Aksa Diesel Generator APD-ULM1000 (1000kW)



Aksa Diesel Generator APD-ULM1000 (1000kW)
Call for Price
A 1000 kW industrial diesel standby generator set from AKSA Power Generation, built around a Mitsubishi S12H-Y2PTAW-1 engine, a Stamford alternator, and a DSE 7320 control panel. Designed for demanding commercial and industrial standby applications, the unit is EPA-certified for emergency stationary use, UL2200 listed, and available on open skid or in sound-attenuated enclosures, with a heavy duty steel base frame and a full complement of standard protective and monitoring features.
Key Features
- 1000 kW / 1250 kVA standby diesel generator set powered by a Mitsubishi S12H-Y2PTAW-1 engine
- Stamford alternator paired with a DSE 7320 Auto Mains Failure control panel
- Operates at 60Hz / 1800rpm and is available in 480/277V, 240/120V, 208/120V, and 600/347V configurations
- UL2200 certified and EPA-certified for Emergency Stationary Applications
- Meets NFPA70, 99, 110, and 37 Level 1 requirements when installed per NFPA standards
- Manufactured in facilities certified to ISO9001 and ISO14001:2015 standards
- Available on open skid or in Level 1 / Level 2 sound-attenuated enclosures
- Heavy duty steel base frame with anti-vibration pads between engine/alternator and base frame
- Includes engine jacket water heater, battery and battery rack, and battery charger as standard equipment
- Backed by a 24 month / 2000 hour limited standby warranty, with an optional 5 year / 2000 hour comprehensive warranty
APD-ULM1000 product details and specifications:
General Characteristics
- Model Name: APD-ULM1000
- Engine Make: Mitsubishi
- Engine Model: S12H-Y2PTAW-1
- Alternator Make: Stamford
- Control Panel Make & Model: DSE 7320
- Frequency & Speed: 60Hz, 1800rpm
- Enclosure Make & Model: AKSA AUL 91/92
Genset Rating
- Standby Power: 1000 kW at 480/277V, 240/120V, 208/120V, and 600/347V
- Power Factor: 0.8
- Standby Current: 1504A (480/277V), 3007A (240/120V), 3470A (208/120V), 1204A (600/347V)
Engine Data
- Manufacturer: Mitsubishi
- Model: S12H-Y2PTAW-1
- Displacement & Cylinders: 37.11 L / 12 Cylinders
- Engine Speed: 1800 rpm
- Engine Standby Power wo/Fan: 1140 kW
- Engine Prime Power wo/Fan: 1036 kW
- Aspiration: Turbo-charged, InterCooler
- Compression Ratio: 14.5 : 1
- Bore / Stroke: 5.91 in / 6.89 in (150 mm / 175 mm)
- Break Mean Effective Pressure: 297 psi
- Mean Piston Speed: 10.5 m/s
- Allowable Fan Loss Power: 40 kW
- Max Regenerative Power Absorption Capacity wo Fan: 108 kW
- Steady State Speed Stability: ±0.25 %
- Max Over Speed Capacity: 2000 rpm
- Wet Weight – Engine Only: 10,055 lbs.
Fuel Consumption
- Standby Power (110%): 75.0 gal/h
- Prime Power (100%): 70.0 gal/h
- Prime Power (75%): 54.4 gal/h
- Prime Power (50%): 35.9 gal/h
- Prime Power (25%): 20.0 gal/h
Fuel System
- Fuel Injector: Mitsubishi Electrical Controlled x 12
- Max Suction of Feed Pump: 75 mmHg
- Max Static Head of Return & Leak Pipe: 220 mmHg
Air Intake System
- Intake Air Flow: 102 m3/min
- Max Intake Air Restriction (Clean Element): 400 mmH2O
- Air Filter Type: Dry Paper Element
Electric System
- Battery Charge Alternator: 24V / 30Ah
- Starting Motor Capacity: 7.5 kW x 2
- Battery Qty, Rating, CCA: 4 x 200Ah, 1150CCA
Cooling System
- Radiator Cooling System Type: Closed Circuit
- Radiator Ambient Temp: > 50 °C
- Coolant Capacity, Engine Only (Jacket & Air Cooler): 26.4 gal
- Max Coolant Temp at Engine Outlet: 208 °F
- Thermostat, Start – Fully Open: 160–185 °F
Exhaust System
- Exhaust Outlet Size: 7.95 in (202 mm)
- Max Allowable Back Pressure: 600 mmH2O
- Exhaust Gas Flow: 270 m3/min
Lubrication System
- Total System Capacity: 52.8 gal
- Sump Capacity Max / Min: 48 gal / 39.6 gal
- Max Oil Temp: 230 °F
- Oil Pressure at Rated Speed: 71–86 psi
Alternator Data
- Manufacturer: Stamford
- Standards: BS EN 60034
- Control System: PMG
- A.V.R.: MX321
- Voltage Regulation: ± 0.5 %
- Insulation System: Class H
- Protection: IP23
- Rated Power Factor: 0.8
- Stator Winding: Double Layer Concentric
- Winding Pitch: Two Thirds
- Winding Leads: 12
- Telephone Interference: THF < 2 %
- Waveform Distortion: No Load < 1.5 %
- Maximum Over Speed: 2250 rev/min
Controller Data
- Manufacturer: DSE
- Model: 7320
- Type: Auto Mains Failure Control
- Features: Microprocessor controlled, license-free PC software, IP65-rated modules, four line back-lit LCD display, five key menu navigation, front panel PIN protection, up to three remote display modules, configurable timers and alarms, multiple date/timer scheduler, integral PLC editor, kW & kVAr protection, reverse power protection, power monitoring, load shedding, unbalanced load protection, independent earth fault trip, SCADA monitoring via DSE Configuration Suite
Battery Charger & Electrical System Data
- Manufacturer: ComAp
- Model: InteliCharger
- Input Voltage: 85V ~ 264V AC
- Output Voltage / Current: 27.2V Float / 2.5A pk
Jacket Water Heater Data
- Manufacturer: Hotstart
- Model: CKM1060260-000
- Input Voltage: 240V
- Power: 6000W
Open Skid Gen-Set Dimensions
- Length: 209 in
- Width: 89 in
- Height: 88.7 in
- Dry Weight: 20,000 lbs.
Enclosed Gen-Set Dimensions – Level 1
- Length: 272.2 in
- Width: 89 in
- Height: 101.2 in
- Dry Weight: 25,545 lbs.
- Sound Pressure @ 7 meters: 83 dB(A)
Enclosed Gen-Set Dimensions – Level 2
- Length: 272.2 in
- Width: 89 in
- Height: 132.9 in
- Dry Weight: TBA
- Sound Pressure @ 7 meters: 80 dB(A) (Calculated Value)
Fuel Tank – UL142 Listed Base Design
- 24hr: 1,800 gal / 292x89x25 in / 5,700 lbs.
- 48hr: 3,600 gal / 370x89x36 in / 8,550 lbs.
- 72hr: 5,400 gal / 540x89x36 in / 11,950 lbs.
Codes & Standards
- Designed and manufactured in a facility certified to ISO9001 standards
- Designed and manufactured in a facility certified to ISO14001:2015 standards
- AKSA Power Generation provides single source responsibility for the generator set & accessories
- Prototype tested and production tested according to the UL test program
- Meets NFPA70, 99, 110, 37 Level 1 when equipped with the necessary accessories and installed per NFPA standards
- UL2200 Certified
- EPA Certified for Emergency Stationary Applications
Standard Features & Accessories
- Heavy Duty Steel Base Frame
- PMG w/MX321 AVR
- Engine Jacket Water Heater
- Battery and Battery Rack
- Battery Charger
- Anti Vibration Pads between Engine/Alternator & Base Frame
- Critical Grade Silencer Inside Enclosure
- Residential Grade Silencer Set for Open Skid Sets
- Exhaust outlet rain cap and radiator fill cap
- Sound Absorb Foam Material for Enclosure
- Emergency Stop Button
- Oil Drain Valve
- Coolant Drain Valve
- Jacket Water Heater Isolation Valves
- Flex Fuel Lines
- Air Filter Restriction Gauge
- Engine Manifold Cover
- Turbocharger Cover
- Protection Covers for Rotating Parts
- Exhaust Insulation Cover
- Enclosure DC Light
- Operations Manual
- 24 Months / 2000 hours Limited Standby Warranty
Optional Accessories
- Main Line CB (3/4 Poles – 80%/100% rated)
- Upsize Alternator
- Digital AVR
- Anti-condensation Heater
- Sub Base Fuel Tank (UL142 / UL2085)
- Fuel Level Display & Alarm on Controller
- Low / High Fuel Alarms
- Fuel Water Separator Filter
- Auto Fuel Fill Control System
- Oil Temperature Display on Controller
- Manual Speed Adjust Rheostat
- Manual Voltage Adjust Rheostat
- Remote Annunciator Panel
- Remote Control & Monitoring Panel
- Advanced SMS Messaging
- Control Panel Heater
- Battery Disconnect Switch
- Battery Heater
- Battery Charger 10/20 Amp
- Shunt Trip / Aux Contacts
- Spring Anti-vibration Isolators
- Automatic Transfer Panel (ATS)
- 5 Years / 2000 hours Limited Comprehensive Warranty
product specifications:
| Specification | Value |
| Model Name | APD-ULM1000 |
| Engine Make | Mitsubishi |
| Engine Model | S12H-Y2PTAW-1 |
| Alternator Make | Stamford |
| Control Panel Make & Model | DSE 7320 |
| Frequency & Speed | 60Hz, 1800rpm |
| Enclosure Make & Model | AKSA AUL 91/92 |
| Standby Power | 1000 kW |
| Power Factor | 0.8 |
| Voltage Options | 480/277V, 240/120V, 208/120V, 600/347V |
| Displacement & Cylinders | 37.11 L / 12 Cylinders |
| Engine Speed | 1800 rpm |
| Engine Standby Power wo/Fan | 1140 kW |
| Engine Prime Power wo/Fan | 1036 kW |
| Aspiration | Turbo-charged, InterCooler |
| Compression Ratio | 14.5 : 1 |
| Bore / Stroke | 5.91 in / 6.89 in (150 mm / 175 mm) |
| Break Mean Effective Pressure | 297 psi |
| Mean Piston Speed | 10.5 m/s |
| Allowable Fan Loss Power | 40 kW |
| Max Regenerative Power Absorption Capacity wo Fan | 108 kW |
| Steady State Speed Stability | ±0.25 % |
| Max Over Speed Capacity | 2000 rpm |
| Wet Weight – Engine Only | 10,055 lbs. |
| Fuel Consumption – Standby Power (110%) | 75.0 gal/h |
| Fuel Consumption – Prime Power (100%) | 70.0 gal/h |
| Fuel Consumption – Prime Power (75%) | 54.4 gal/h |
| Fuel Consumption – Prime Power (50%) | 35.9 gal/h |
| Fuel Consumption – Prime Power (25%) | 20.0 gal/h |
| Fuel Injector | Mitsubishi Electrical Controlled x 12 |
| Max Suction of Feed Pump | 75 mmHg |
| Max Static Head of Return & Leak Pipe | 220 mmHg |
| Intake Air Flow | 102 m3/min |
| Max Intake Air Restriction (Clean Element) | 400 mmH2O |
| Air Filter Type | Dry Paper Element |
| Battery Charge Alternator | 24V / 30Ah |
| Starting Motor Capacity | 7.5 kW x 2 |
| Battery Qty, Rating, CCA | 4 x 200Ah, 1150CCA |
| Radiator Cooling System Type | Closed Circuit |
| Radiator Ambient Temp | > 50 °C |
| Coolant Capacity, Engine Only (Jacket & Air Cooler) | 26.4 gal |
| Max Coolant Temp at Engine Outlet | 208 °F |
| Thermostat, Start – Fully Open | 160–185 °F |
| Exhaust Outlet Size | 7.95 in (202 mm) |
| Max Allowable Back Pressure | 600 mmH2O |
| Exhaust Gas Flow | 270 m3/min |
| Total System Capacity (Lubrication) | 52.8 gal |
| Sump Capacity Max / Min | 48 gal / 39.6 gal |
| Max Oil Temp | 230 °F |
| Oil Pressure at Rated Speed | 71–86 psi |
| Alternator Standards | BS EN 60034 |
| Alternator Control System | PMG |
| A.V.R. | MX321 |
| Voltage Regulation | ± 0.5 % |
| Insulation System | Class H |
| Protection | IP23 |
| Rated Power Factor | 0.8 |
| Stator Winding | Double Layer Concentric |
| Winding Pitch | Two Thirds |
| Winding Leads | 12 |
| Telephone Interference | THF < 2 % |
| Waveform Distortion | No Load < 1.5 % |
| Maximum Over Speed (Alternator) | 2250 rev/min |
| Controller Type | Auto Mains Failure Control |
| Battery Charger Manufacturer / Model | ComAp / InteliCharger |
| Battery Charger Input Voltage | 85V ~ 264V AC |
| Battery Charger Output Voltage / Current | 27.2V Float / 2.5A pk |
| Jacket Water Heater Manufacturer / Model | Hotstart / CKM1060260-000 |
| Jacket Water Heater Input Voltage | 240V |
| Jacket Water Heater Power | 6000W |
| Open Skid Length | 209 in |
| Open Skid Width | 89 in |
| Open Skid Height | 88.7 in |
| Open Skid Dry Weight | 20,000 lbs. |
| Enclosed Level 1 Length | 272.2 in |
| Enclosed Level 1 Width | 89 in |
| Enclosed Level 1 Height | 101.2 in |
| Enclosed Level 1 Dry Weight | 25,545 lbs. |
| Enclosed Level 1 Sound Pressure @ 7 meters | 83 dB(A) |
| Enclosed Level 2 Length | 272.2 in |
| Enclosed Level 2 Width | 89 in |
| Enclosed Level 2 Height | 132.9 in |
| Enclosed Level 2 Sound Pressure @ 7 meters | 80 dB(A) (Calculated Value) |
| Fuel Tank Size – 24hr | 1,800 gal / 5,700 lbs. |
| Fuel Tank Size – 48hr | 3,600 gal / 8,550 lbs. |
| Fuel Tank Size – 72hr | 5,400 gal / 11,950 lbs. |
| Certifications | ISO9001, ISO14001:2015, UL2200, EPA Stationary Standby, NFPA70/99/110/37 Level 1 |
| Warranty | 24 Months / 2000 hours Limited Standby Warranty |
product related documents:
| Weight | 25545 lbs |
|---|---|
| Dimensions | 272.2 × 89 × 101.2 in |
Only logged in customers who have purchased this product may leave a review.





Reviews
There are no reviews yet.