Aksa Gas Generator APD-NG650 (650kW)



Aksa Gas Generator APD-NG650 (650kW)
Call for Price
The AKSA Power Generation APD-NG650 is a UL2200-certified industrial standby generator set delivering 650 kW on Natural Gas and 420 kW on LP Gas at 60Hz. Built around a PSI (Doosan) 32L engine, a Stamford alternator, and a DSE 7320 MK II controller, this dual-fuel unit is housed in a heavy-duty steel/aluminum sound-attenuated enclosure and is designed to meet NFPA 70, 99, 110, and 37 Level 1 requirements for reliable emergency and standby power applications.
Key Features
- UL2200 Certification for Natural Gas / LP Gas operation
- 650 kW Natural Gas / 420 kW LP Gas standby power output at 60Hz, 1800 rpm
- Powered by a PSI (Doosan) 32L, V-type 4-cycle, turbo charge air cooled engine
- Stamford alternator with Class H insulation and ±0.5% voltage regulation (MX321 AVR)
- DSE 7320 MK II digital controller — microprocessor controlled, UL & NFPA 110 compatible
- Heavy Duty Steel/Aluminum enclosure (AKSA AUL 96) with sound attenuation foam
- Engine Jacket Water Heater, Battery Charger, and PMG excitation system included
- Meets NFPA 70, 99, 110, and 37 Level 1 requirements when properly equipped
- Dual fuel flexibility — runs on Natural Gas or LP Gas
- 24 Months / 2000 hours Limited Standby Warranty (5-Year Comprehensive optional)
APD-NG650 product details and specifications:
General Characteristics
- Model Name: APD-NG650
- Engine Make: PSI (Doosan)
- Engine Model: 32L
- Alternator Make: Stamford
- Control Panel Make & Model: DSE 7320 MK II
- Frequency & Speed: 60Hz, 1800 rpm
- Enclosure Make & Model: AKSA AUL 96
Genset Rating
- 208/120V, 0.8 PF — 650 kW NG (2255 A) / 420 kW LP (1457 A)
- 240/120V, 0.8 PF — 650 kW NG (1955 A) / 420 kW LP (1263 A)
- 480/277V, 0.8 PF — 650 kW NG (977 A) / 420 kW LP (632 A)
- 600/347V, 0.8 PF — 650 kW NG (782 A) / 420 kW LP (505 A)
Engine Data
- Manufacturer: PSI
- Model: 32L
- Displacement & Cylinders: 31.8 L / 12 Cylinders
- Engine Type: V-type, 4 Cycle
- Engine Speed: 1800 rpm
- Engine Standby Power NG: 720 kWm
- Engine Standby Power LP: 475 kW
- Aspiration: Turbo Charge Air Cooled
- Compression Ratio: 10.5:1
- Bore / Stroke: 5.91 in / 5.91 in
- Governor Type: Electronic
Fuel System
- Fuel Type: NG, LP Gas / Dual Fuel
- NG Supply Pipe Size: 3.0" NPTF
- Maximum EPR Rated Pressure: 6.9 kPa
- Recommended Max Pressure: 2.7 kPa / 11.0 inH2O
- Recommended Min Pressure: 1.7 kPa / 7.0 inH2O
Fuel Consumption
- Standby Power (100%): 7,983 ft³/h NG / 70 gal/h LP
- Standby Power (75%): 6,202 ft³/h NG / 52 gal/h LP
- Standby Power (50%): 4,478 ft³/h NG / 36 gal/h LP
Electric System
- System Voltage (dc): 24V
- Battery Qty, Rating: 2 x 143 Ah
Cooling System
- Radiator Cooling System Type: Closed Circuit
- Coolant Capacity: 54 gal
- Cranking Temperature: 176°F
- Full Open Temperature: 198°F
Exhaust System
- Type: Water cooled manifold
- Max. Allowable Back Pressure: 10.2 kPa
- Turbine Outlet Temperature: 1138°F / 639°C
- Exhaust Gas Flow at Turbine Outlet Temperature: 4,354 cfm
Air Intake System
- Combustion Air Required: 1,390 cfm
- Max Intake Air Restriction (Clean Element): 1.2 kPa / 5 inH2O
- Air Filter Type: Dry Paper Element
Lubrication System
- Oil Specifications: SAE 15W-40 Low Ash Gas Engine oil, API CD/CF or higher
- Oil Capacity, Min-Max: 95 – 129 Qts
- Oil Filter: 2, Cartridge
- Min – Max Oil Pressure @1000rpm (Idle): 74 psi – 83 psi / 5.1 – 5.7 bar
Alternator Data
- Manufacturer: Stamford
- Standards: BS EN 60034
- Control System: PMG
- A.V.R.: MX321
- Voltage Regulation: ±0.5%
- Insulation System: Class H
- Protection: IP23
- Rated Power Factor: 0.8
- Stator Winding: Double Layer Lap
- Winding Pitch: Two Thirds
- Winding Leads: 12
- Telephone Interference: THF < 2%
- Waveform Distortion: 0.5 < No Load < 1.5%
- Maximum Overspeed: 2,250 rev/min
Battery Charger & Electrical System Data
- Manufacturer: ComAp
- Model: InteliCharger
- Input Voltage: 90V ~ 277V AC
- Output Voltage / Current: 24V Float / 3A pk
Jacket Water Heater Data
- Manufacturer: Hotstart
- Model: CKM1060260-000
- Input Voltage: 240V
- Power: 6000W
Controller Data
- Manufacturer: DSE
- Model: 7320 MK II
Controller Features & Benefits
- Microprocessor controlled, UL & NFPA 110 Compatible
- License free PC Software (Non-proprietary Software)
- IP65 rating offers increased resistance to water ingress
- Modules can be integrated to building management systems
- Real time clock provides accurate event log
- Four line back-lit LCD text display
- Five key menu navigation, two wire start/stop at Auto mode
- Front panel editing with PIN protection
- Support up to three remote display modules
- Configurable timers and alarms
- Multiple date and timer scheduler
- Integral PLC editor
- 'Protections disabled' feature
- Load switching (load shedding and dummy load outputs)
- Fully configurable via DSE Configuration Suite PC Software
- SCADA monitoring via DSE Configuration Suite PC Software
Protection
- Gen. Voltage – under / over
- Gen. Freq. – under / over
- Engine Speed – under / over
- Engine Oil Pressure – low
- Engine Temp – low / high
- Battery Voltage – low / high
- Weak Battery
- Fail to Start / Stop
- Charge Alternator Fail
- Over Current & Load (kW/kVAr)
- Unbalanced Load
- Independent Earth Fault
- Reverse Power
- Loss of Speed Signal
Instruments
- Gen. Voltage (L-L/L-N)
- Gen. Frequency
- Engine speed
- Oil Pressure
- Water Temperature
- Battery Voltage
- Run Time
- Phase Sequence
- Power monitoring (kWh/kVAh/kVArh)
- Power (kWh/kVAh/kVArh)
- Power Factor
- Generator Current
- Generator Load (%)
- Earth Current
Enclosure Features
- Heavy Duty Steel / Aluminum Structure
- E-Stop on Enclosure
- Control Panel Eliminated from Engine Vibrations
- Standard Sound Attenuation Foam
- Plastic Covered Corrosion Resistant Locks & Hinges
- Internally Mounted Exhaust System with Rain Cap
- Coolant Fill Cap
- Removable Base Frame Lifting Hooks
- Oil & Coolant Drain Ports
- Easy Access for Maintenance
Enclosed Gen-Set Dimensions – Level 1
- Length: 256.1 in
- Width w/o lift hooks: 91.61 in
- Height w/o Silencer: 99.02 in
- Height with Silencer: 129.3 in
- Dry Weight: 22,300 lbs.
Standard Features & Accessories
- UL2200 Certification
- Heavy Duty Steel Base Frame
- PMG
- Engine Jacket Water Heater
- Battery and Battery Rack
- Battery Charger
- Anti Vibration Pads between Engine/Alternator & Base Frame
- Roof-mounted Critical Grade Silencer
- Residential Grade Silencer Set for Open Skid Sets
- Exhaust outlet rain cap and radiator fill cap
- Sound Absorb Foam Material for Enclosure
- Emergency Stop Button
- Oil Drain Valve
- Coolant Drain Valve
- Jacket Water Heater Isolation Valves
- Flex Fuel Lines
- Secondary Lock-off Valve on Baseframe
- Engine Manifold Cover
- Turbocharger Cover
- Protection Covers for Rotating Parts
- Exhaust Insulation Cover
- Enclosure DC Light
- Operations Manual
- 24 Months / 2000 hours Limited Standby Warranty
Optional Accessories
- Main Line CB (3 / 4 Poles – 80% / 100% rated)
- Upsize Alternator
- Anti-condensation Heater
- Voltage Regulation ±0.5% w/MX321 AVR
- Gas Regulator
- NG / LP Auto Changeover Control System
- Low Gas Pressure Alarm
- Low Coolant Level Alarm
- Oil Pan Heater
- Oil Temperature Display on Controller
- Manual Speed Adjust Rheostat
- Manual Voltage Adjust Rheostat
- Remote Annunciator Panel
- Remote Control & Monitoring Panel
- Advanced SMS Messaging
- Control Panel Heater
- Battery Disconnect Switch
- Battery Heater
- Battery Charger 10/20 Amp
- Shunt Trip / Aux Contacts
- Spring Anti-vibration Isolators
- Automatic Transfer Panel (ATS)
- 5 Years / 2000 hours Limited Comprehensive Warranty
Codes & Standards
- Designed and manufactured in a facility certified to ISO9001 standards
- Designed and manufactured in a facility certified to ISO14001:2015 standards
- AKSA Power Generation provides single source responsibility for the generator set & accessories
- Prototype tested and production tested according to the UL test program
- Meets NFPA70, 99, 110, 37 Level 1 when equipped with necessary accessories and installed per NFPA standards
product specifications:
| Specification | Value |
| Model Name | APD-NG650 |
| Engine Make | PSI (Doosan) |
| Engine Model | 32L |
| Alternator Make | Stamford |
| Control Panel Make & Model | DSE 7320 MK II |
| Frequency & Speed | 60Hz, 1800 rpm |
| Enclosure Make & Model | AKSA AUL 96 |
| NG Standby Power | 650 kW |
| LP Gas Standby Power | 420 kW |
| Voltage Options | 208/120V, 240/120V, 480/277V, 600/347V |
| Displacement & Cylinders | 31.8 L / 12 Cylinders |
| Engine Type | V-type, 4 Cycle |
| Engine Speed | 1800 rpm |
| Aspiration | Turbo Charge Air Cooled |
| Compression Ratio | 10.5 : 1 |
| Bore / Stroke | 5.91 in / 5.91 in |
| Governor Type | Electronic |
| Fuel Type | NG, LP Gas / Dual Fuel |
| NG Supply Pipe Size | 3.0" NPTF |
| Maximum EPR Rated Pressure | 6.9 kPa |
| System Voltage (dc) | 24V |
| Battery Qty, Rating | 2 x 143 Ah |
| Radiator Cooling System Type | Closed Circuit |
| Coolant Capacity | 54 gal |
| Cranking Temperature | 176°F |
| Full Open Temperature | 198°F |
| Combustion Air Required | 1390 cfm |
| Air Filter Type | Dry Paper Element |
| Oil Specifications | SAE 15W-40 Low Ash Gas Engine oil, API CD/CF or higher |
| Oil Capacity, Min-Max | 95 – 129 Qts |
| Alternator Standards | BS EN 60034 |
| Control System | PMG |
| A.V.R. | MX321 |
| Voltage Regulation | ±0.5% |
| Insulation System | Class H |
| Protection | IP23 |
| Rated Power Factor | 0.8 |
| Length | 256.1 in |
| Width w/o lift hooks | 91.61 in |
| Height w/o Silencer | 99.02 in |
| Height with Silencer | 129.3 in |
| Dry Weight | 22,300 lbs. |
product related documents:
| Weight | 22300 lbs |
|---|---|
| Dimensions | 256.1 × 91.61 × 99.02 in |
Only logged in customers who have purchased this product may leave a review.





Reviews
There are no reviews yet.