Blue Star JD150-01 (150kWe)

Share this product!

Blue Star JD150-01 (150kWe)

SKU: JD150-01

Blue Star Power Systems 150 kWe Diesel Standby Generator — a rugged, UL 2200 Listed industrial generator set powered by a John Deere engine, designed for emergency stationary standby applications with multi-voltage capability and sound-attenuated enclosure options. 

 

  • 150 kWe standby power rating at 1800 RPM, 60 Hz, available in 208–600 Volt configurations 
  • Powered by John Deere 6068HF285 6-cylinder inline, 4-cycle, turbocharged engine with electronic isochronous governor 
  • Stamford UCI274F brushless single-bearing alternator with Stamford AS440 Automatic Voltage Regulator (±1% regulation) 
  • Blue Star DCP7310 microprocessor-based digital control panel with NFPA 110 Level 1 compatibility 
  • Level 2 weather-proof enclosure with 1.5″ Polydamp Type D acoustical foam, 200 MPH wind-rated powder-coated 14-gauge steel 
  • Unit-mounted radiator cooled for 50°C ambient with vibration isolation mounts 
  • 225 Amp 3-pole 600V main line circuit breaker, 12V battery charger (6A), and 2000W jacket water heater rated for -20°F 
  • 24-hour / 375-gallon UL 142 listed double-wall sub-base fuel tank with secondary containment (48 hr and 72 hr options available) 
  • Critical grade CPJ series silencer, dry single-stage air cleaner, and flexible fuel connector included 
  • UL 2200 & cUL Listed, CSA Certified, EPA Tier 3, Seismic Certified to IBC 2021, NFPA 110 / CSA C282 compliant 
  • 2 Year / 2000 Hour standby limited warranty with standard commercial factory load testing 
This product require a prior technical study of your needs in order to offer you a price. Please click on "Request a quote".
 
Share:
Description
Additional Info
Reviews
Description

 

JD150-01 product details and specifications:

Engine 

General 

  • Manufacturer: John Deere 
  • Model: 6068HF285 
  • Type: 4-Cycle, 6-Cylinder Inline 
  • Aspiration: Turbocharged with Charge Air Cooling (CAC) 
  • Displacement: 415 cu. in. (6.80 L) 
  • Bore x Stroke: 4.19 in. (10.6 cm) x 5.00 in. (12.7 cm) 
  • Compression Ratio: 19.0:1 
  • Rated RPM: 1800 
  • Max HP Standby: 237 HP (177 kWm) 
  • Governor: Electronic Isochronous 

Exhaust System 

  • Gas Temperature at Stack: 981°F (527°C) 
  • Gas Volume at Stack Temp: 1,158 CFM (32.8 m³/min) 
  • Maximum Allowable Exhaust Restriction: 30.0 in. H2O (7.50 kPa) 

Cooling System 

  • Radiator Ambient Capacity: 122°F (50°C) 
  • Maximum Allowable Static Pressure on Radiator Exhaust: 0.50 in. H2O (0.12 kPa) 
  • Water Pump Flow Rate: 48.0 GPM (182 lit/min) 
  • Heat Rejection to Coolant: 5,407 BTUM (94.6 kW) 
  • Heat Rejection to CAC: 1,708 BTUM (29.9 kW) 
  • Heat Radiated to Ambient: 3,021 BTUM (52.9 kW) 

Air Requirements 

  • Aspirating: 448 CFM (12.7 m³/min) 
  • Air Flow Required for Radiator-Cooled Unit: 10,683 CFM (302 m³/min) 

Fuel Consumption 

  • At 100% Power Rating: 11.1 gal/hr (42.0 lit/hr) 
  • At 75% Power Rating: 8.95 gal/hr (33.9 lit/hr) 
  • At 50% Power Rating: 6.72 gal/hr (25.4 lit/hr) 

Fluids Capacity 

  • Total Oil System: 5.02 gal (19.0 lit) 
  • Engine Jacket Water Capacity: 3.14 gal (11.9 lit) 
  • System Coolant Capacity: 6.10 gal (23.1 lit) 

Generator (Alternator) 

  • Manufacturer: Stamford 
  • Model (480V, 3Ph): UCI274F — 12 Lead Wye 
  • Model (600V, 3Ph): UCI274F — 4 Lead Wye 
  • Model (208V, 3Ph): UCI274G — 12 Lead Wye 
  • Model (240V, 3Ph): UCI274G — 12 Lead Delta 
  • Model (240V, 1Ph): UCDI274J1 — 12 Lead DD 
  • Type: Brushless, Single Bearing 
  • Voltage Regulator: Stamford AS440 Automatic Voltage Regulator 
  • Voltage Regulation: ±1% 
  • Poles: 4 Pole, Rotating Field 
  • Standby Temperature Rise: 125°C Rise Over 40°C Ambient 
  • One-Step Load Pick-up: 100% of Rated Load 
  • Maximum Harmonic Content: 5% 
  • Standards: NEMA MG 1, IEEE and ANSI 
  • Insulation Class: Class H 
  • Protection: IP23 
  • Rated Power Factor: 0.8 

Voltage Ratings 

  • 240V Single Phase: 150 kWe, 625 Amps, PF 1.0 
  • 208V Three Phase: 150 kWe, 521 Amps, PF 0.8 
  • 240V Three Phase: 150 kWe, 452 Amps, PF 0.8 
  • 480V Three Phase: 150 kWe, 226 Amps, PF 0.8 
  • 600V Three Phase: 150 kWe, 181 Amps, PF 0.8 
  • All configurations: 60 Hz, 125°C/40°C Temperature Rise 

Control Panel — Blue Star DCP7310 

Standard Features 

  • Microprocessor-based digital control panel 
  • Mounted in NEMA 12 Enclosure 
  • NFPA 110 Level 1 Compatible 
  • Digital metering: kW, kVA, kVAr, kWh, frequency, voltage, amperage 
  • CAN Bus (J1939) ECU Communications 
  • Windows-based configuration software 
  • Multilingual capability 
  • 8 programmable contact inputs, 10 contact outputs 
  • RS485 communicator interface 
  • Event recording (250 events) 
  • IP65 rating with supplied gasket 
  • cULus Listed, CE Approved 

Engine Protection — Pre-Alarms 

  • Low Oil Pressure 
  • High Coolant Temperature 
  • Low Coolant Temperature 
  • Battery Overcharge (High Voltage) 
  • Weak Battery (Low Voltage) 
  • Low Fuel Level 
  • Fuel Leak Detect 
  • Engine kWe Overload 
  • Maintenance Interval Timer 

Engine Protection — Shutdowns 

  • Low Oil Pressure 
  • High Coolant Temperature 
  • Overspeed 
  • Overcrank 
  • Emergency Stop Pushbutton 

Generator Protection 

  • Undervoltage (27) 
  • Overvoltage (59) 
  • Underfrequency (81U) 
  • Overfrequency (81O) 
  • Overcurrent (51) 
  • Reverse Power (32) 
  • Loss of Excitation (40Q) 
  • Phase Imbalance (47) 

Enclosure 

  • Level 2 — Weather Proof with Sound Attenuation Foam 
  • Material: Powder Coated 14 Gauge Steel 
  • Wind Rating: 200 MPH — Certified per IBC 2021 and ASCE/SEI 7-16 
  • Roof: Pitched for structural integrity and watershed 
  • Sound Attenuation: 1.5" Polydamp Type D Acoustical Foam (PAF) 
  • Doors: Keyed alike lockable with draw down latches and stainless steel hinges 
  • Intake: Punched with baffle; Exhaust: Punched openings 
  • Base: Formed steel with mounting and lifting holes 
  • Vibration isolation mounts included 
  • Sound Level (Level 2, No Load): 75 dBA; Full Load: 78 dBA 

Enclosure Dimensions (Level 2) 

  • Length x Width x Height: 130 in. x 54 in. x 74 in. 
  • Weight: 4,425 lbs. 

Fuel Tank 

  • Type: UL 142 Listed Sub-Base, Double Wall with Secondary Containment 
  • Standard: 24 Hour / 375 Gallon 
  • Optional: 48 Hour / 750 Gallon 
  • Optional: 72 Hour / 1,125 Gallon 
  • Features: Supply & Return Connections, Fuel Level Gauge, Fuel Leak Switch, Fill & Vent Plumbing 
  • Construction: Heavy gauge steel, electrical stub-up area standard 

Additional Standard Equipment 

  • Main Line Circuit Breaker: 225 Amp, 3 Pole, 600 Volt, Mounted & Wired in NEMA 1 Enclosure 
  • Battery Charger: 12 Volt, 6 Amp, Mounted and Wired to Terminal 
  • Jacket Water Heater: 2000W, 240VAC, Rated for -20°F, with Isolation Valves and Wired to Terminal 
  • Oil Drain Extension: Plumbed to Bulkhead Fitting in Base 
  • Air Cleaner: Dry Single Stage 
  • Silencer: Critical Grade Compact CPJ Series, Mounted to Engine 
  • Battery: 12 Volt System with Rack and Cables 
  • Flexible Fuel Connector 
  • Vibration Isolation Mounts 
  • Single Source Supplier 

Sound Data 

  • OPU: 82 dBA (No Load) / 85 dBA (Full Load) 
  • Level 1: 80 dBA (No Load) / 82 dBA (Full Load) 
  • Level 2: 75 dBA (No Load) / 78 dBA (Full Load) 
  • Level 3: 71 dBA (No Load) / 73 dBA (Full Load) 
  • Sound data measured at 23 feet (7 meters) per ISO 8528-10 

Factory Testing 

  • Verification of alarm shutdowns and voltage settings 
  • Block loading to rated kWe and power factor 
  • No load and max load tests at 1.0 PF and 0.8 PF 
  • Block loads at 0–25%, 0–50%, 0–75%, 0–100% of rated load 
  • Test metering accuracy: 1.3% or better, NIST traceable 
  • All procedures per MIL-STD-705C where applicable 

product specifications:

SpecificationValue
ModelJD150-01
kWe Rating (Standby)150 kWe
Frequency60 Hz
Speed1800 RPM
Voltage Options120/240V Single Phase; 208/240/480/600V Three Phase
Power Factor0.8 (Three Phase) / 1.0 (Single Phase 240V)
Fuel TypeDiesel
EPA CertificationTier 3
UL ListedUL 2200 & cUL Listed
CSA CertifiedYes
Seismic CertificationIBC 2021
NFPA ComplianceNFPA 110 / CSA C282
Paint ColorWhite (standard); Gray available
ENGINE
Engine ManufacturerJohn Deere
Engine Model6068HF285
Engine Type4-Cycle, 6-Cylinder Inline
AspirationTurbocharged with Charge Air Cooling (CAC)
Displacement415 cu. in. (6.80 L)
Bore x Stroke4.19 in. x 5.00 in.
Compression Ratio19.0:1
Rated RPM1800
Max Standby HP237 HP (177 kWm)
GovernorElectronic Isochronous
Air CleanerDry Single Stage
SilencerCritical Grade Compact (CPJ Series), Mounted to Engine
Battery12 Volt System with Rack and Cables
GENERATOR (ALTERNATOR)
Generator ManufacturerStamford
Generator Model (480V)UCI274F — 12 Lead Wye
Generator Model (208/240V 3Ph)UCI274G — 12 Lead Wye / Delta
Generator Model (240V 1Ph)UCDI274J1 — 12 Lead DD
Generator TypeBrushless, Single Bearing
Voltage RegulatorStamford AS440 Automatic Voltage Regulator
Voltage Regulation±1%
Poles4 Pole, Rotating Field
Standby Temp Rise125°C Rise Over 40°C Ambient
Harmonic Content5% Maximum
StandardsNEMA MG 1, IEEE and ANSI
CONTROL PANEL
Control Panel ModelBlue Star DCP7310 Microprocessor Based Gen-Set Controller
Control Panel EnclosureNEMA 12
NFPA 110 CompatibilityLevel 1 Compatible
Standard ShutdownsLow Oil Pressure, High Coolant Temp, Overspeed, Overcrank
Alarm FeaturesEmergency Stop Pushbutton, Audible Alarm Buzzer with Silencing Switch
ENCLOSURE
Enclosure LevelLevel 2 — Weather Proof with Foam
Enclosure MaterialPowder Coated 14 Gauge Steel
Wind Rating200 MPH (Rated per IBC 2021 / ASCE/SEI 7-16)
Roof DesignPitched Roof
Sound Attenuation1.5" Polydamp Type D Acoustical Foam (PAF)
DoorsKeyed Alike Lockable with Draw Down Latches and Stainless Steel Hinges
BaseFormed Steel with Mounting and Lifting Holes
Vibration IsolationIncluded
COOLING SYSTEM
Cooling TypeUnit Mounted Radiator
Ambient Capacity50°C (122°F)
Water Pump Flow Rate48.0 GPM (182 lit/min)
Heat Rejection to Coolant5,407 BTUM (94.6 kW)
FUEL SYSTEM
Fuel Tank Capacity375 Gallon (24 Hour)
Fuel Tank ListingUL 142 Listed Sub-Base, Double Wall, Secondary Containment
Fuel Consumption at 100%11.1 gal/hr
Fuel Consumption at 75%8.95 gal/hr
Fuel Consumption at 50%6.72 gal/hr
ELECTRICAL ACCESSORIES
Mainline Breaker225 Amp, 3 Pole, 600 Volt (NEMA 1 Enclosure)
Battery Charger12 Volt, 6 Amp, Mounted and Wired to Terminal
Jacket Water Heater2000W, 240VAC, Rated for -20°F, with Isolation Valves
EXHAUST SYSTEM
Exhaust Gas Temp (Stack)981°F (527°C)
Gas Volume at Stack Temp1,158 CFM (32.8 m³/min)
Max Exhaust Restriction30.0 in. H2O (7.50 kPa)
WARRANTY & TESTING
Warranty2 Year / 2000 Hour Limited
Factory TestStandard Commercial Testing — Block Loading to Rated kWe and PF

 

product related documents:

2026 EPA Cert 350hak-tjdxl06-8120-006 JD125-02, JD150-01.pdf

JD150-01 Engine Data Sheet 12-5-23.pdf

JD150-01_SpecSheet.pdf

JD150-01.pdf

JD150-01_Drawings.pdf

Additional Info
Weight4425 lbs
Dimensions130 × 54 × 74 in