Blue Star JD100-01 (100kWe)

Share this product!

Blue Star JD100-01 (100kWe)

Call for Price

SKU: JD100-01

Blue Star Power Systems 100 kWe Diesel Standby Generator — a rugged, EPA Tier 3 certified power solution built on the John Deere 4045HF285 engine, designed for emergency stationary standby applications with UL 2200 listing and a comprehensive sound-attenuated enclosure. 

Key Features 

  • 100 kWe standby power rating at 1800 RPM, 60 Hz 
  • John Deere 4045HF285 turbocharged 4-cylinder inline engine, 158 HP standby 
  • Configurable voltage: 1-Phase 120/240V or 3-Phase 277/480V 
  • Stamford UCI274F alternator with Stamford AS440 Automatic Voltage Regulator (±1% regulation) 
  • Blue Star DCP7310 microprocessor-based digital control panel with CAN Bus (J1939) communications 
  • Level 2 weather-proof enclosure with sound attenuation foam, powder-coated 14-gauge steel 
  • 200 MPH wind-rated enclosure certified per IBC 2021 and ASCE/SEI 7-16 standards 
  • 72-hour / 750-gallon UL 142 listed double-wall sub-base fuel tank with secondary containment 
  • Critical Grade CPJ Series silencer mounted to engine 
  • Engine block heater 1500W 120VAC rated for -20°F 
  • 400 Amp 2-pole mainline circuit breaker mounted and wired in NEMA 1 enclosure 
  • 12V battery system with BC1206A 12V 6A battery charger 
  • EPA Tier 3 certified; UL 2200 & cUL listed; CSA certified 
  • NFPA 110 Level 1 and Level 2 compliant; Seismic certified to IBC 2021 
  • Factory commercial load test included; 2-year / 2000-hour limited warranty 
  • Vibration isolation mounts; oil drain plumbed to bulkhead fitting in base 
  • Dry single-stage air cleaner; electronic isochronous governor 
  • Standard color: White; custom colors available
Share:
Descripción
Additional Info
Reviews
Descripción

 

JD100-01 product details and specifications:

General 

  • Model: JD100-01 
  • Manufacturer: Blue Star Power Systems 
  • Application: Emergency Stationary Standby 
  • Power Rating: 100 kWe 
  • Frequency: 60 Hz 
  • Speed: 1800 RPM 
  • Fuel Type: Diesel 
  • Unit Color: White (custom colors available) 
  • UL 2200 & cUL Listed; CSA Certified 

Engine 

  • Manufacturer: John Deere 
  • Model: 4045HF285 
  • Type: 4-Cycle, Turbocharged, 4-Cylinder Inline 
  • Displacement: 275 Cu. In. (4.50 L) 
  • Bore x Stroke: 4.19 in. x 5.00 in. 
  • Compression Ratio: 19.0:1 
  • Max HP Standby: 158 HP (118 kW) 
  • Governor: Electronic Isochronous 
  • EPA Certification: Tier 3 
  • Oil Pump & Filter included 
  • Oil Drain Extension plumbed to bulkhead fitting in base 
  • Blower Fan & Fan Drive included 
  • Starter & Alternator included 
  • Flexible Fuel Connector included 

Alternator 

  • Manufacturer: Stamford (Nidec) 
  • Model (1-Phase 240V): UCI274F, 12 Lead Double Delta 
  • Model (3-Phase 208V): UCI274D, 12 Lead Wye 
  • Model (3-Phase 240V): UCI274D, 12 Lead Delta 
  • Model (3-Phase 480V): UCI274C, 12 Lead Wye 
  • Model (3-Phase 600V): UCI274D, 4 Lead Wye 
  • Temperature Rise: 125°C over 40°C Ambient 
  • Configuration: Brushless Single Bearing 
  • Poles: 4 Pole, Rotating Field 
  • 100% of Rated Load in One Step 
  • Maximum Harmonic Content: 5% 
  • Insulation Class: Class H 
  • Voltage Regulation: ±1% 
  • Compliant: NEMA MG 1, IEEE, and ANSI Standards 

Voltage Regulator 

  • Model: Stamford AS440 Automatic Voltage Regulator 
  • Type: Half-wave phase controlled thyristor (SMT design) 
  • Voltage Regulation: ±1% 
  • Thermal Drift: 0.03% per 1°C change in AVR ambient 
  • Soft Start Ramp Time: 3 seconds 
  • External Voltage Adjustment: ±10% with 1k ohm trimmer 
  • AVR Response: 20 ms 
  • Over Excitation Protection Set Point: 65VDC 

Control Panel 

  • Model: Blue Star DCP7310 Microprocessor-Based Digital 
  • Mounted in NEMA 12 Enclosure, facing left from generator end 
  • Communications: CAN Bus (J1939) ECU 
  • Display: 4-Line back-lit LCD, IP65 rated (with gasket) 
  • 8 Programmable Contact Inputs; 10 Contact Outputs 
  • RS485 Communicator Interface; USB Connectivity 
  • Standard Shutdowns: Low Oil Pressure, High Coolant Temp, Overspeed, Overcrank 
  • Emergency Stop Pushbutton; Audible Alarm Buzzer with Silencing Switch 
  • NFPA 110 Level 1 Compatible 
  • cULus Listed, CE Approved 
  • Event Recording (250 events); Windows-Based Software; Multilingual Capability 

Enclosure 

  • Level: Level 2 — Weather Proof with Sound Attenuation Foam 
  • Material: Powder Coated 14 Gauge Steel 
  • Wind Rating: 200 MPH certified per IBC 2021 and ASCE/SEI 7-16 
  • Roof: Pitched for increased structural integrity and improved watershed 
  • Openings: Punched intake with baffle and punched exhaust 
  • Doors: Keyed alike lockable with draw-down latches and stainless steel hinges 
  • Sound Foam: 1.5-inch thick Polydamp Type D Acoustical Foam (PAF) 
  • Base: Formed steel with mounting and lifting holes 
  • Vibration Isolation Mounts included 

Cooling System 

  • Type: Unit Mounted Radiator 
  • Ambient Capacity: 122°F (50°C) 
  • Water Pump Flow Rate: 48.0 GPM 
  • Heat Rejection to Coolant: 3,544 BTUM 
  • System Coolant Capacity: 5.40 gal 
  • Engine Jacket Water Capacity: 2.24 gal 

Exhaust System 

  • Silencer: Critical Grade Compact CPJ Series, mounted to engine 
  • Exhaust Gas Temperature (Stack): 1,076°F (580°C) 
  • Gas Volume at Stack Temp: 805 CFM 
  • Maximum Allowable Exhaust Restriction: 30.0 in. H2O 

Fuel System 

  • Fuel Tank: 72 Hour / 750 Gallon UL 142 Listed Sub-Base 
  • Construction: Double Wall with Secondary Containment Standard 
  • Includes: Supply & Return Connections, Fuel Level Gauge, Fuel Leak Switch, Fill & Vent Plumbing 
  • Tank Options: 24 Hr (250 gal), 48 Hr (500 gal), 72 Hr (750 gal) 
  • Fuel Consumption @ 100% Load: 7.76 gal/hr 
  • Fuel Consumption @ 75% Load: 6.25 gal/hr 
  • Fuel Consumption @ 50% Load: 4.55 gal/hr 

Electrical System 

  • Mainline Breaker: 400 Amp, 2 Pole, 240V, NEMA 1 Enclosure 
  • Battery: 12 Volt System with Rack and Cables 
  • Battery Charger: BC1206A, 12V, 6 Amp — UL 1236 Listed 
  • Jacket Water Heater: 1500W, 120VAC, rated for -20°F, with isolation valves 

Air System 

  • Air Cleaner: Dry Single Stage 
  • Aspirating Air Flow: 288 CFM 
  • Air Flow Required for Radiator-Cooled Unit: 5,829 CFM 

Voltage Configurations 

  • 1-Phase: 120/240V, 60 Hz, 1.0 PF — 417 Amps 
  • 3-Phase 208V: 60 Hz, 0.8 PF — 347 Amps 
  • 3-Phase 240V: 60 Hz, 0.8 PF — 301 Amps 
  • 3-Phase 480V: 60 Hz, 0.8 PF — 151 Amps 
  • 3-Phase 600V: 60 Hz, 0.8 PF — 120 Amps 

Weights & Dimensions 

  • OPU: 90 x 44 x 61 in., 2,750 lbs. 
  • Level 1 Enclosure: 102 x 44 x 66 in., 3,350 lbs. 
  • Level 2 Enclosure: 102 x 44 x 66 in., 3,400 lbs. 
  • Level 3 Enclosure: 132 x 44 x 66 in., 3,575 lbs. 
  • 24 Hr Tank: 90.00 x 44.00 x 94.00 in. (L x W x H) 
  • 48 Hr Tank: 120.00 x 44.00 x 102.00 in. (L x W x H) 
  • 72 Hr Tank: 174.00 x 44.00 x 102.00 in. (L x W x H) 

Sound Data (at 23 ft per ISO 8528-10) 

  • OPU: 78 dBA (No Load) / 82 dBA (Full Load) 
  • Level 1 Enclosure: 75 dBA (No Load) / 78 dBA (Full Load) 
  • Level 2 Enclosure: 72 dBA (No Load) / 74 dBA (Full Load) 
  • Level 3 Enclosure: 66 dBA (No Load) / 68 dBA (Full Load) 

Certifications & Compliance 

  • UL 2200 & cUL Listed 
  • CSA Certified 
  • EPA Tier 3 
  • Seismic Certified to IBC 2021 
  • NFPA 110 Level 1 and Level 2 Compliant 
  • CSA C282 Compliant 

Testing & Warranty 

  • Factory Test: Standard Commercial Testing — alarm shutdowns, voltage settings, block loading to rated kWe and PF 
  • All units tested to cUL, CSA, and NFPA 110 standards 
  • Warranty: 2 Year / 2000 Hour Limited Standby Warranty 

product specifications:

SpecificationValue
GENERAL
ModelJD100-01
ManufacturerBlue Star Power Systems
ApplicationEmergency Stationary Standby
Power Rating100 kWe
Frequency60 Hz
Speed1800 RPM
Voltage (1-Phase)120/240V
Voltage (3-Phase)277/480V
Phase Options1-Phase or 3-Phase (configurable)
Power Factor (1-Phase)1.0
Power Factor (3-Phase)0.8
Unit ColorWhite
ENGINE
Engine ManufacturerJohn Deere
Engine Model4045HF285
Engine Type4-Cycle, Turbocharged, 4-Cylinder Inline
Displacement275 Cu. In. (4.50 L)
Bore x Stroke4.19 in. x 5.00 in.
Compression Ratio19.0:1
Max HP Standby158 HP (118 kW)
GovernorElectronic Isochronous
EPA CertificationTier 3
ALTERNATOR
Generator Model (1-Phase)Stamford UCI274F
Generator Model (3-Phase 480V)Stamford UCI274C
Connection (1-Phase)12 Lead Double Delta
Connection (3-Phase 480V)12 Lead Wye
Temperature Rise125°C Rise Over 40°C Ambient
Voltage RegulatorStamford AS440 Automatic Voltage Regulator
Voltage Regulation±1%
Insulation ClassClass H
CONTROL PANEL
Control Panel ModelBlue Star DCP7310
Panel TypeMicroprocessor-Based Digital
CommunicationsCAN Bus (J1939) ECU
ENCLOSURE
Enclosure LevelLevel 2 (Weather Proof with Foam)
Enclosure MaterialPowder Coated 14 Gauge Steel
Wind Rating200 MPH
Sound Attenuation1.5-inch Polydamp Type D Acoustical Foam
FUEL SYSTEM
Fuel TypeDiesel
Fuel Tank Capacity (72 Hr)750 Gallons
Fuel Tank Standard (72 Hr)UL 142 Listed, Double Wall Secondary Containment
Fuel Consumption @ 100%7.76 gal/hr
Fuel Consumption @ 75%6.25 gal/hr
Fuel Consumption @ 50%4.55 gal/hr
COOLING SYSTEM
Cooling TypeUnit Mounted Radiator
Ambient Radiator Capacity122°F (50°C)
Water Pump Flow Rate48.0 GPM
ELECTRICAL
Mainline Breaker400 Amp, 2 Pole, 240V
Battery System12 Volt with Rack and Cables
Battery Charger12V, 6 Amp BC1206A
Jacket Water Heater1500W, 120VAC, -20°F Rated
CERTIFICATIONS
UL ListingUL 2200 & cUL Listed
CSACSA Certified
EPATier 3
SeismicIBC 2021
NFPANFPA 110 Level 1 & Level 2 Compliant
SOUND DATA (Level 2 Enclosure)
Sound Level - No Load72 dBA
Sound Level - Full Load74 dBA
WARRANTY
Warranty2 Year / 2000 Hour Limited

 

product related documents:

2026 EPA Cert 350haj-tjdxl04-5119-005 JD80-02, JD100-01.pdf

JD100-01 Engine Data Sheet 12-5-23.pdf

JD100-01_SpecSheet.pdf

JD100-01_Drawings.pdf

JD100-01.pdf

Additional Info
Peso3400 lbs
Dimensiones102 × 44 × 66 in
Reviews

Valoraciones

No hay valoraciones aún.

Solo los usuarios registrados que hayan comprado este producto pueden hacer una valoración.

Item añadido al carrito View Cart Checkout
Item added to wishlist View Wishlist
Item removed from wishlist