifications:

General Overview 

  • Model: PD125-01 — Blue Star Power Systems Diesel Product Line 
  • Power Rating: 125 kWe Standby 
  • Application: Emergency Stationary Standby 
  • Fuel: Diesel 
  • Frequency: 60 Hz 
  • Speed: 1800 RPM 
  • Voltage Options: 120/240V Single Phase or 277/480V Three Phase 
  • Power Factor: 0.8 (three phase) / 1.0 (single phase 240V) 
  • Unit Color: White 

Certifications & Compliance 

  • UL 2200 & cUL Listed 
  • CSA Approved 
  • EPA Tier 3 Certified 
  • Seismic Certified to IBC 2021 
  • NFPA 110 / CSA C282 Compliant 
  • Made in USA 

Engine 

  • Manufacturer: Perkins 
  • Model: 1106D-E70TAG2 
  • Type: 4-Cycle, Turbocharged, Air Charge Cooled (CAC) 
  • Cylinder Arrangement: 6 Cylinder Inline 
  • Displacement: 428 Cu. In. (7.01 L) 
  • Bore x Stroke: 4.13 in. x 5.31 in. (105 mm x 135 mm) 
  • Compression Ratio: 16.8:1 
  • Rated RPM: 1800 
  • Max HP Standby: 229 HP (171 kWm) 
  • Governor: Electronic Isochronous 
  • Combustion System: Direct Injection Diesel 

Alternator 

  • Model: Stamford UCI274E 
  • Type: Brushless Single Bearing 
  • Leads: 12 Lead Wired 
  • 480V Connection: 12 Lead High Wye 
  • 240V Three Phase Connection: 12 Lead Delta 
  • 208V Connection: 12 Lead Wye 
  • 600V Connection: 4 Lead Wye 
  • Temperature Rise: 125°C Standby over 40°C Ambient 
  • Insulation: Class H 
  • Poles: 4 Pole, Rotating Field 
  • Load Step: 100% of Rated Load in One Step 
  • Maximum Harmonic Content: 5% 
  • Standards: NEMA MG1, IEEE, ANSI 

Voltage Regulator 

  • Model: Stamford AS440 Automatic Voltage Regulator 
  • Regulation: ±1% 
  • Type: Half-wave phase controlled thyristor AVR 
  • Sensing Input: 190–264VAC, 1-phase, 50–60 Hz 
  • External Voltage Adjustment: ±10% with 1k ohm trimmer 
  • Soft Start Ramp Time: 3 seconds 
  • Over Excitation Protection Set Point: 65VDC 

Control Panel 

  • Model: Blue Star DCP7310 Microprocessor Based Gen-Set Controller 
  • Mounted: Facing left from generator end (unless specified otherwise) 
  • Display: 4-Line back-lit LCD with five-key menu navigation 
  • Standard Shutdowns: Low Oil Pressure, High Coolant Temp, Overspeed, Overcrank 
  • Standard Alarms: Emergency Stop Pushbutton, Audible Alarm Buzzer with Silencing Switch 
  • Communication: CAN Bus (J1939) ECU, RS485 Communicator Interface 
  • Event Log: 250 events 
  • Inputs/Outputs: 8 programmable contact inputs, 10 contact outputs 
  • Rating: IP65 (with supplied gasket), cULus Listed, CE Approved 
  • NFPA Compatibility: NFPA 110 Level 1 Compatible 

Enclosure (Level 2 — Standard) 

  • Type: Weather Proof with Foam 
  • Material: 14 Gauge Powder Coated Steel 
  • Wind Rating: 200 MPH — IBC 2021 / ASCE/SEI 7-16 Certified 
  • Roof: Pitched for increased structural integrity and improved watershed 
  • Intake/Exhaust: Punched intake with baffle and punched exhaust openings 
  • Doors: Keyed Alike Lockable with Draw Down Latches and Stainless Steel Hinges 
  • Sound Attenuation: 1.5" Polydamp Type D Acoustical Foam (PAF) installed 
  • Base: Formed Steel with mounting and lifting holes 
  • Vibration Isolation: Vibration mounts to isolate unit from base rail 

Dimensions & Weight 

  • OPU: 110 x 54 x 65 in. — 3,700 lbs. 
  • Level 1 Enclosure: 130 x 54 x 82 in. — 4,600 lbs. 
  • Level 2 Enclosure: 130 x 54 x 82 in. — 4,650 lbs. 
  • Level 3 Enclosure: 164 x 54 x 74 in. — 4,875 lbs. 
  • Note: Allow 6–12 inches for height of exhaust stack 

Sound Data 

  • OPU: No Load 82 dBA / Full Load 85 dBA 
  • Level 1: No Load 80 dBA / Full Load 82 dBA 
  • Level 2: No Load 75 dBA / Full Load 78 dBA 
  • Level 3: No Load 71 dBA / Full Load 73 dBA 
  • Measurement: At 23 feet (7 meters) per ISO 8528-10 

Cooling System 

  • Type: Unit Mounted Radiator, 50°C (122°F) Ambient Rated 
  • Water Pump Flow Rate: 44.9 GPM (170 lit/min) 
  • Heat Rejection to Coolant: 4,280 BTUM (74.9 kW) 
  • Heat Rejection to CAC: 1,857 BTUM (32.5 kW) 
  • Heat Radiated to Ambient: 2,572 BTUM (45.0 kW) 
  • Max Allowable Static Pressure on Rad. Exhaust: 0.50 in. H₂O (0.12 kPa) 

Exhaust System 

  • Exhaust Gas Temperature at Stack: 842°F (450°C) 
  • Gas Volume at Stack Temp: 1,057 CFM (29.9 m³/min) 
  • Max Allowable Exhaust Restriction: 60.0 in. H₂O (15.0 kPa) 
  • Silencer: Critical Grade Compact CPJ Series Silencer Mounted to Engine 

Air Requirements 

  • Aspirating Air Flow: 509 CFM (14.4 m³/min) 
  • Air Flow Required for Radiator Cooled Unit: 7,173 CFM (203 m³/min) 
  • Air Cleaner: Dry Single Stage 
  • Air Restriction Indicator: Installed in air filtration system 

Fuel System 

  • Fuel Consumption at 100% Load: 9.58 gal/hr (36.3 lit/hr) 
  • Fuel Consumption at 75% Load: 7.87 gal/hr (29.8 lit/hr) 
  • Fuel Consumption at 50% Load: 5.62 gal/hr (21.3 lit/hr) 
  • Flexible Fuel Connector Included 

Sub-Base Fuel Tank Options 

  • 24-Hour Tank: 250 Gallon — UL 142 Listed, Double Wall Secondary Containment with Stub-up Area 
  • 48-Hour Tank: 500 Gallon — UL 142 Listed, Double Wall Secondary Containment 
  • 72-Hour Tank: 750 Gallon — UL 142 Listed, Double Wall Secondary Containment 
  • Includes: Supply & Return Connections, Fuel Level Gauge, Fuel Leak Switch, Fill & Vent Plumbing 

Fluids Capacity 

  • Total Oil System: 4.62 gal (17.5 lit) 
  • Engine Jacket Water: 2.51 gal (9.50 lit) 
  • System Coolant Capacity: 5.55 gal (21.0 lit) 

Electrical & Accessories 

  • Battery: 12 Volt System with Rack and Cables 
  • Battery Charger: 12 Volt 6 Amp, Mounted and Wired to Terminal 
  • Jacket Water Heater: 2000W 240VAC, Rated for -20°F, Installed with Isolation Valves and Wired to Terminal 
  • Mainline Breaker: 200 Amp 3 Pole 600 Volt Breaker Mounted and Wired in NEMA 1 Enclosure 
  • Oil Drain Extension: Plumbed to Bulkhead Fitting in Base 

Factory Test & Warranty 

  • Factory Test: Standard Commercial Testing — Alarm Shutdowns, Voltage Settings, Block Load to Rated kWe and PF 
  • Warranty: 2 Year / 2,000 Hour Standby Limited Warranty 
  • All units built and tested to cUL, CSA and NFPA 110 standards 

product specifications:

SpecificationValue
GENERAL
ModelPD125-01
Power Rating125 kWe Standby
Frequency60 Hz
Speed1800 RPM
Voltage Options120/240V Single Phase or 277/480V Three Phase
Power Factor0.8 (three phase) / 1.0 (single phase)
Fuel TypeDiesel
ApplicationEmergency Stationary Standby
UL ListedUL 2200 & cUL Listed
CSA ApprovedYes
EPA CertificationTier 3
Seismic CertificationIBC 2021
NFPA ComplianceNFPA 110 / CSA C282
WARRANTY
Warranty2 Year / 2,000 Hour Standby Limited
ENGINE
Engine ManufacturerPerkins
Engine Model1106D-E70TAG2
Engine Type4-Cycle, Turbocharged, Air Charge Cooled (CAC)
Cylinder Arrangement6 Cylinder Inline
Displacement428 Cu. In. (7.01 L)
Bore x Stroke4.13 in. x 5.31 in. (105 mm x 135 mm)
Compression Ratio16.8:1
Rated RPM1800
Max HP Standby229 HP (171 kWm)
GovernorElectronic Isochronous
ALTERNATOR
Alternator ModelStamford UCI274E
Alternator TypeBrushless Single Bearing
Winding Leads12 Lead
Connection (480V)12 Lead Wye
Connection (240V 3Ph)12 Lead Delta
Connection (208V)12 Lead Wye
Connection (600V)4 Lead Wye
Temperature Rise125°C Standby / 40°C Ambient
Insulation ClassClass H
Voltage RegulatorStamford AS440 Automatic Voltage Regulator
Voltage Regulation±1%
Harmonic Content5% Maximum
StandardsNEMA MG1, IEEE, ANSI
CONTROL PANEL
Control Panel ModelBlue Star DCP7310 Microprocessor Based
CommunicationCAN Bus (J1939) / RS485
Display4-Line Back-lit LCD
Standard ShutdownsLow Oil Pressure, High Coolant Temp, Overspeed, Overcrank
AlarmsEmergency Stop Pushbutton, Audible Alarm Buzzer with Silencing Switch
NFPA CompatibilityNFPA 110 Level 1 Compatible
ENCLOSURE
Enclosure LevelLevel 2 (Weather Proof with Foam)
Enclosure Material14 Gauge Powder Coated Steel
Wind Rating200 MPH (IBC 2021, ASCE/SEI 7-16)
Roof DesignPitched Roof
Sound Attenuation1.5" Polydamp Type D Acoustical Foam (PAF)
DoorsKeyed Alike Lockable with Draw Down Latches and Stainless Steel Hinges
BaseFormed Steel with Mounting and Lifting Holes
Vibration IsolationVibration Mounts Installed
Unit ColorWhite
DIMENSIONS & WEIGHT (Level 2)
Length130 in.
Width54 in.
Height82 in.
Weight4,650 lbs.
SOUND DATA (Level 2)
Sound Level - No Load75 dBA @ 23 ft (7 m)
Sound Level - Full Load78 dBA @ 23 ft (7 m)
COOLING SYSTEM
Cooling TypeUnit Mounted Radiator
Ambient Capacity50°C (122°F)
Water Pump Flow Rate44.9 GPM (170 lit/min)
Heat Rejection to Coolant4,280 BTUM (74.9 kW)
Heat Rejection to CAC1,857 BTUM (32.5 kW)
Heat Radiated to Ambient2,572 BTUM (45.0 kW)
EXHAUST SYSTEM
Exhaust Gas Temperature842°F (450°C) at Stack
Gas Volume at Stack Temp1,057 CFM (29.9 m³/min)
Max Allowable Restriction60.0 in. H₂O (15.0 kPa)
SilencerCritical Grade Compact (CPJ Series) Mounted to Engine
AIR REQUIREMENTS
Aspirating Air Flow509 CFM (14.4 m³/min)
Air Flow for Rad. Cooled7,173 CFM (203 m³/min)
Air CleanerDry Single Stage
FUEL SYSTEM
Fuel Consumption @ 100%9.58 gal/hr (36.3 lit/hr)
Fuel Consumption @ 75%7.87 gal/hr (29.8 lit/hr)
Fuel Consumption @ 50%5.62 gal/hr (21.3 lit/hr)
Fuel Tank - Standard24 Hour / 250 Gallon UL 142 Listed Sub-Base
Fuel Tank - Option 148 Hour / 500 Gallon Sub-Base
Fuel Tank - Option 272 Hour / 750 Gallon Sub-Base
Fuel Tank ConstructionDouble Wall with Secondary Containment
FLUIDS CAPACITY
Total Oil System4.62 gal (17.5 lit)
Engine Jacket Water2.51 gal (9.50 lit)
System Coolant Capacity5.55 gal (21.0 lit)
ELECTRICAL
Battery System12 Volt with Rack and Cables
Battery Charger12 Volt 6 Amp, Mounted and Wired
Jacket Water Heater2000W 240VAC, Rated for -20°F, with Isolation Valves
Mainline Breaker200 Amp 3 Pole 600 Volt, NEMA 1 Enclosure
Oil Drain ExtensionPlumbed to Bulkhead Fitting in Base
FACTORY TEST
Factory TestStandard Commercial Testing: Alarm Shutdowns, Voltage Settings, Block Load to Rated kWe and PF

 

product related documents:

2026 EPA Cert_TPKXL07.0PW1-002 PD125-01, PD150-01.pdf

PD125-01_Drawings.pdf

PD125-01_SpecSheet.pdf

PD125-01 Engine Data Sheet 12-5-23.pdf

PD125-01.pdf

Additional Info
Weight4650 lbs
Dimensions130 × 54 × 82 in
Reviews

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Item added to cart View Cart Checkout
Item added to wishlist View Wishlist
Item removed from wishlist