Blue Star Power Systems 150 kWe Diesel Standby Generator — a rugged, UL 2200 Listed industrial generator set powered by a John Deere engine, designed for emergency stationary standby applications with multi-voltage capability and sound-attenuated enclosure options.
- 150 kWe standby power rating at 1800 RPM, 60 Hz, available in 208–600 Volt configurations
- Powered by John Deere 6068HF285 6-cylinder inline, 4-cycle, turbocharged engine with electronic isochronous governor
- Stamford UCI274F brushless single-bearing alternator with Stamford AS440 Automatic Voltage Regulator (±1% regulation)
- Blue Star DCP7310 microprocessor-based digital control panel with NFPA 110 Level 1 compatibility
- Level 2 weather-proof enclosure with 1.5″ Polydamp Type D acoustical foam, 200 MPH wind-rated powder-coated 14-gauge steel
- Unit-mounted radiator cooled for 50°C ambient with vibration isolation mounts
- 225 Amp 3-pole 600V main line circuit breaker, 12V battery charger (6A), and 2000W jacket water heater rated for -20°F
- 24-hour / 375-gallon UL 142 listed double-wall sub-base fuel tank with secondary containment (48 hr and 72 hr options available)
- Critical grade CPJ series silencer, dry single-stage air cleaner, and flexible fuel connector included
- UL 2200 & cUL Listed, CSA Certified, EPA Tier 3, Seismic Certified to IBC 2021, NFPA 110 / CSA C282 compliant
- 2 Year / 2000 Hour standby limited warranty with standard commercial factory load testing
JD150-01 product details and specifications:
Engine
General
- Manufacturer: John Deere
- Model: 6068HF285
- Type: 4-Cycle, 6-Cylinder Inline
- Aspiration: Turbocharged with Charge Air Cooling (CAC)
- Displacement: 415 cu. in. (6.80 L)
- Bore x Stroke: 4.19 in. (10.6 cm) x 5.00 in. (12.7 cm)
- Compression Ratio: 19.0:1
- Rated RPM: 1800
- Max HP Standby: 237 HP (177 kWm)
- Governor: Electronic Isochronous
Exhaust System
- Gas Temperature at Stack: 981°F (527°C)
- Gas Volume at Stack Temp: 1,158 CFM (32.8 m³/min)
- Maximum Allowable Exhaust Restriction: 30.0 in. H2O (7.50 kPa)
Cooling System
- Radiator Ambient Capacity: 122°F (50°C)
- Maximum Allowable Static Pressure on Radiator Exhaust: 0.50 in. H2O (0.12 kPa)
- Water Pump Flow Rate: 48.0 GPM (182 lit/min)
- Heat Rejection to Coolant: 5,407 BTUM (94.6 kW)
- Heat Rejection to CAC: 1,708 BTUM (29.9 kW)
- Heat Radiated to Ambient: 3,021 BTUM (52.9 kW)
Air Requirements
- Aspirating: 448 CFM (12.7 m³/min)
- Air Flow Required for Radiator-Cooled Unit: 10,683 CFM (302 m³/min)
Fuel Consumption
- At 100% Power Rating: 11.1 gal/hr (42.0 lit/hr)
- At 75% Power Rating: 8.95 gal/hr (33.9 lit/hr)
- At 50% Power Rating: 6.72 gal/hr (25.4 lit/hr)
Fluids Capacity
- Total Oil System: 5.02 gal (19.0 lit)
- Engine Jacket Water Capacity: 3.14 gal (11.9 lit)
- System Coolant Capacity: 6.10 gal (23.1 lit)
Generator (Alternator)
- Manufacturer: Stamford
- Model (480V, 3Ph): UCI274F — 12 Lead Wye
- Model (600V, 3Ph): UCI274F — 4 Lead Wye
- Model (208V, 3Ph): UCI274G — 12 Lead Wye
- Model (240V, 3Ph): UCI274G — 12 Lead Delta
- Model (240V, 1Ph): UCDI274J1 — 12 Lead DD
- Type: Brushless, Single Bearing
- Voltage Regulator: Stamford AS440 Automatic Voltage Regulator
- Voltage Regulation: ±1%
- Poles: 4 Pole, Rotating Field
- Standby Temperature Rise: 125°C Rise Over 40°C Ambient
- One-Step Load Pick-up: 100% of Rated Load
- Maximum Harmonic Content: 5%
- Standards: NEMA MG 1, IEEE and ANSI
- Insulation Class: Class H
- Protection: IP23
- Rated Power Factor: 0.8
Voltage Ratings
- 240V Single Phase: 150 kWe, 625 Amps, PF 1.0
- 208V Three Phase: 150 kWe, 521 Amps, PF 0.8
- 240V Three Phase: 150 kWe, 452 Amps, PF 0.8
- 480V Three Phase: 150 kWe, 226 Amps, PF 0.8
- 600V Three Phase: 150 kWe, 181 Amps, PF 0.8
- All configurations: 60 Hz, 125°C/40°C Temperature Rise
Control Panel — Blue Star DCP7310
Standard Features
- Microprocessor-based digital control panel
- Mounted in NEMA 12 Enclosure
- NFPA 110 Level 1 Compatible
- Digital metering: kW, kVA, kVAr, kWh, frequency, voltage, amperage
- CAN Bus (J1939) ECU Communications
- Windows-based configuration software
- Multilingual capability
- 8 programmable contact inputs, 10 contact outputs
- RS485 communicator interface
- Event recording (250 events)
- IP65 rating with supplied gasket
- cULus Listed, CE Approved
Engine Protection — Pre-Alarms
- Low Oil Pressure
- High Coolant Temperature
- Low Coolant Temperature
- Battery Overcharge (High Voltage)
- Weak Battery (Low Voltage)
- Low Fuel Level
- Fuel Leak Detect
- Engine kWe Overload
- Maintenance Interval Timer
Engine Protection — Shutdowns
- Low Oil Pressure
- High Coolant Temperature
- Overspeed
- Overcrank
- Emergency Stop Pushbutton
Generator Protection
- Undervoltage (27)
- Overvoltage (59)
- Underfrequency (81U)
- Overfrequency (81O)
- Overcurrent (51)
- Reverse Power (32)
- Loss of Excitation (40Q)
- Phase Imbalance (47)
Enclosure
- Level 2 — Weather Proof with Sound Attenuation Foam
- Material: Powder Coated 14 Gauge Steel
- Wind Rating: 200 MPH — Certified per IBC 2021 and ASCE/SEI 7-16
- Roof: Pitched for structural integrity and watershed
- Sound Attenuation: 1.5" Polydamp Type D Acoustical Foam (PAF)
- Doors: Keyed alike lockable with draw down latches and stainless steel hinges
- Intake: Punched with baffle; Exhaust: Punched openings
- Base: Formed steel with mounting and lifting holes
- Vibration isolation mounts included
- Sound Level (Level 2, No Load): 75 dBA; Full Load: 78 dBA
Enclosure Dimensions (Level 2)
- Length x Width x Height: 130 in. x 54 in. x 74 in.
- Weight: 4,425 lbs.
Fuel Tank
- Type: UL 142 Listed Sub-Base, Double Wall with Secondary Containment
- Standard: 24 Hour / 375 Gallon
- Optional: 48 Hour / 750 Gallon
- Optional: 72 Hour / 1,125 Gallon
- Features: Supply & Return Connections, Fuel Level Gauge, Fuel Leak Switch, Fill & Vent Plumbing
- Construction: Heavy gauge steel, electrical stub-up area standard
Additional Standard Equipment
- Main Line Circuit Breaker: 225 Amp, 3 Pole, 600 Volt, Mounted & Wired in NEMA 1 Enclosure
- Battery Charger: 12 Volt, 6 Amp, Mounted and Wired to Terminal
- Jacket Water Heater: 2000W, 240VAC, Rated for -20°F, with Isolation Valves and Wired to Terminal
- Oil Drain Extension: Plumbed to Bulkhead Fitting in Base
- Air Cleaner: Dry Single Stage
- Silencer: Critical Grade Compact CPJ Series, Mounted to Engine
- Battery: 12 Volt System with Rack and Cables
- Flexible Fuel Connector
- Vibration Isolation Mounts
- Single Source Supplier
Sound Data
- OPU: 82 dBA (No Load) / 85 dBA (Full Load)
- Level 1: 80 dBA (No Load) / 82 dBA (Full Load)
- Level 2: 75 dBA (No Load) / 78 dBA (Full Load)
- Level 3: 71 dBA (No Load) / 73 dBA (Full Load)
- Sound data measured at 23 feet (7 meters) per ISO 8528-10
Factory Testing
- Verification of alarm shutdowns and voltage settings
- Block loading to rated kWe and power factor
- No load and max load tests at 1.0 PF and 0.8 PF
- Block loads at 0–25%, 0–50%, 0–75%, 0–100% of rated load
- Test metering accuracy: 1.3% or better, NIST traceable
- All procedures per MIL-STD-705C where applicable
product specifications:
| Specification | Value |
| Model | JD150-01 |
| kWe Rating (Standby) | 150 kWe |
| Frequency | 60 Hz |
| Speed | 1800 RPM |
| Voltage Options | 120/240V Single Phase; 208/240/480/600V Three Phase |
| Power Factor | 0.8 (Three Phase) / 1.0 (Single Phase 240V) |
| Fuel Type | Diesel |
| EPA Certification | Tier 3 |
| UL Listed | UL 2200 & cUL Listed |
| CSA Certified | Yes |
| Seismic Certification | IBC 2021 |
| NFPA Compliance | NFPA 110 / CSA C282 |
| Paint Color | White (standard); Gray available |
| ENGINE | |
| Engine Manufacturer | John Deere |
| Engine Model | 6068HF285 |
| Engine Type | 4-Cycle, 6-Cylinder Inline |
| Aspiration | Turbocharged with Charge Air Cooling (CAC) |
| Displacement | 415 cu. in. (6.80 L) |
| Bore x Stroke | 4.19 in. x 5.00 in. |
| Compression Ratio | 19.0:1 |
| Rated RPM | 1800 |
| Max Standby HP | 237 HP (177 kWm) |
| Governor | Electronic Isochronous |
| Air Cleaner | Dry Single Stage |
| Silencer | Critical Grade Compact (CPJ Series), Mounted to Engine |
| Battery | 12 Volt System with Rack and Cables |
| GENERATOR (ALTERNATOR) | |
| Generator Manufacturer | Stamford |
| Generator Model (480V) | UCI274F — 12 Lead Wye |
| Generator Model (208/240V 3Ph) | UCI274G — 12 Lead Wye / Delta |
| Generator Model (240V 1Ph) | UCDI274J1 — 12 Lead DD |
| Generator Type | Brushless, Single Bearing |
| Voltage Regulator | Stamford AS440 Automatic Voltage Regulator |
| Voltage Regulation | ±1% |
| Poles | 4 Pole, Rotating Field |
| Standby Temp Rise | 125°C Rise Over 40°C Ambient |
| Harmonic Content | 5% Maximum |
| Standards | NEMA MG 1, IEEE and ANSI |
| CONTROL PANEL | |
| Control Panel Model | Blue Star DCP7310 Microprocessor Based Gen-Set Controller |
| Control Panel Enclosure | NEMA 12 |
| NFPA 110 Compatibility | Level 1 Compatible |
| Standard Shutdowns | Low Oil Pressure, High Coolant Temp, Overspeed, Overcrank |
| Alarm Features | Emergency Stop Pushbutton, Audible Alarm Buzzer with Silencing Switch |
| ENCLOSURE | |
| Enclosure Level | Level 2 — Weather Proof with Foam |
| Enclosure Material | Powder Coated 14 Gauge Steel |
| Wind Rating | 200 MPH (Rated per IBC 2021 / ASCE/SEI 7-16) |
| Roof Design | Pitched Roof |
| Sound Attenuation | 1.5" Polydamp Type D Acoustical Foam (PAF) |
| Doors | Keyed Alike Lockable with Draw Down Latches and Stainless Steel Hinges |
| Base | Formed Steel with Mounting and Lifting Holes |
| Vibration Isolation | Included |
| COOLING SYSTEM | |
| Cooling Type | Unit Mounted Radiator |
| Ambient Capacity | 50°C (122°F) |
| Water Pump Flow Rate | 48.0 GPM (182 lit/min) |
| Heat Rejection to Coolant | 5,407 BTUM (94.6 kW) |
| FUEL SYSTEM | |
| Fuel Tank Capacity | 375 Gallon (24 Hour) |
| Fuel Tank Listing | UL 142 Listed Sub-Base, Double Wall, Secondary Containment |
| Fuel Consumption at 100% | 11.1 gal/hr |
| Fuel Consumption at 75% | 8.95 gal/hr |
| Fuel Consumption at 50% | 6.72 gal/hr |
| ELECTRICAL ACCESSORIES | |
| Mainline Breaker | 225 Amp, 3 Pole, 600 Volt (NEMA 1 Enclosure) |
| Battery Charger | 12 Volt, 6 Amp, Mounted and Wired to Terminal |
| Jacket Water Heater | 2000W, 240VAC, Rated for -20°F, with Isolation Valves |
| EXHAUST SYSTEM | |
| Exhaust Gas Temp (Stack) | 981°F (527°C) |
| Gas Volume at Stack Temp | 1,158 CFM (32.8 m³/min) |
| Max Exhaust Restriction | 30.0 in. H2O (7.50 kPa) |
| WARRANTY & TESTING | |
| Warranty | 2 Year / 2000 Hour Limited |
| Factory Test | Standard Commercial Testing — Block Loading to Rated kWe and PF |