The AKSA Power Generation APD-ULJ300 is a UL2200-listed, 300 kW diesel standby generator set built around a John Deere 6090HFG86 engine and a Stamford alternator. Engineered for reliable emergency and standby power in commercial and industrial applications, it pairs a DSE 7320 MK II digital control panel with a heavy-duty steel and aluminum enclosure available in open skid, Level 1, or Level 2 sound-attenuated configurations. The unit meets NFPA 70, 99, 110, and 37 Level 1 requirements and is backed by a 24-month / 2,000-hour limited standby warranty. 

Key Features 

  • 300 kW / 375 kVA standby power output at 0.8 power factor, 60 Hz / 1800 rpm 
  • Powered by a John Deere 6090HFG86 diesel engine (9L, 6-cylinder, turbocharged & air-to-air aftercooled), designed to meet EPA Tier 3 
  • Stamford alternator with Class H insulation, IP23 protection, and ±1% voltage regulation 
  • DSE 7320 MK II digital controller — UL & NFPA 110 compatible, with SCADA monitoring and remote display support 
  • UL2200 certified and meets NFPA 70, 99, 110, and 37 Level 1 standards 
  • Available in Open Skid, Level 1, and Level 2 sound-attenuated enclosure configurations 
  • Heavy-duty steel/aluminum enclosure with critical grade silencer and sound-absorbing foam 
  • Engine jacket water heater (Hotstart) and battery charger (ComAp InteliCharger) included as standard 
  • UL142-listed sub-base fuel tank options available in 24-hour, 48-hour, and 72-hour capacities 
  • 24 months / 2,000 hours limited standby warranty, with extended coverage available 
Share:
Description
Additional Info
Reviews
Description

 

APD-ULJ300 product details and specifications:

General Characteristics 

  • Model Name: APD-ULJ300 
  • Engine Make: John Deere 
  • Engine Model: 6090HFG86 
  • Alternator Make: Stamford 
  • Control Panel Make & Model: DSE 7320 MK II 
  • Frequency & Speed: 60 Hz, 1800 rpm 
  • Enclosure Make & Model: AKSA AUL 71/72 

Genset Rating 

  • Standby Power: 300 kW at 0.8 Power Factor 
  • 480/277V — Alternator HCI434D (Wnd-311) — 452A Standby Current 
  • 240/120V — Alternator S4L1S-E (Wnd-311) — 902A Standby Current 
  • 208/120V — Alternator S4L1S-E (Wnd-311) — 1041A Standby Current 
  • 600/347V — Alternator HCI434D (Wnd-17) — 361A Standby Current 

Engine Data 

  • Manufacturer: John Deere 
  • Model: 6090HFG86 
  • Displacement & Cylinders: 9 L / 6 Cylinders 
  • Engine Type: In-line, 4 Cycle 
  • Engine Speed: 1800 rpm 
  • Engine Standby Power: 345 kW 
  • Aspiration: Turbocharged & Air to Air Aftercooled 
  • Compression Ratio: 16.0 : 1 
  • Bore / Stroke: 4.66 in / 5.35 in (118.4 mm / 136 mm) 
  • Governor Type: Electronic 
  • Engine Crankcase Vent System: Open 
  • Fan Power: 13.8 kW 
  • BMEP, Standby Power: 2556 kPa 
  • Friction Power: 24 kW 
  • Designed / Calibrated to Meet: EPA Tier 3 

Fuel System 

  • ECU Description: L14 Controller 
  • Max Fuel Inlet Temp.: 176 °F 
  • Total Fuel Flow: 450 lb/hr 

Fuel Consumption 

  • Standby Power (100%): 22.11 gal/h 
  • Standby Power (75%): 17.78 gal/h 
  • Standby Power (50%): 13.07 gal/h 
  • Standby Power (25%): 6.92 gal/h 

Electric System 

  • System Voltage: 12V / 24V 
  • Min Voltage at ECU during crank: 6V for 12V system / 10V for 24V system 
  • Battery Qty, Rating: 2 x 120Ah 

Cooling System 

  • Radiator Cooling System Type: Closed Circuit 
  • Radiator Ambient Temp: > 50 °C 
  • Coolant Capacity, Engine Only: 16.9 quart 
  • Max Top Tank Temp: 230 °F 
  • Thermostat, Start – Fully Open: 180–201 °F 

Exhaust System 

  • Exhaust Temperature: 927 °F 
  • Max Allowable Exhaust Restriction: 7.5 kPa 
  • Exhaust Gas Flow: 2246 ft³/min 

Air Intake System 

  • Engine Air Flow: 936 ft³/min 
  • Max Intake Air Restriction (Clean Element): 3.75 kPa 
  • Air Filter Type: Dry Paper Element 

Lubrication System 

  • Oil Pressure at Rated Speed: 260 kPa 
  • In-Pan Oil Temperature: 241 °F 
  • Max Oil Carryover in Blow-by: 0.002 lb/hr 
  • Max Crankcase Pressure: 0.5 kPa 

Alternator Data 

  • Manufacturer: Stamford 
  • Standards: BS EN 60034 
  • Control System: PMG 
  • A.V.R.: MX341 
  • Voltage Regulation: ± 1% 
  • Insulation System: Class H 
  • Protection: IP23 
  • Rated Power Factor: 0.8 
  • Stator Winding: Double Layer Concentric 
  • Winding Pitch: Two Thirds 
  • Winding Leads: 12 
  • Telephone Interference: THF < 2% 
  • Waveform Distortion: No Load < 1.5% 
  • Maximum Over Speed: 2250 rev/min 

Controller Data 

  • Manufacturer: DSE 
  • Model: 7320 MK II 
  • Microprocessor controlled, UL & NFPA110 Compatible 
  • License free PC Software (Non-proprietary Software) 
  • IP65 rating offers increased resistance to water ingress 
  • Modules can be integrated to building management systems 
  • Real time clock provides accurate event log 
  • Four line back-lit LCD text display 
  • Five key menu navigation, two wire start/stop at Auto mode 
  • Front panel editing with PIN protection 
  • Support up to three remote display modules 
  • Configurable timers and alarms 
  • Multiple date and timer scheduler 
  • Integral PLC editor 
  • 'Protections disabled' feature 
  • Load switching (load shedding and dummy load outputs) 
  • Fully configurable via DSE Configuration Suite PC Software 
  • SCADA monitoring via DSE Configuration Suite PC Software 

Battery Charger & Electrical System Data 

  • Manufacturer: ComAp 
  • Model: InteliCharger 
  • Input Voltage: 85V ~ 264V AC 
  • Output Voltage / Current: 27.2V Float / 2.5A pk 

Jacket Water Heater Data 

  • Manufacturer: Hotstart 
  • Model: CTM25210-N00 
  • Input Voltage: 240V 
  • Power: 2500W 

Protection 

  • Gen. Voltage – under / over 
  • Gen. Freq. – under / over 
  • Engine Speed – under / over 
  • Engine Oil Pressure – low 
  • Engine Temp – low / high 
  • Battery Voltage – low / high 
  • Weak Battery 
  • Fail to Start / Stop 
  • Charge Alternator Fail 
  • Over Current & Load (kW/kVAr) 
  • Unbalanced Load 
  • Independent Earth Fault 
  • Reverse Power 
  • Loss of Speed Signal 

Instruments 

  • Gen. Voltage (L-L/L-N) 
  • Gen. Frequency 
  • Engine Speed 
  • Oil Pressure 
  • Water Temperature 
  • Battery Voltage 
  • Run Time 
  • Phase Sequence 
  • Power monitoring (kWh/kVAh/kVArh) 
  • Power (kWh/kVAh/kVArh) 
  • Power Factor 
  • Generator Current 
  • Generator Load (%) 
  • Earth Current 

Enclosure Features 

  • Heavy Duty Steel / Aluminum Structure 
  • E-Stop on Enclosure 
  • Control Panel Eliminated from Engine Vibrations 
  • Standard Sound Attenuation Foam 
  • Plastic Covered Corrosion Resistant Locks & Hinges 
  • Internally Mounted Exhaust System with Rain Cap 
  • Coolant Fill Cap 
  • Removable Base Frame Lifting Hooks 
  • Oil & Coolant Drain Ports 
  • Easy Access for Maintenance 

Dimensions & Weight — Open Skid Gen 

  • Length: 157.5 in 
  • Width w/o lift hooks: 74.8 in 
  • Height: 71 in 
  • Dry Weight: 7325 lb 

Dimensions & Weight — Level 1 Enclosure 

  • Length: 205 in 
  • Width w/o lift hooks: 77 in 
  • Height: 89.9 in 
  • Dry Weight: 10750 lb 
  • Sound Pressure @ 7 meters: 77 dB(A) 

Dimensions & Weight — Level 2 Enclosure 

  • Length: 224.6 in 
  • Width w/o lift hooks: 77 in 
  • Height: 89.9 in 
  • Dry Weight: 11125 lb 
  • Sound Pressure @ 7 meters: 75 dB(A) 

Fuel Tank — UL142 Listed Base Design 

  • 24hr (600 gal): Dimensions (L/W/H) 225 / 74.8 / 14.5 in — Weight 2800 lb 
  • 48hr (1200 gal): Dimensions (L/W/H) 225 / 74.8 / 25.5 in — Weight 3550 lb 
  • 72hr (1780 gal): Dimensions (L/W/H) 225 / 74.8 / 36 in — Weight 4200 lb 

Standard Features & Accessories 

  • UL2200 Certification 
  • Heavy Duty Steel Base Frame 
  • PMG w/MX341 AVR 
  • Engine Jacket Water Heater 
  • Battery and Battery Rack 
  • Battery Charger 
  • Anti Vibration Pads between Engine/Alternator & Base Frame 
  • Critical Grade Silencer Inside Enclosure 
  • Residential Grade Silencer Set for Open Skid Sets 
  • Exhaust outlet rain cap and radiator fill cap 
  • Sound Absorb Foam Material for Enclosure 
  • Emergency Stop Button 
  • Oil Drain Valve 
  • Coolant Drain Valve 
  • Jacket Water Heater Isolation Valves 
  • Flex Fuel Lines 
  • Air Filter Restriction Gauge 
  • Engine Manifold Cover 
  • Turbocharger Cover 
  • Protection Covers for Rotating Parts 
  • Exhaust Insulation Cover 
  • Enclosure DC Light 
  • Operations Manual 
  • 24 Months / 2000 hours Limited Standby Warranty 

Optional Accessories 

  • Main Line CB (3 / 4 Poles – 80% / 100% rated) 
  • Upsize Alternator 
  • Voltage Regulation ±0.5% w/MX321 AVR 
  • Anti-condensation Heater 
  • Sub Base Fuel Tank (UL142 / UL2085) 
  • Fuel Level Display & Alarm on Controller 
  • Low / High Fuel Alarms 
  • Fuel Water Separator Filter 
  • Auto Fuel Fill Control System 
  • Oil Temperature Display on Controller 
  • Manual Speed Adjust Rheostat 
  • Manual Voltage Adjust Rheostat 
  • Remote Annunciator Panel 
  • Remote Control & Monitoring Panel 
  • Advanced SMS Messaging 
  • Control Panel Heater 
  • Battery Disconnect Switch 
  • Battery Heater 
  • Battery Charger 10/20 Amp 
  • Shunt Trip / Aux Contacts 
  • Spring Anti-vibration Isolators 
  • Automatic Transfer Panel (ATS) 
  • 5 Years / 2000 hours Limited Comprehensive Warranty 

Codes & Standards 

  • Designed and manufactured in a facility certified to ISO 9001 standards 
  • Designed and manufactured in a facility certified to ISO 14001:2015 standards 
  • AKSA Power Generation provides single source responsibility for the generator set & accessories 
  • Prototype tested and production tested according to the UL test program 
  • Meets NFPA 70, 99, 110, 37 Level 1 when equipped with necessary accessories and installed per NFPA standards 
  • UL2200 Listed — Diesel 
  • EPA – Certified for Emergency Stationary Applications 

product specifications:

SpecificationValue
Model NameAPD-ULJ300
Engine MakeJohn Deere
Engine Model6090HFG86
Alternator MakeStamford
Control Panel Make & ModelDSE 7320 MK II
Frequency & Speed60 Hz, 1800 rpm
Enclosure Make & ModelAKSA AUL 71/72
Standby Power Rating300 kW
Power Factor0.8
Displacement & Cylinders9 L / 6 Cylinders
Engine TypeIn-line, 4 Cycle
Engine Standby Power345 kW
AspirationTurbocharged & Air to Air Aftercooled
Compression Ratio16.0 : 1
Bore / Stroke4.66 in / 5.35 in
Governor TypeElectronic
Engine Crankcase Vent SystemOpen
Fan Power13.8 kW
BMEP, Standby Power2556 kPa
Friction Power24 kW
Designed / Calibrated to MeetEPA Tier 3
ECU DescriptionL14 Controller
Max Fuel Inlet Temp.176 F
Total Fuel Flow450 lb/hr
Fuel Consumption @ 100% Standby Power22.11 gal/h
Fuel Consumption @ 75% Standby Power17.78 gal/h
Fuel Consumption @ 50% Standby Power13.07 gal/h
Fuel Consumption @ 25% Standby Power6.92 gal/h
System Voltage12V / 24V
Min Voltage at ECU during Crank6V (12V system) / 10V (24V system)
Battery Qty, Rating2 x 120Ah
Radiator Cooling System TypeClosed Circuit
Radiator Ambient Temp> 122 F
Coolant Capacity, Engine Only16.9 quart
Max Top Tank Temp230 F
Thermostat, Start - Fully Open180-201 F
Exhaust Temperature927 F
Max Allowable Exhaust Restriction7.5 kPa
Exhaust Gas Flow2246 ft3/min
Engine Air Flow936 ft3/min
Max Intake Air Restriction (Clean Element)3.75 kPa
Air Filter TypeDry Paper Element
Oil Pressure at Rated Speed260 kPa
In-Pan Oil Temperature241 F
Max Oil Carryover in Blow-by0.002 lb/hr
Max Crankcase Pressure0.5 kPa
Alternator StandardsBS EN 60034
Alternator Control SystemPMG
A.V.R.MX341
Voltage Regulation+/- 1%
Insulation SystemClass H
Alternator ProtectionIP23
Rated Power Factor0.8
Stator WindingDouble Layer Concentric
Winding PitchTwo Thirds
Winding Leads12
Telephone InterferenceTHF < 2%
Waveform DistortionNo Load < 1.5%
Maximum Over Speed2250 rev/min
Controller ManufacturerDSE
Controller Model7320 MK II
Battery Charger ManufacturerComAp
Battery Charger ModelInteliCharger
Battery Charger Input Voltage85V - 264V AC
Battery Charger Output Voltage / Current27.2V Float / 2.5A pk
Jacket Water Heater ManufacturerHotstart
Jacket Water Heater ModelCTM25210-N00
Jacket Water Heater Input Voltage240V
Jacket Water Heater Power2500W
Open Skid Gen - Length157.5 in
Open Skid Gen - Width w/o Lift Hooks74.8 in
Open Skid Gen - Height71 in
Open Skid Gen - Dry Weight7325 lb
Level 1 Enclosure - Length205 in
Level 1 Enclosure - Width w/o Lift Hooks77 in
Level 1 Enclosure - Height89.9 in
Level 1 Enclosure - Dry Weight10750 lb
Level 1 Enclosure - Sound Pressure @ 7m77 dB(A)
Level 2 Enclosure - Length224.6 in
Level 2 Enclosure - Width w/o Lift Hooks77 in
Level 2 Enclosure - Height89.9 in
Level 2 Enclosure - Dry Weight11125 lb
Level 2 Enclosure - Sound Pressure @ 7m75 dB(A)
Fuel Tank 24hr (600gal) - Dimensions (L/W/H)225 / 74.8 / 14.5 in
Fuel Tank 24hr (600gal) - Weight2800 lb
Fuel Tank 48hr (1200gal) - Dimensions (L/W/H)225 / 74.8 / 25.5 in
Fuel Tank 48hr (1200gal) - Weight3550 lb
Fuel Tank 72hr (1780gal) - Dimensions (L/W/H)225 / 74.8 / 36 in
Fuel Tank 72hr (1780gal) - Weight4200 lb

 

product related documents:

APD-ULJ300.pdf

Additional Info
Weight11125 lbs
Dimensions224.6 × 77 × 89.9 in
Reviews

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Item added to cart View Cart Checkout
Item added to wishlist View Wishlist
Item removed from wishlist