Aksa Gas Generator APD-NG350 (350kW)



Aksa Gas Generator APD-NG350 (350kW)
Call for Price
The AKSA APD-NG350 is an industrial-grade natural gas and propane standby generator set built for reliable emergency power in commercial and industrial applications. Powered by a PSI (Doosan) 14.6L HO engine paired with a Stamford alternator, the unit delivers up to 350 kW of standby power at 60 Hz across multiple voltage configurations. Controlled by a DSE 7320 MK II digital panel offering advanced monitoring and remote connectivity, the APD-NG350 is UL2200 listed and fully compliant with NFPA and EPA stationary emergency standards, making it a dependable choice for mission-critical backup power.
Key Features
- UL2200 certified generator set designed for natural gas (NG) or propane (LP) fuel
- PSI (Doosan) 14.6L HO engine with Stamford HCI444E alternator
- Delivers up to 350 kW standby power at 480/277V, 3-phase, 60Hz
- DSE 7320 MK II digital control panel with four-line LCD display and remote monitoring support
- EPA Certified for Emergency Stationary Applications
- Meets NFPA 70, 99, 110, and 37 Level 1 standards (with fast start kit)
- Manufactured in ISO 9001 and ISO 14001:2015 certified facilities
- Available in open skid or sound-attenuated enclosure configurations (Level 1 & Level 2)
- Includes engine jacket water heater, battery charger, and heavy-duty steel base frame
- Backed by a 24-month / 2,000-hour limited standby warranty
APD-NG350 product details and specifications:
General Characteristics
- Model Name: APD-NG350
- Engine Make: PSI (Doosan)
- Engine Model: 14.6L HO
- Alternator Make: Stamford
- Control Panel Make & Model: DSE 7320
- Frequency & Speed: 60Hz, 1800rpm
- Enclosure Make & Model: AKSA AUL 71A/72A
Genset Rating
- 480/277V, PF 0.8: 350 kW Standby, 526A
- 240/120V, PF 0.8: 320 kW Standby, 963A
- 208/120V, PF 0.8: 320 kW Standby, 1112A
- 600/347V, PF 0.8: 350 kW Standby, 421A
- EPA – Certified for Emergency Stationary Applications
Engine Data
- Manufacturer: PSI
- Model: 14.6L HO
- Displacement & Cylinders: 14.6 L / 8 Cylinders
- Engine Type: V-type, 4 Cycle
- Engine Speed: 1800rpm
- Engine Standby Power NG: 400kW
- Aspiration: Turbo Charge Air Cooled
- Compression Ratio: 10.5 : 1
- Bore / Stroke: 5.04 in / 5.59 in
- Governor Type: Electronic
Electric System
- System Voltage (dc): 24V
- Battery Qty, Rating: 2 x 120Ah
Cooling System
- Radiator Cooling System Type: Closed Circuit
- Coolant Capacity: 31.6 gal
- Cranking Temperature: 159.8°F
- Full Open Temperature: 185°F
Exhaust System
- Type: Water cooled manifold
- Max. Allowable Back Pressure: 10.2 kPa
- Max Turbine Outlet Temperature: 1030°F
- Exhaust Gas Flow at Turbine Outlet Conditions: 2038 cfm
Air Intake System
- Combustion Air Required: 635 cfm
- Max Intake Air Restriction (Clean Element): 1.2 kPa / 5 inH2O
- Air Filter Type: Dry Paper Element
Fuel System
- Fuel Type: Natural Gas
- NG Supply Pipe Size: 2 x 1-1/4" NPT
- Maximum EPR Rated Pressure: 6.9 kPa / 1.0 psi
- Recommended Max Pressure: 2.7 kPa / 10.9 inH2O
- Recommended Min Pressure: 1.7 kPa / 6.8 inH2O
Fuel Consumption
- Standby Power (100%), Natural Gas: 4134 cfh / 117.0 m³/hr
Lubrication System
- Oil Specifications: SAE 15W-40 Low Ash Gas Engine oil, API CD/CF or higher
- Oil Capacity, Min-Max: 26.5 - 32.9 Qts
- Oil Filter: 2, Cartridge
- Min – Max Oil Pressure at Idle Speed (1000rpm): 13 psi – 44 psi / 90 kPa – 300 kPa
Alternator Data
- Manufacturer: Stamford
- Standards: BS EN 60034
- Control System: PMG
- A.V.R.: MX341
- Voltage Regulation: ± 1 %
- Insulation System: Class H
- Protection: IP23
- Rated Power Factor: 0.8
- Stator Winding: Double Layer Concentric
- Winding Pitch: Two Thirds
- Winding Leads: 12
- Telephone Interference: THF < 2 %
- Waveform Distortion: No Load < 1.5 %
- Maximum Over Speed: 2250 rev/min
Controller Data
- Manufacturer: DSE
- Model: 7320 MK II
- Microprocessor controlled, UL & NFPA110 Compatible
- License free PC Software (Non-proprietary Software)
- IP65 rating offers increased resistance to water ingress
- Modules can be integrated to building management systems
- Real time clock provides accurate event log
- Four line back-lit LCD text display
- Five key menu navigation, two wire start/stop at Auto mode
- Front panel editing with PIN protection
- Support up to three remote display modules
- Configurable timers and alarms
- Multiple date and timer scheduler
- Integral PLC editor
- 'Protections disabled' feature
- Load switching (load shedding and dummy load outputs)
- Fully configurable via DSE Configuration Suite PC Software
- SCADA monitoring via DSE Configuration Suite PC Software
- Protection & Instruments: Gen. Voltage, Gen. Frequency, Engine Speed, Oil Pressure, Water Temperature, Battery Voltage, Run Time, Phase Sequence, Power Monitoring (kWh/kVAh/kVArh), Power Factor, Generator Current, Generator Load (%), Earth Current
Battery Charger & Electrical System Data
- Manufacturer: ComAp
- Model: InteliCharger
- Input Voltage: 85V ~ 264V AC
- Output Voltage / Current: 13.8V Float / 4A pk
Jacket Water Heater Data
- Manufacturer: Hotstart
- Model: CTM25210-N00
- Input Voltage: 240V
- Power: 2500W
Open Skid Gen-Set Dimensions
- Length: 158 in
- Width w/o lift hooks: 83 in
- Height: 87 in
- Dry Weight: 10,500 lbs.
Enclosed Gen-Set Dimensions – Level 1
- Length: 206 in
- Width w/o lift hooks: 86 in
- Height: 101 in
- Dry Weight: 14,000 lbs.
- Sound Pressure @ 7 meters: 80 dBA
Enclosed Gen-Set Dimensions – Level 2
- Length: 224.6 in
- Width w/o lift hooks: 86 in
- Height: 101 in
- Dry Weight: 14,500 lbs.
- Sound Pressure @ 7 meters: 77 dBA
Enclosure Features
- Heavy Duty Steel / Aluminum Structure
- E-Stop on Enclosure
- Control Panel Eliminated from Engine Vibrations
- Standard Sound Attenuation Foam
- Plastic Covered Corrosion Resistant Locks & Hinges
- Internally Mounted Exhaust System with Rain Cap
- Coolant Fill Cap
- Removable Base Frame Lifting Hooks
- Oil & Coolant Drain Ports
- Easy Access for Maintenance
Codes & Standards
- Designed and manufactured in a facility certified to ISO9001
- Designed and manufactured in a facility certified to ISO14001:2015
- AKSA Power Generation provides single source responsibility for the generator set & accessories
- Prototype tested and production tested according to the UL test program
- Meets NFPA70, 99, 110, 37 Level 1 when equipped with the necessary accessories and installed per NFPA standards (engine must be equipped with a fast start kit for NFPA110 Level 1 applications)
Standard Features & Accessories
- UL2200 Certification
- Heavy Duty Steel Base Frame
- PMG
- Engine Jacket Water Heater
- Battery and Battery Rack
- Battery Charger
- Anti Vibration Pads between Engine/Alternator & Base Frame
- Critical Grade Silencer Inside Enclosure
- Residential Grade Silencer Set for Open Skid Sets
- Exhaust outlet rain cap and radiator fill cap
- Sound Absorb Foam Material for Enclosure
- Emergency Stop Button
- Oil Drain Valve
- Coolant Drain Valve
- Jacket Water Heater Isolation Valves
- Flex Fuel Lines
- Secondary Lock-off Valve on Baseframe
- Engine Manifold Cover
- Turbocharger Cover
- Protection Covers for Rotating Parts
- Exhaust Insulation Cover
- Enclosure DC Light
- Operations Manual
- 24 Months / 2000 hours Limited Standby Warranty
Optional Accessories
- Main Line CB (3 / 4 Poles – 80% / 100% rated)
- Upsize Alternator
- Anti-condensation Heater
- Voltage Regulation ±0.5% w/MX321 AVR
- Gas Regulator
- NG / LP Auto Changeover Control System
- Low Gas Pressure Alarm
- Low Coolant Level Alarm
- Oil Pan Heater
- Oil Temperature Display on Controller
- Manual Speed Adjust Rheostat
- Manual Voltage Adjust Rheostat
- Remote Annunciator Panel
- Remote Control & Monitoring Panel
- Advanced SMS Messaging
- Control Panel Heater
- Battery Disconnect Switch
- Battery Heater
- Battery Charger 10/20 Amp
- Shunt Trip / Aux Contacts
- Spring Anti-vibration Isolators
- Automatic Transfer Panel (ATS)
- 5 Years / 2000 hours Limited Comprehensive Warranty
product specifications:
| Specification | Value |
| Model Name | APD-NG350 |
| Engine Make | PSI (Doosan) |
| Engine Model | 14.6L HO |
| Alternator Make | Stamford |
| Control Panel Make & Model | DSE 7320 MK II |
| Frequency & Speed | 60Hz, 1800rpm |
| Enclosure Make & Model | AKSA AUL 71A/72A |
| Standby Power (480/277V, 3-Phase, PF 0.8) | 350 kW |
| Standby Current (480/277V) | 526 A |
| Standby Power (240/120V, 3-Phase, PF 0.8) | 320 kW |
| Standby Current (240/120V) | 963 A |
| Standby Power (208/120V, 3-Phase, PF 0.8) | 320 kW |
| Standby Current (208/120V) | 1112 A |
| Standby Power (600/347V, 3-Phase, PF 0.8) | 350 kW |
| Standby Current (600/347V) | 421 A |
| Engine Manufacturer | PSI |
| Displacement & Cylinders | 14.6 L / 8 Cylinders |
| Engine Type | V-type, 4 Cycle |
| Engine Speed | 1800 rpm |
| Engine Standby Power (NG) | 400 kW |
| Aspiration | Turbo Charge Air Cooled |
| Compression Ratio | 10.5 : 1 |
| Bore / Stroke | 5.04 in / 5.59 in |
| Governor Type | Electronic |
| System Voltage (dc) | 24 V |
| Battery Qty, Rating | 2 x 120 Ah |
| Radiator Cooling System Type | Closed Circuit |
| Coolant Capacity | 31.6 gal |
| Cranking Temperature | 159.8 °F |
| Full Open Temperature | 185 °F |
| Exhaust Type | Water cooled manifold |
| Max. Allowable Back Pressure | 10.2 kPa |
| Max Turbine Outlet Temperature | 1030 °F |
| Exhaust Gas Flow at Turbine Outlet Conditions | 2038 cfm |
| Combustion Air Required | 635 cfm |
| Max Intake Air Restriction (Clean Element) | 1.2 kPa / 5 inH2O |
| Air Filter Type | Dry Paper Element |
| Fuel Type | Natural Gas |
| NG Supply Pipe Size | 2 x 1-1/4" NPT |
| Maximum EPR Rated Pressure | 6.9 kPa / 1.0 psi |
| Recommended Max Pressure | 2.7 kPa / 10.9 inH2O |
| Recommended Min Pressure | 1.7 kPa / 6.8 inH2O |
| Fuel Consumption, Standby Power (100%), Natural Gas | 4134 cfh / 117.0 m3/hr |
| Oil Specifications | SAE 15W-40 Low Ash Gas Engine oil, API CD/CF or higher |
| Oil Capacity, Min-Max | 26.5 - 32.9 Qts |
| Oil Filter | 2, Cartridge |
| Min - Max Oil Pressure at Idle Speed (1000rpm) | 13 - 44 psi / 90 - 300 kPa |
| Alternator Manufacturer | Stamford |
| Alternator Standards | BS EN 60034 |
| Control System | PMG |
| A.V.R. | MX341 |
| Voltage Regulation | ± 1 % |
| Insulation System | Class H |
| Protection | IP23 |
| Rated Power Factor | 0.8 |
| Stator Winding | Double Layer Concentric |
| Winding Pitch | Two Thirds |
| Winding Leads | 12 |
| Telephone Interference | THF < 2 % |
| Waveform Distortion | No Load < 1.5 % |
| Maximum Over Speed | 2250 rev/min |
| Controller Manufacturer | DSE |
| Controller Model | 7320 MK II |
| Battery Charger Manufacturer | ComAp |
| Battery Charger Model | InteliCharger |
| Battery Charger Input Voltage | 85V ~ 264V AC |
| Battery Charger Output Voltage / Current | 13.8V Float / 4A pk |
| Jacket Water Heater Manufacturer | Hotstart |
| Jacket Water Heater Model | CTM25210-N00 |
| Jacket Water Heater Input Voltage | 240 V |
| Jacket Water Heater Power | 2500 W |
| Open Skid Length | 158 in |
| Open Skid Width w/o lift hooks | 83 in |
| Open Skid Height | 87 in |
| Open Skid Dry Weight | 10,500 lbs. |
| Enclosed Level 1 Length | 206 in |
| Enclosed Level 1 Width w/o lift hooks | 86 in |
| Enclosed Level 1 Height | 101 in |
| Enclosed Level 1 Dry Weight | 14,000 lbs. |
| Enclosed Level 1 Sound Pressure @ 7 meters | 80 dBA |
| Enclosed Level 2 Length | 224.6 in |
| Enclosed Level 2 Width w/o lift hooks | 86 in |
| Enclosed Level 2 Height | 101 in |
| Enclosed Level 2 Dry Weight | 14,500 lbs. |
| Enclosed Level 2 Sound Pressure @ 7 meters | 77 dBA |
| Certifications | UL2200, ISO9001, ISO14001:2015, NFPA70/99/110/37 Level 1, EPA Stationary Standby |
| Standby Warranty | 24 Months / 2,000 hours Limited Standby Warranty |
product related documents:
| Weight | 14500 lbs |
|---|---|
| Dimensions | 224.6 × 86 × 101 in |
Only logged in customers who have purchased this product may leave a review.





Reviews
There are no reviews yet.