Aksa Diesel Generator APD-ULJ400 (400kW)

Share this product!

Aksa Diesel Generator APD-ULJ400 (400kW)

Call for Price

SKU: APD-ULJ400

The AKSA Power Generation APD-ULJ400 is a UL2200-listed, 400kW standby diesel generator set built around a John Deere 6135HFG84 engine and a Stamford alternator, controlled by a DSE 7320 MK II digital control panel. Operating at 60Hz and 1800rpm, the unit is designed and calibrated to meet EPA Tier 3 emissions standards and is certified for emergency stationary applications. Available in multiple voltage configurations and enclosure levels, the APD-ULJ400 delivers reliable three-phase standby power for industrial and commercial backup applications, backed by a 24-month/2000-hour limited standby warranty. 

Key Features 

  • 400kW standby power output at 0.8 power factor 
  • John Deere 6135HFG84 diesel engine – 13.5L, 6 cylinders, turbocharged & air-to-air aftercooled 
  • Stamford alternator with Class H insulation and IP23 protection 
  • DSE 7320 MK II controller – microprocessor controlled, UL & NFPA 110 compatible 
  • UL2200 certified and designed/calibrated to meet EPA Tier 3 emissions standards 
  • EPA-certified for emergency stationary applications 
  • Meets NFPA 70, 99, 110, and 37 Level 1 standards when properly installed 
  • Multiple voltage configurations: 480/277V, 240/120V, 208/120V, and 600/347V three-phase 
  • Available in Open Skid, Level 1, and Level 2 sound-attenuated enclosure configurations 
  • Standard jacket water heater, battery charger, and emergency stop button 
  • UL142-listed sub-base fuel tank options: 24hr (665gal), 48hr (1400gal), 72hr (2100gal) 
  • 24 months/2000 hours limited standby warranty (5-year comprehensive warranty optional) 
Share:
Description
Additional Info
Reviews
Description

 

APD-ULJ400 product details and specifications:

General Characteristics 

  • Model Name: APD-ULJ400 
  • Engine Make: John Deere 
  • Engine Model: 6135HFG84 
  • Alternator Make: Stamford 
  • Control Panel Make & Model: DSE 7320 MK II 
  • Frequency & Speed: 60Hz, 1800rpm 
  • Enclosure Make & Model: AKSA AUL 71/72 

Genset Rating 

  • 480/277V — Alternator HCI434F (Wnd-311) — 400kW, 0.8 PF, 601A Standby Current 
  • 240/120V — Alternator S5L1S-C (Wnd-311) — 400kW, 0.8 PF, 1203A Standby Current 
  • 208/120V — Alternator S5L1S-C (Wnd-311) — 400kW, 0.8 PF, 1388A Standby Current 
  • 600/347V — Alternator HCI434F (Wnd-17) — 400kW, 0.8 PF, 481A Standby Current 

Engine Data 

  • Manufacturer: John Deere 
  • Model: 6135HFG84 
  • Displacement & Cylinders: 13.5 L / 6 Cylinders 
  • Engine Type: In-line, 4 Cycle 
  • Engine Speed: 1800 rpm 
  • Engine Standby Power: 460 kW 
  • Aspiration: Turbocharged & Air to Air Aftercooled 
  • Compression Ratio: 16.0 : 1 
  • Bore / Stroke: 132 mm / 165 mm 
  • Governor Type: Electronic 
  • Engine Crankcase Vent System: Open 
  • Fan Power: 18.4 kW 
  • BMEP, Standby Power: 2271 kPa 
  • Friction Power: 41 kW 
  • Designed / Calibrated to Meet: EPA Tier 3 

Fuel System 

  • ECU Description: L15 Controller 
  • Max Fuel Inlet Temperature: 212 °F 
  • Total Fuel Flow: 357 lb/hr 

Fuel Consumption 

  • Standby Power (100%): 29.2 gal/h 
  • Standby Power (75%): 23.9 gal/h 
  • Standby Power (50%): 16.8 gal/h 
  • Standby Power (25%): 9.0 gal/h 

Electric System 

  • System Voltage: 12V / 24V 
  • Min Voltage at ECU during Crank: 6V for 12V system / 10V for 24V system 
  • Battery Qty, Rating: 2 x 120Ah 

Cooling System 

  • Radiator Cooling System Type: Closed Circuit 
  • Radiator Ambient Temp: > 50 °C 
  • Coolant Capacity, Engine Only: 19 quart 
  • Max Top Tank Temp: 221 °F 
  • Thermostat, Start – Fully Open: 180–198 °F 

Exhaust System 

  • Exhaust Temperature: 981 °F 
  • Max Allowable Exhaust Restriction: 7.5 kPa 
  • Exhaust Gas Flow: 2606 ft³/min 

Air Intake System 

  • Engine Air Flow: 996 ft³/min 
  • Max Intake Air Restriction (Clean Element): 3.75 kPa 
  • Air Filter Type: Dry Paper Element 

Lubrication System 

  • Oil Pressure at Rated Speed: 234 kPa 
  • In-Pan Oil Temperature: 235 °F 
  • Max Oil Carryover in Blow-by: 0.007 lb/hr 
  • Max Crankcase Pressure: 0.5 kPa 

Alternator Data 

  • Manufacturer: Stamford 
  • Standards: BS EN 60034 
  • Control System: PMG 
  • A.V.R.: MX341 
  • Voltage Regulation: ± 1% 
  • Insulation System: Class H 
  • Protection: IP23 
  • Rated Power Factor: 0.8 
  • Stator Winding: Double Layer Concentric 
  • Winding Pitch: Two Thirds 
  • Winding Leads: 12 
  • Telephone Interference: THF < 2% 
  • Waveform Distortion: No Load < 1.5% 
  • Maximum Over Speed: 2250 rev/min 

Controller Data 

  • Manufacturer: DSE 
  • Model: 7320 MK II 

Controller Features & Benefits 

  • Microprocessor controlled, UL & NFPA110 Compatible 
  • License free PC Software (Non-proprietary Software) 
  • IP65 rating offers increased resistance to water ingress 
  • Modules can be integrated to building management systems 
  • Real time clock provides accurate event log 
  • Four line back-lit LCD text display 
  • Five key menu navigation, two wire start/stop at Auto mode 
  • Front panel editing with PIN protection 
  • Support up to three remote display modules 
  • Configurable timers and alarms 
  • Multiple date and timer scheduler 
  • Integral PLC editor 
  • 'Protections disabled' feature 
  • Load switching (load shedding and dummy load outputs) 
  • Fully configurable via DSE Configuration Suite PC Software 
  • SCADA monitoring via DSE Configuration Suite PC Software 

Battery Charger & Electrical System Data 

  • Manufacturer: ComAp 
  • Model: InteliCharger 
  • Input Voltage: 85V ~ 264V AC 
  • Output Voltage / Current: 27.2V Float / 2.5A pk 

Jacket Water Heater Data 

  • Manufacturer: Hotstart 
  • Model: CTM25210-N00 
  • Input Voltage: 240V 
  • Power: 2500W 

Protection 

  • Gen. Voltage – under / over 
  • Gen. Freq. – under / over 
  • Engine Speed – under / over 
  • Engine Oil Pressure – low 
  • Engine Temp – low / high 
  • Battery Voltage – low / high 
  • Weak Battery 
  • Fail to Start / Stop 
  • Charge Alternator Fail 
  • Over Current & Load (kW/kVAr) 
  • Unbalanced Load 
  • Independent Earth Fault 
  • Reverse Power 
  • Loss of Speed Signal 

Instruments 

  • Gen. Voltage (L-L/L-N) 
  • Gen. Frequency 
  • Engine Speed 
  • Oil Pressure 
  • Water Temperature 
  • Battery Voltage 
  • Run Time 
  • Phase Sequence 
  • Power monitoring (kWh/kVAh/kVArh) 
  • Power (kWh/kVAh/kVArh) 
  • Power Factor 
  • Generator Current 
  • Generator Load (%) 
  • Earth Current 

Enclosure Features 

  • Heavy Duty Steel / Aluminum Structure 
  • E-Stop on Enclosure 
  • Control Panel Eliminated from Engine Vibrations 
  • Standard Sound Attenuation Foam 
  • Plastic Covered Corrosion Resistant Locks & Hinges 
  • Internally Mounted Exhaust System with Rain Cap 
  • Coolant Fill Cap 
  • Removable Base Frame Lifting Hooks 
  • Oil & Coolant Drain Ports 
  • Easy Access for Maintenance 

Dimensions & Weight 

  • Open Skid Gen: 157.5 in (L) x 74.8 in (W) x 71 in (H), Dry Weight 8975 lb 
  • Level 1 Enclosure: 205 in (L) x 77 in (W) x 89.9 in (H), Dry Weight 12400 lb, Sound Pressure 77 dB(A) @ 7m 
  • Level 2 Enclosure: 224.6 in (L) x 77 in (W) x 89.9 in (H), Dry Weight 12775 lb, Sound Pressure 75 dB(A) @ 7m 

Fuel Tank – UL142 Listed Base Design 

  • 24hr (665gal): 225 x 74.8 x 15.5 in, Weight 2900 lb 
  • 48hr (1400gal): 225 x 74.8 x 29.5 in, Weight 3800 lb 
  • 72hr (2100gal): 260 x 74.8 x 36 in, Weight 4710 lb 

Standard Features & Accessories 

  • UL2200 Certification 
  • Heavy Duty Steel Base Frame 
  • PMG w/MX341 AVR 
  • Engine Jacket Water Heater 
  • Battery and Battery Rack 
  • Battery Charger 
  • Anti Vibration Pads between Engine/Alternator & Base Frame 
  • Critical Grade Silencer Inside Enclosure 
  • Residential Grade Silencer Set for Open Skid Sets 
  • Exhaust Outlet Rain Cap and Radiator Fill Cap 
  • Sound Absorb Foam Material for Enclosure 
  • Emergency Stop Button 
  • Oil Drain Valve 
  • Coolant Drain Valve 
  • Jacket Water Heater Isolation Valves 
  • Flex Fuel Lines 
  • Air Filter Restriction Gauge 
  • Engine Manifold Cover 
  • Turbocharger Cover 
  • Protection Covers for Rotating Parts 
  • Exhaust Insulation Cover 
  • Enclosure DC Light 
  • Operations Manual 
  • 24 Months / 2000 Hours Limited Standby Warranty 

Optional Accessories 

  • Main Line CB (3 / 4 Poles – 80% / 100% rated) 
  • Upsize Alternator 
  • Voltage Regulation ±0.5% w/MX321 AVR 
  • Anti-condensation Heater 
  • Sub Base Fuel Tank (UL142 / UL2085) 
  • Fuel Level Display & Alarm on Controller 
  • Low / High Fuel Alarms 
  • Fuel Water Separator Filter 
  • Auto Fuel Fill Control System 
  • Oil Temperature Display on Controller 
  • Manual Speed Adjust Rheostat 
  • Manual Voltage Adjust Rheostat 
  • Remote Annunciator Panel 
  • Remote Control & Monitoring Panel 
  • Advanced SMS Messaging 
  • Control Panel Heater 
  • Battery Disconnect Switch 
  • Battery Heater 
  • Battery Charger 10/20 Amp 
  • Shunt Trip / Aux Contacts 
  • Spring Anti-vibration Isolators 
  • Automatic Transfer Panel (ATS) 
  • 5 Years / 2000 Hours Limited Comprehensive Warranty 

Codes & Standards 

  • Designed and manufactured in a facility certified to ISO9001 standards 
  • Designed and manufactured in a facility certified to ISO14001:2015 standards 
  • AKSA Power Generation provides single source responsibility for the generator set & accessories 
  • Prototype tested and production tested according to the UL test program 
  • Meets NFPA70, 99, 110, 37 Level 1 when equipped with the necessary accessories and installed per NFPA standards 

product specifications:

SpecificationValue
Model NameAPD-ULJ400
Engine MakeJohn Deere
Engine Model6135HFG84
Alternator MakeStamford
Control Panel Make & ModelDSE 7320 MK II
Frequency & Speed60Hz, 1800rpm
Enclosure Make & ModelAKSA AUL 71/72
Standby Power400 kW
Power Factor0.8
Voltage Options480/277V, 240/120V, 208/120V, 600/347V (Three Phase)
Standby Current (480/277V)601 A
Standby Current (240/120V)1203 A
Standby Current (208/120V)1388 A
Standby Current (600/347V)481 A
Engine Displacement & Cylinders13.5 L / 6 Cylinders
Engine TypeIn-line, 4 Cycle
Engine Speed1800 rpm
Engine Standby Power460 kW
AspirationTurbocharged & Air to Air Aftercooled
Compression Ratio16.0 : 1
Bore / Stroke5.2 in / 6.5 in
Governor TypeElectronic
Engine Crankcase Vent SystemOpen
Fan Power18.4 kW
BMEP, Standby Power2271 kPa
Friction Power41 kW
Emissions CertificationEPA Tier 3
Fuel Consumption (100%)29.2 gal/h
Fuel Consumption (75%)23.9 gal/h
Fuel Consumption (50%)16.8 gal/h
Fuel Consumption (25%)9.0 gal/h
Total Fuel Flow357 lb/hr
Max Fuel Inlet Temperature212 °F
System Voltage12V / 24V
Battery Qty, Rating2 x 120Ah
Radiator Cooling System TypeClosed Circuit
Coolant Capacity, Engine Only19 quart
Max Top Tank Temp221 °F
Exhaust Temperature981 °F
Exhaust Gas Flow2606 ft³/min
Engine Air Flow996 ft³/min
Air Filter TypeDry Paper Element
Oil Pressure at Rated Speed234 kPa
Alternator StandardsBS EN 60034
Alternator Insulation SystemClass H
Alternator ProtectionIP23
Alternator Voltage Regulation± 1%
Controller Make & ModelDSE 7320 MK II
Battery Charger Make & ModelComAp InteliCharger
Jacket Water Heater Make & ModelHotstart CTM25210-N00
Jacket Water Heater Power2500 W
Open Skid Dimensions (L x W x H)157.5 in x 74.8 in x 71 in
Open Skid Dry Weight8975 lbs.
Level 1 Enclosure Dimensions (L x W x H)205 in x 77 in x 89.9 in
Level 1 Enclosure Dry Weight12400 lbs.
Level 1 Sound Pressure @ 7m77 dB(A)
Level 2 Enclosure Dimensions (L x W x H)224.6 in x 77 in x 89.9 in
Level 2 Enclosure Dry Weight12775 lbs.
Level 2 Sound Pressure @ 7m75 dB(A)
Fuel Tank 24hr Capacity / Weight665 gal / 2900 lbs.
Fuel Tank 48hr Capacity / Weight1400 gal / 3800 lbs.
Fuel Tank 72hr Capacity / Weight2100 gal / 4710 lbs.
Standby Warranty24 Months / 2000 Hours (Limited)

 

product related documents:

APD-ULJ400.pdf

Additional Info
Weight12775 lbs
Dimensions224.6 × 77 × 89.9 in
Reviews

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Item added to cart View Cart Checkout
Item added to wishlist View Wishlist
Item removed from wishlist